Læs gratis den danske manual til Klein Tools 60554 (5 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 17 personer og har en gennemsnitlig bedømmelse på 4.7 stjerner ud af 9 anmeldelser. Har du et spørgsmål om Klein Tools 60554, eller vil du spørge andre brugere om produktet?

Side 1/5
P100 HALF-MASK RESPIRATOR FILTER REPLACEMENT INSTRUCTIONS
INSTRUCCIONES PARA REEMPLAZAR EL FILTRO DEL RESPIRADOR DEMEDIACARA P100
INSTRUCTIONS DE REMPLACEMENT DU FILTRE DU DEMI-MASQUE RESPIRATOIREP100
60554
BASED ON: 1390555 Rev 05/23 A
10.016.0639.00.AA
FIG. 3 FIG. 5
FIG. 4 FIG. 6
FIG. 1
FIG. 2
FIG. 7
STORAGE
of 14°F (-10°C) to 10F (40° C). Spare filters should also be stored in a cool dry atmosphere, out of direct sunlight at a
between temperatures of 14°F (-10°C) to 10F (4C). Storage under conditions other than those specified may affec
shelf life.
FILTER INSPECTION & REPLACEMENT
DO NOT WASH FILTERS.
as required.
Each filter pack is individually marked with the month and year of shelf life expiration. Shelf life is 5 years for P10
filters. Filters must be discarded when they reach their expiration date printed on the exterior of the packaging
NOTE: Filters must be selected by a competent person familiar with workplace hazards and their concentration.
Particulate filters must be changed when breathing resistance increases as the filter becomes clogged or as th
application requires
Read instructions before using
104°F
(40°C)
14°F
(-1C)
0 – 95%
R.H.
Temperature range of storage conditions
Year/Month
Expiration date
<95%
R.H.
Humidity range of storage conditions
S – SPECIAL OR CRITICAL USER INSTRUCTIONS
These P100 Half-Mask Respirator(s), sizes S/M (P/N: 60553) or M/L (P/N:60552) used with filter (P/N: 60554), have
been manufactured by Air Filtration Solutions for Klein Tools under TC-84A-9447
WARRANTY
www.kleintools.com/warranty
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street Lincolnshire, IL 60069 1-800-553-4676
customerservice@kleintools.com
www.kleintools.com
ENGLISH
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
GENERAL SPECIFICATIONS
PARTICULATE FILTERS 60554 FOR P100 HALF MASK RESPIRATORS 60552 AND 60553
Filter Type: P100 <0.03% penetration
Color Code: Magenta Text
These filters are designed to fit the P100 Half Mask Respirator only, which is approved as a half-mask respirator in
accordance with NIOSH 42 CFR 84. The P100 filter is part of the approved assembly and only when the above items are
used together is the device approved for occupational applications
APPLICATIONS
The P100 half-mask respirator together with P100 filters give protection against all particulate aerosols; including solid
and liquid particules such as dust, metal fumes, and oil mist. The protection provided by classification P100 also cover
the protection provided by lower class filters. Guidelines for the selection and use may vary between countries, alway
check prior to use to ensure that your selection for the intended application meets national requirements
WARNINGS
To ensure safe operations, follow these instructions. Failure to observe these warnings instructions may result in
sickness or death.
NOT FOR USE
in atmospheres containing less than 19.5% oxygen
NOT FOR USE
in atmospheres immediately dangerous to life or health
DO NOT
exceed maximum use concentrations established by regulatory standards. Failure to properly use and
maintain this product could result in injury or death
Follow the manufacturers Users Instructions for changing cartridges, canisters and/or filters
All approved respirators shall be selected, fitted, used and maintained in accordance with MHSA, OSHA and othe
applicable regulations
NEVER
substitute, modify, add or omit parts. Use only exact replacement parts in the configuration as specified by the
manufacturer.
Refer to users instructions and/or maintenance manuals for information on use and maintenance of these respirators
NIOSH does not evaluate respirators for use as surgical masks.
ALWAYS
conduct a pressure face fit check prior to each use. If the check fails the respirator may be faulty or require
replacement depending on age, frequency of use and replacement of filters
The use of this respirator presupposes exact knowledge of the instructions for use, applicable health and safety
standards, guidelines for selection and use, and appropriate training in matters of personal respiratory protection
Leave the contaminated area immediately if
Dizziness or distress is experienced
You taste or smell contaminants or irritation occurs
Breathing becomes difficult
A defect is discovered in the respirator
Store respirator as per instructions
Before occupational use of this respirator a written respiratory protection program must be implemented meeting al
the local government requirements. In the United States employers must comply with OSHA 29 CFR 1910.134 which
includes medical evaluation, training, and fit testing
FITTING
Always check expiration date is not exceeded before unpacking replacement filter
1.
Rotate the 1/4-Turn Latches on the Respirator Body counterclockwise (FIG. 1).
2.
Remove Grille from Respirator Body by pulling out Sample Port Plug to expose the filters (FIG. 2).
3.
Flex Respirator Body to remove both used filters (FIG. 3).
4.
Slide a new filter into position with all the text facing outwards and right-side up (FIG. 4)
5.
Carefully fit the rest of the filter into the Respirator Body using the channel on the filter and aligning the notches o
the side. To ensure that a good seal is made, the filter should be fully seated into the channel on the outside of th
Respirator Body (FIG. 4).
6.
Repeat Steps 4 & 5 for the other filter. Always replace both filters at the same time and keep a record of the expiration
date.
7.
Place Grille into position by pushing the Exhalation Valve surrounds over the Exhalation Valve on the Respiratory Body
Rotate the1/4-Turn Latches clockwise to secure (FIG. 6).
8.
nsert Sample Port Plug and ensure it is fully seated before use (FIG. 7)