Roland HP-237R Manual


Læs nedenfor 📖 manual på dansk for Roland HP-237R (5 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 18 personer og blev bedømt med 4.9 stjerner i gennemsnit af 9.5 brugere

Side 1/5
1
DIGITAL PIANO Date: Feb. 1, 2000
Model HP-237 Version: 1.01MIDI Implementation
1. Receive Data
Channel Voice Messages
Note o
Status 2nd byte 3rd byte
8nH kkH vvH
9nH kkH 00H
n = MIDI channel number : 0H-FH (ch.1-ch.16)
kk = note number: 00H-7FH (0-127)
vv = note o velocity : 00H-7FH (0-127)
* The velocity values of Note O messages are ignored.
Note on
Status 2nd byte 3rd byte
9nH kkH vvH
n = MIDI channel number : 0H-FH (ch.1-ch.16)
kk = note number: 00H-7FH (0-127)
vv = note on velocity: 01H-7FH (1-127)
* Note numbers outside the range of 15-113 are transposed to the nearest octave within
this range.
* Transpose function does not aect the recognized note numbers.
Control Change
* The value specied by a Control Change message will not be reset even by a Program
Change, etc.
Data Entry (Controller number 6, 38)
Status 2nd byte 3rd byte
BnH 06H mmH
BnH 26H llH
n = MIDI channel number : 0H-FH (ch.1-ch.16)
mm, ll = the value of the parameter specied by RPN
Volume (Controller number 7)
Status 2nd byte 3rd byte
BnH 07H vvH
n = MIDI channel number : 0H-FH (ch.1-ch.16)
vv = Volume: 00H-7FH (0-127), Initial Value = 7FH (127)
* Received volume messages aect received note event levels, and cannot aect
internal keyboard notes.
Expression (Controller number 11)
Status 2nd byte 3rd byte
BnH 0BH vvH
n = MIDI channel number : 0H-FH (ch.1-ch.16)
vv = Expression : 00H-7FH (0-127), Initial Value = 7FH (127)
* These message can aect only MIDI notes.
Hold 1 (Controller number 64)
Status 2nd byte 3rd byte
BnH 40H vvH
n = MIDI channel number : 0H-FH (ch.1-ch.16)
vv = Control value : 00H-7FH (0-127) 0-63 = OFF, 64-127 = ON
* These message can aect only MIDI notes.
Sostenuto (Controller number 66)
Status 2nd byte 3rd byte
BnH 42H vvH
* These message can aect only MIDI notes.
n=MIDI channel number: 0H-FH (ch.1-ch.16)
vv=Control value: 00H-7FH (0-127) 0-63 = OFF 64-127 = ON
* These message can aect only MIDI notes.
Soft (Controller number 67)
Status 2nd byte 3rd byte
BnH 43H vvH
n=MIDI channel number: 0H-FH (ch.1-ch.16)
vv=Control value: 00H-7FH (0-127) 0-63 = OFF 64-127 = ON
* These message can aect only MIDI notes.
Eect 1 (Reverb Send Level) (Controller number 91)
Status 2nd byte 3rd byte
BnH 5BH vvH
n=MIDI channel number: 0H-FH (ch.1-ch.16)
vv=Control value: 00H-7FH (0-127) 0-63 = OFF 64-127 = ON
Eect 3 (Chorus Send Level) (Controller number 93)
Status 2nd byte 3rd byte
BnH 5DH vvH
n=MIDI channel number: 0H - FH (ch.1 - ch.16)
vv=Control value: 00H - 7FH (0 - 127) 0-63=OFF 64-127=ON
RPN MSB/LSB (Controller number 100, 101)
Status 2nd byte 3rd byte
BnH 65H mmH
BnH 64H llH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
mm = upper byte of parameter number specied by RPN
ll = lower byte of parameter number specied by RPN
* The value specied by RPN will not be reset even by messages such as Program Change
or Reset All Controller.
**RPN**
The RPN (Registered Parameter Number) messages are expanded control changes, and each
function of an RPN is described by the MIDI Standard.
To use these messages, you must rst use RPN MSB and RPN LSB messages to specify the
parameter to be controlled, and then use Data Entry messages to specify the value of the
specied parameter. Once an RPN parameter has been specied, all Data Entry messages
received on that channel will modify the value of that parameter. To prevent accidents, it is
recommended that you set RPN Null (RPN Number = 7FH/7FH) when you have nished
setting the value of the desired parameter.
On the HP-237, RPN can be used to modify the following parameters.
RPN Data entry
MSB LSB MSB LSB Explanation
00H 01H mmH llH Master Fine Tuning
mm, ll: 00 00H - 40 00H - 7F 7FH
(-100 - 0 - +99.99 cents),
Initial Value = 40 00H (±0 cent)
7FH 7FH --- --- RPN null
Set condition where RPN and NRPN are
unspecied. The data entry messages after set
RPN null will be ignored. (No Data entry
messages are required after RPN null).
Settings already made will not change.
mm, ll: ignored
Copyright © 2000 ROLAND CORPORATION
All rights reserved. No part of this publication may be reproduced in any form without the written permission of ROLAND CORPORATION.
2
Program Change
Status 2nd byte
CnH ppH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
pp = Program number: 00H..2CH (prog.1..prog.45)
Received program change message are assigned as follows.
prog. tone
1 Piano 1
2 Piano 2
3 ---
4 Harpsichord
5 Vibraphone
6 Electric Piano 1
7 Electric Piano 2
8 Pipe Organ
9 Strings
10 Piano1 + Piano2
11 Piano1 + Harpsichord
12 Piano1 + Vibraphone
13 Piano1 + Electric Piano1
14 Piano1 + Electric Piano2
15 Piano1 + Pipe Organ
16 Piano1 + Strings
17 Piano2 + Harpsichord
18 Piano2 + Vibraphone
19 Piano2 + Electric Piano1
20 Piano2 + Electric Piano2
21 Piano2 + Pipe Organ
22 Piano2 + Strings
23 Harpsichord + Vibraphone
24 Harpsichord + Electric Piano1
25 Harpsichord + Electric Piano2
26 Harpsichord + Pipe Organ
27 Harpsichord + Strings
28 Vibraphone + Electric Piano1
29 Vibraphone + Electric Piano2
30 Vibraphone + Pipe Organ
31 Vibraphone + Strings
32 Electric Piano1 + Electric Piano2
33 Electric Piano1 + Pipe Organ
34 Electric Piano1 + Strings
35 Electric Piano2 + Pipe Organ
36 Electric Piano2 + Strings
37 Pipe Organ + Strings
38 Piano1 + Acoustic Bass
39 Piano2 + Acoustic Bass
40 Harpsichord + Strings
41 Vibraphone + Acoustic Bass
42 Electric Piano1 + Acoustic Bass
43 Electric Piano2 + Acoustic Bass
44 Harpsichord + Pipe Organ
45 Piano1 + Strings
* 10-37 are in Dual Play mode.
* 38-45 are in Split Play mode.
* Any Program Number other than those listed above that are received by the HP-237 are
ignored.
* After a Program Change message is received, the sound will change beginning with the
next Note-on. Voices already sounding when the Program Change message was received
will not be aected.
Channel Mode Messages
Reset All Controllers (Controller number 121)
Status 2nd byte 3rd byte
BnH 79H 00H
n = MIDI channel number : 0H-FH (ch.1-ch.16)
* When this message is received, the following controllers will be set to their reset
values.
Controller Reset value
Expression 127 (max)
Hold 1 0 (o)
Sostenuto 0(o)
Soft 0(o)
Local Control
Status 2nd byte 3rd byte
BnH 7BH 00H
BnH 7AH vvH
n=MIDI channel number: 0H - FH (ch.1 - ch.16)
vv=Value: 00H, 7FH (0, 127) 0=OFF 127=ON
All Notes O (Controller number 123)
Status 2nd byte 3rd byte
BnH 7BH 00H
n = MIDI channel number : 0H-FH (ch.1-ch.16)
* When All Notes O is received, all notes on the corresponding channel will be turned
o. However if Hold 1 or Sostenuto is ON, the sound will be continued until these are
turned o.
OMNI OFF (Controller number 124)
Status 2nd byte 3rd byte
BnH 7CH 00H
n = MIDI channel number : 0H-FH (ch.1-ch.16)
* The instrument will behave in the same way as it does when an "All Notes O" message
is received. The mode will be OMNI OFF, POLY(Mode 3).
OMNI ON (Controller number 125)
Status 2nd byte 3rd byte
BnH 7DH 00H
n = MIDI channel number : 0H-FH (ch.1-ch.16)
* The instrument will behave in the same way as it does when an "All Notes O" message
is received. The mode will be OMNI ON, POLY(Mode 1).
MONO (Controller number 126)
Status 2nd byte 3rd byte
BnH 7EH mmH
n = MIDI channel number : 0H-FH (ch.1-ch.16)
mm = mono number: 00H-10H (0-16)
* The same processing will be carried out as when All Notes O is received.
POLY (Controller number 127)
Status 2nd byte 3rd byte
BnH 7FH 00H
n = MIDI channel number : 0H-FH (ch.1-ch.16)
* The same processing will be carried out as when All Notes O is received.


Produkt Specifikationer

Mærke: Roland
Kategori: Ikke kategoriseret
Model: HP-237R

Har du brug for hjælp?

Hvis du har brug for hjælp til Roland HP-237R stil et spørgsmål nedenfor, og andre brugere vil svare dig