Læs gratis den danske manual til PowerWalker VI 800 CSW (4 sider) i kategorien UPS. Denne vejledning er vurderet som hjælpsom af 28 personer og har en gennemsnitlig bedømmelse på 4.7 stjerner ud af 14.5 anmeldelser. Har du et spørgsmål om PowerWalker VI 800 CSW, eller vil du spørge andre brugere om produktet?

Side 1/4
ENGLISH
PowerWalker VI 600-1500 CSW
Quick Guide
I. Overview:
1. LCD display
2. Up/down button
3. Mute button
4. ON / OFF button
5. USB charging port
(5V / 2.1A shared
between 2 ports)
6. USB Communication
port with HID support
7. Surge-protected
outlets (no battery
backup)
8. Battery backup with
surge protected
outlets
9. RJ-45 surge protection
(i.e. for Internet)
10. AC input
11. Ventilation and fan.
12. Circuit breaker (for
French and Schuko)
Surge-protected outlets offer EMI filtering, line conditioning and surge protection,
but they are not supported with backup power from battery in case of AC failure.
II. Operation
Button
Function
ON/OFF
button
Press and hold the On/Off Button for 2 seconds and then release to
change state between Standby (output is off) and Line (output is on).
Mute button
Press and hold the Mute button for 1 second and then release to
mute or unmute the alarm.
Up/down
button
Click to switch displayed information.
ENGLISH
III. Display
State
Display
Meaning
LED
Alarm
Line /
Standby /
Battery
mode
Input voltage, input frequency, battery voltage, battery
Power, Backup time, output voltage, output frequency,
load Power and load percentage.
k: kilo, W: watt, V: voltage, A: ampere, %: percent, degC:
centigrade degree, Hz: frequency, min: minute
Line
Mode
The UPS is connected to AC input.
AVR
Mode
flashing
When the icon is flashing, the UPS is regulating the
voltage (reducing or increasing the voltage).
Battery
Mode
The UPS is running on battery
every
10 s
All Modes
The UPS alarm is disabled.
All Modes
Battery level in ranges 0-24%, 25-49%, 50-74%, and 75-
100%.
Battery
Mode
Low Battery
every
0.5s
every
1s
All Modes
Load level in ranges 0-24%, 25-49%, 50-74% and 75-100%.
All Modes
Indicates overload.
every
0.5s
every
0.5s
All Modes
Battery replacement needed or the battery is not
connected
Contin
uous
every
2s
Fault
Fault code (here: E14). Check troubleshooting for details.
Continu
ous
Warning
Battery voltage is too high (i.e. wrong battery inserted)
every
1.5s


Produkt Specifikationer

Mærke: PowerWalker
Kategori: UPS
Model: VI 800 CSW

Har du brug for hjælp?

Hvis du har brug for hjælp til PowerWalker VI 800 CSW stil et spørgsmål nedenfor, og andre brugere vil svare dig




UPS PowerWalker Manualer

UPS Manualer

Nyeste UPS Manualer

APC

APC RBC150 Manual

2 April 2025
APC

APC RBC151 Manual

2 April 2025
APC

APC RBC145J Manual

29 Marts 2025
APC

APC RBC140J Manual

29 Marts 2025
APC

APC AP9922 Manual

29 Marts 2025
APC

APC RBC148 Manual

29 Marts 2025
Teltonika

Teltonika BAT120 Manual

30 Januar 2025
APC

APC BX1000M Manual

30 Januar 2025
APC

APC BX850 Manual

30 Januar 2025