Mitsubishi PZ-70CSD-E Manual


Læs gratis den danske manual til Mitsubishi PZ-70CSD-E (8 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 21 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 11 anmeldelser. Har du et spørgsmål om Mitsubishi PZ-70CSD-E, eller vil du spørge andre brugere om produktet?

Side 1/8
Eng-1
This CO2 2 sensor optimizes the amount of airow in accordance with the CO concentration within the room, and thus reduces the
fresh air load.
Refer to the specication sheet for applicable Lossnay models.
This manual must be read both fully and carefully before commencing installation procedures; furthermore, the subsequent
installation must be performed correctly and safely in accordance with the instructions given.
After installation, ensure that this manual is given to the customer.
1. Safety Precautions
WARNING Incorrect handling could cause serious injury or death.
- Never modify or repair by yourself.
If the product is modied or inappropriately repaired, electric shock, re, etc. could result. Contact your dealer for repair.
- Do not move or reinstall the product by yourself.
If it is installed improperly, electric shock, re, etc. could result. Contact your dealer or technical representative.
-Usethespeciedcablesforwiringandconnectthemsecurely.Holdthecablessoasnottoapplyexternalforceofthe
cables to the connector.
Improper connection could result in heat generation or re.
-Allelectricalworkmustbeperformedbyalicensedtechnician,accordingtolocalregulationsandtheinstructions
giveninthisInstallationmanual.
- EnsurethatinstallationworkisdonecorrectlyfollowingthisInstallationmanual.Duringtheinstallationwork,the
powersupplytoLossnayunitshallbecuto󰀨.
If it is installed improperly, electric shock, re, etc. could result.
- Close the control cover after installation.
-Donotinstalltheproductinaplacewhereammablegasesmayleak.
If gas should leak or accumulate around the product, re or explosion could result.
- Do not use the product in special environments.
The product could be damaged if it is used in locations subject to large quantities of oil (including machine oil), steam, or sulde gas.
-Donotinstalltheunitinaplacewherethetemperaturerisesabove40˚C(104°F),wherelargeamountsofoil,steam,
organicsolvents,orcorrosivegases,suchassulfuricgas,arepresent,orwhereacidic/alkalinesolutionsorspraysare
used frequently.
These substances can compromise the performance of the unit or cause certain components of the unit to corrode, which can
result in electric shock, malfunctions, smoke, or re.
CAUTION Incorrect handling could cause injury or damage to property or household e󰀨ects.
- Wire so that it does not receive any tension.
Tension could cause wire breakage, heating or re.
-Putonglovesduringinstallation.
Failure to do so could cause injury.
-Donotputstrongshockontheproduct.
It could cause malfunction.
LossnayCO2 Sensor Duct-mounted Type
PZ-70CSD-E
Installation and Instruction Manual
2402876HG4002
Eng-2
2.ExternalDimensions,
IncludedAccessories,
andSpecications
■Includedaccessories
Please conrm that the following accessory parts are included
in the box.
1. sensor unit: x 1 CO2
2. Installation and Instruction Manual: x 1
■Externaldimensions
■Specications
Rated power supply
voltage
5 VDC
(Supplied from the Lossnay)
Power consumption 2 W or less.
Usage environment 0 ˚C to 40 ˚C (32 ˚F to 104 ˚F),
90 % RH or less. (No Cigarette
Smoke or Sulfur and with no dew
condensation)
Measurement accuracy ± (70 + 5% of measurement value)
ppm
Detection range 400 to 2000 ppm
* 1: In the range of 0 ˚C (32 ˚F) or less, CO2 Sensor may not
detect the correct CO Concentration.2
* 2: The sensor measures CO2 concentration of the air owing
the duct. It may be di󰀨erent from the value at hand. In
addition, the measurement accuracy may vary depending
on the usage environment, installation conditions, etc. but
this is not a malfunction.
3. Installation Method
* Refer to the Operation Instructions and Installation
instructions of Lossnay unit.
RVX3 series. Depending on the model of Lossnay or instal-
lation condition, the actual PCB and following diagram can
be upside down.
3.1 Before installation
Be sure to perform installation while the power of the Lossnay unit is O󰀨.
Remove the Lossnay unit control box cover.
Models other than RVXT series
Models RVXT series
3.2 CO sensor installation2
(1) Make holes on the RA (Return air) duct.
Scales of each hole
mm (inch)
Note:
- Make sure to make 3 holes parallel to the ow in the duct.
Black screws
Control box
cover
Control box cover
Black screws
Control cover
Black screws
45 (1 49/64) 45 (1 49/64)
30 (1 3/16)
Air ow direction
for sensor nozzle
2 pilot holes for drilling screws
Unit: mm (inch)
107(4 7/32) 65 (2 9/16)


Produkt Specifikationer

Mærke: Mitsubishi
Kategori: Ikke kategoriseret
Model: PZ-70CSD-E

Har du brug for hjælp?

Hvis du har brug for hjælp til Mitsubishi PZ-70CSD-E stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Mitsubishi Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Rival

Rival CN753-W Manual

15 Juni 2025
Acopa

Acopa 553WSMKE Manual

15 Juni 2025
Atosa

Atosa RDCS-35 Manual

15 Juni 2025
Gourmia

Gourmia GAF692 Manual

15 Juni 2025
Taylor

Taylor 5315856 Manual

15 Juni 2025
Watts

Watts LF8B Manual

15 Juni 2025
Watts

Watts PLT-5 Manual

15 Juni 2025
ToiToiKids

ToiToiKids Fay Manual

15 Juni 2025
Aiphone

Aiphone JP-8Z Manual

15 Juni 2025