1
TLS1CARD
TIMER LIGHT STATUS OPTION CARD
The TLS1CARD has different configuration modes that determine how the TLS1CARD will function.
MODE COMPARABLE MODIFICATION DESCRIPTION
90-T1, 90-515774, or RDGRNCARD • 3 relay outputs (R1, R2, and R3) with optional flashing for R1TCP Mode 1
• Adjustable Pre-Warning
• R1 output on during Pre-Warning, while in motion, and at an
undefined stopped position
• R2 output on at fully open and at open mid-stop
• R3 output on while closing only
90-T2 • 3 relay outputs (R1, R2, and R3)TCP Mode 2
• Adjustable Pre-Warning
• R1 output on during Pre-Warning only
• R2 output on at fully open
• R3 output on only when a special input to open has been used to
open the door which does not activate the Timer-to-Close
TCP Mode 3 90-T4 • 3 relay outputs (R1, R2, and R3)
• Adjustable Pre-Warning
• R1 output on during Pre-Warning only
• R2 output on at fully open and at open mid-stop
• R3 output on while in motion
90-RGLFCIR or 90-HDFLASH2 • TCP Mode 4 2 relay outputs (R1, R2) with optional flashing for R1
• Adjustable Pre-Warning
• R1 output on during Pre-Warning and while closing
• R2 output on at fully open
90-T3 • 3 relay outputs (R1, R2, and R3)TCP Mode 5
• Adjustable Pre-Warning
• R1 output on at all times except fully open and fully closed
• R2 output on at fully open
• R3 output on only when a special input to open has been used to
open the door which does not activate the Timer-to-Close
90-L3FLASH • 3 relay outputs (R1, R2, and R3) with optional flashing for R1TC Mode 1
• R1 output on while in motion
• R2 output on at fully open and at open mid-stop
• R3 output on at fully open, open mid-stop, and at an undefined
stopped position
90-42104 This mode allows a second set of external, track mounted limits to act SP Mode 1
as primary or backup for the operator’s open, close, and safety limits.
NOTE: It is not required that all three inputs have a switch connected to
the TLS1CARD. Either the external close, external safety, external open,
or all three may be used.