LiftMaster LMRRUL Manual


Læs gratis den danske manual til LiftMaster LMRRUL (16 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 44 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 22.5 anmeldelser. Har du et spørgsmål om LiftMaster LMRRUL, eller vil du spørge andre brugere om produktet?

Side 1/16
Introduction
The LiftMaster® Retro-Refl ective Photoelectric
Sensor provides non-contact monitored entrapment
protection. For use with LiftMaster® UL Listed
gate operators. The sensor is a UL Recognized
Component and meets UL 325 requirements.
Monitored external entrapment protection devices
MUST be installed at each Entrapment Zone. Refer to
gate operator manual for compatibility with LMRRUL
sensor.
Speci cations
Max Range: 50 ft. (15.2 m)
Sensor Dimensions with Hood:
2.29" W x 3.72" H x 2.76" D
Refl ector Dimensions with Hood:
2.61" W x 4.72" H x 2" D
Cable Length: 10 ft. (3 m)
Operating Temperature: -40˚C to 65˚C
(-40˚F a 149˚F)
Outdoor Rating: Nema 4X
Input voltage:
Sensor: Black/red wires 6.8 VDC, 20mA
Heater: Green/white wires 10-40VDC or 8-28 VAC, 2
watts max., 170mA @ 12 VDC/VAC,
85mA@ 24 VDC/VAC
Heater: Thermostatically controlled, NOT
recommended for solar applications
MONITORED RETRO-REFLECTIVE
PHOTOELECTRIC SENSOR
Model LMRRUL
To prevent possible SERIOUS INJURY or DEATH from a closing gate or door:
Read and follow ALL instructions.
Be sure to DISCONNECT ALL POWER to the operator BEFORE installing the photoelectric sensor.
The gate or door MUST be in the fully opened or closed position BEFORE installing the LiftMaster®
Monitored Entrapment Protection device.
Correctly connect and align the photoelectric sensor.
Install the photoelectric sensor so that the center of the sensor window is NO HIGHER than
4-1/2" (11.4cm) above the oor for door operators and 26" (66 cm) above grade for gate operators.
Monitored external entrapment protection devices MUST be installed per the operator installation
manual at each Entrapment Zone.
The sensor and refl ector MUST be mounted vertically.
Use the provided refl ector ONLY.
Test the gate operator and ALL photoelectric sensors monthly. Replace ANY damaged devices.
SAVE THESE INSTRUCTIONS.
WARNING: This product can expose you to chemicals including lead, which are known
to the State of California to cause cancer or birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov.
Installation
IMPORTANT: The sensor and the re ector MUST be mounted vertically. Disconnect ALL power to the
operator.
1. Attach the mounting bracket to the post with 1/4"-20 screws. Drill a hole in the post through the center
hole in the bracket. Optional: If installing to a square post or fl at surface, you may attach the sensor
bracket directly to the post without using the mounting bracket. Make sure the location of the sensor
follows the specifi ed measurements. If installing multiple sensors in close proximity, mount the sensors on
opposite sides to avoid crosstalk.
2. Slide the bottom sensor bracket onto the studs of the mounting bracket and secure with 1/4"-20 lock nuts.
Make sure the bracket legs are facing down.
3. Loosely attach the top sensor bracket with 10-32x1" thread-locking screws. Make sure the slots are
facing up.
4. Place the sensor in the bracket and tighten the screws just enough to allow the sensor to rotate inside the
bracket.
5. Slide the hood over the sensor until it snaps into place. Secure hood with the M3 screw. The hood MUST
be installed on the sensor.
6. Route wires through the center hole of the mounting bracket and into the post. Optional: Use conduit with
NEMA 4X compatible 1/2"-14 NPT fi tting (not provided).
7. Place the refl ector in the refl ector hood.
8. Secure the refl ector and hood to the bracket with 8-32x1" screws. Secure the bottom of the refl ector to the
hood with 8-32x1" screws.
9. Mount the re ector a minimum of 3 ft. (.9 m) and maximum of 50 ft. (15.2 m) away from the sensor.
Carton Inventory
Photoelectric sensor with hood
and bracket
Refl ector with hood and
bracket
Wire cover
Screws 8-32x1" (4)
Lock nuts 8-32 (4)
Screws 8-32x3/8" (2)
Thread-locking screws
10-32x1" (2)
Screws 1/4"-20x1-1/4" (6)
Lock nuts 1/4"-20 (2)
M3 screw (1)
Set screw 10-32x3/8" (1)
Tools Needed
Philips screwdriver
1/8" Allen wrench
7/16" socket
11/32" socket
5/32" Allen key
3/32" Allen key
1
2
3
4
5
6
7
9
8
≤ 5" (12.7 cm)
from gate or wall Optional for
square post
Door operators:
4-1/2" (11.4 cm)
Gate operators:
4" (10.2 cm)-26" (66 cm)
Door operators: 4-1/2" (11.4 cm)
Gate operators: 4" (10.2 cm)-26" (66 cm)
≤ 5" (12.7 cm)
from gate or wall
Illustrations are for reference only; your application may look different.