Presence timer is " " or sudden
change in the detection area.
Green
The automatic infinite presence
detection is "ON" and the objects or
people enter more than two spot areas.
Green
Orange Wrong wiring.
Wrong (Safety/Activation) output setting.
Both on delay and door cancel function
are "ON".
Check the dipswtich 3, 4, 11.
If the problem still persists, hard-reset the
sensor.(Turn the power OFF and ON again.)
Remove the objects. Or the dipswtich 11.
Check the wires and connector.
Check & Detection area Adjustments.
Check the dipswtich 13 to 15.
Set either function to "OFF".
Check the dipswtich 9,10.
2. Area width adjustment
When adjusting the width adjustment screws, make sure to turn until it clicks otherwise the proper
operation may not be obtained.
NOTE
1 2 3 cannot be eliminated separately, neither can 101112 .
Adjustments
1st to 3rd rows
Narrow
Wide
EliminatedEliminated
1 2 3 10 11 12
4th and 5th rows
Narrow
Wide
EliminatedEliminated
1 2 3 10 11 12
Width adjustment
screws (Left)
Width adjustment
screws (Right)
Front view
2.0
(6'7")
3.0
(9'10")
4.0
(13'2")
4.5
(14'9")
01.0
(3'3")
1.0
(3'3")
2.0
(6'7")
2.0
(6'7")
3.0
(9'10")
3.0
(9'10")
[mm(feet,inch)]
121 2 3 4 5 6 7 8 9 10 11
3. Dipswitch settings
When using more than one sensor close to
each other, set the frequency different for
each sensor.
Frequency
5
6
Setting4Setting3Setting1 Setting2
65 65 65 65
3
4
All rows have the presence detection function.
To enable the presence detection, do not
enter the detection area for 10 s after setting
the timer.
Presence timer
2 s
43
60 s
43
10 min
43 43
Factory default settings
CommentSettingFunction
Dip
switch
No.
Please adjust the sensitivity and the
presence detection timer according to your
risk assessment.
21
Low
21
Middle
21
High
21
S-High
1
Sensitivity
22.5 to 3.5 m 3.0 to 4.0 m 3.5 to 4.5 m 4.0 to 4.5 m
Set the depth rows with dipswitches 7 and 8.
When "2 rows" are selected, the activation
output is disabled.
5 rows
87
4 rows
87
3 rows
87
2 rows
87
7
8
Row adjustment
Presence area
When dipswitch 11 is set to "ON" the automatic
infinite presence detection has priority over this
function.
With dipswitch 12 "1st & 2nd" , presence timer
for 1st & 2nd rows belong to dipswitch 3 and 4.
Presence timer for 3th to 5th row automatically
becomes 2 s. With dipswitch 12 "1st to 5th",
presence timer will be same as all detection
area, set by combining dipswitch 3 and 4.
Simultaneous
output
The activation and safety outputs can be
selected separately.
9 9
OFF ON
10 10
OFF ON
11 11
OFF ON
15 15
OFF ON
12 12
1st to 5th 1st & 2nd
Door cancel
9
10
11
12
13
When dipswitch 9 is "ON" the sensor is less
influenced by the door movement,
i.e. caused by wind.
If the sensor does not detect for 10 s, the 1st
row will be disabled when door cancel function
is "ON".
(The 1st row will be enabled again when there
is detection at other rows.)
With this fuction, 1st row is disabled if
there are no ditection for 10 s.
If a person or vehicle enter the 1st row
without any detection in other rows
(e.g. enter from the other side), it might
cause an accident.
Risk of getting caught
WARNING
Please do not set On delay 2sec. to "ON"
when door cancel function is "ON".
If both are "ON", the sensor does not output
signal unless it detects a person or object
more than 2 s and 1st row is inactive.
If the person or object enter the 1st row,
the sensor does not detect and door never
opens.
Risk of getting caught
WARNING
On delay 2sec.
To avoid unnecessary openings due to
passing objects/persons set dipswitch 10 to
"ON".
The sensor only activates when a person or
object stays in the detection area for more
then 2 s.
When people or objects enter more than 2
spot areas, this function automatically sets
the presence timer to infinity to increase
safety and avoid unwanted door opening due
to sudden change in floor condition.
Automatic infinite
presence detection
NOTE
Activation output
13
N.O.
13
N.C.
14
15
Safety output
14
N.O.
14
N.C.
When dipswitch 15 is set to "ON", both
activation & safety output will operate
simultaneously regardless of detection area.
Dipswitch 16 is not used.
Check the operation in the operation mode according to the chart below.
Checking
Entry
Status
Operation indicator
Outside of
detection area
Stand-by
Green
Entry into
3rd to 5th row
Orange
Entry into
2nd row
Entry into
1st row
Motion/presence detection
Red
Safety
output
Power
OFF
-
None
Activation
output
13
N.O.
13
N.C.
14
N.O.
14
N.C.
Simultaneous
output
15
OFF
Safety
output
Activation
output
Simultaneous
output
15
ON
13
N.O.
13
N.C.
14
N.O.
14
N.C.
1. When turning the power ON, alwayswalk-test the detection area to ensure the proper operation.
2. Do not place any objects that move oremit light in the detection area. (e.g. plant, illumination, etc.)
Inform building owner/operator of the following items
1. Always keep the detection window clean. If dirty, wipe the window with a damp cloth.
Do not use any cleaner/solvent.
2. Do not wash the sensor with water.
3. Do not disassemble, rebuild or repair the sensor yourself, otherwise an electric shock may occur.
4. When the operation indicator is Green blinking, contact your installer or service engineer.
5. Always contact your installer or service engineer when changing the settings.
6. Do not paint the detection window.
WARNING
NOTE
Door operation Operation
indicator Possible cause Possible countermeasures
Troubleshooting
Check the wires and connector.
Set the sensitivity higher.
Set the presence timer longer.
Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Door opens
when no one
is in the
detection area.
(Ghosting)
Door remains
open.
Door does not
open when a
person enters
the detection
area.
Proper
operation
Set to the stated voltage.
Check the wires and connector.
Unstable
Unstable
Proper
Proper
None
Twice
Green
blinking
Slow
Green
Blinking
Wrong wiring or connection failure.
Wrong detection area positioning.
Sensitivity is too low.
Short presence timer.
Dirty detection window.
Wrong power supply voltage.
Wrong wiring or connection failure.
Remove the objects.
Objects that move or emit light in the
detection area.
Check the dipswtich 5, 6.
The detection area overlaps with that
of another sensor.
Use the rain-cover. (Separately available)
Or wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Or install in a place keeping the waterdrops off.
Waterdrops on the detection window.
Adjust the detection area to "Deep" (Outside).
The detection area overlaps with the
door/header.
Set the sensitivity lower.Sensitivity is too high.
Check the wires and connector.Wrong wiring or connection failure.
Adjust the detection area to "Deep" (Outside).
The detection area overlaps with the
door/header.
Remove highly reflecting objects from the detection
area. Or lower the sensitivity. Or change the area
depth angle.
Signal saturation.
Wrong (Safety/Activation) output setting. Check the dipswtich 13 to 15.
Wrong (Safety/Activation) output setting. Check the dipswtich 13 to 15.
Contact your installer or service engineer.Replacement signal.
: Can be eliminated
Contact
5-8-12, Ogoto, Otsu, Shiga, 520-0101 Japan
OPTEX CO., LTD.
Manufacturer
OPTEX (EUROPE) LTD.
Unit 13 Cordwallis Park Clivemont Road SL6 7BU Maidenhead, Berkshire United Kingdom
Legal representative (UK only)
Europe, Middle-East and Africa Subsidiary
OPTEX TECHNOLOGIES B.V.
Henricuskade 17, 2497 NB The Hague, The Netherlands
www.optex-europe.com Tel : +31(0)70 419 41 00
North and South America Subsidiary
OPTEX INCORPORATED
10741 Walker Rd. Suite 300 Cypress, CA 90630 U.S.A
www.optexamerica.com Tel : +1(800)877 6656