Læs gratis den danske manual til Roland HP-237R (5 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 20 personer og har en gennemsnitlig bedømmelse på 4.0 stjerner ud af 10.5 anmeldelser. Har du et spørgsmål om Roland HP-237R, eller vil du spørge andre brugere om produktet?

Side 1/5
1
DIGITAL PIANO Date: Feb. 1, 2000
Model HP-237 Version: 1.01MIDI Implementation
1. Receive Data
Channel Voice Messages
Note o
Status 2nd byte 3rd byte
8nH kkH vvH
9nH kkH 00H
n = MIDI channel number : 0H-FH (ch.1-ch.16)
kk = note number: 00H-7FH (0-127)
vv = note o velocity : 00H-7FH (0-127)
* The velocity values of Note O messages are ignored.
Note on
Status 2nd byte 3rd byte
9nH kkH vvH
n = MIDI channel number : 0H-FH (ch.1-ch.16)
kk = note number: 00H-7FH (0-127)
vv = note on velocity: 01H-7FH (1-127)
* Note numbers outside the range of 15-113 are transposed to the nearest octave within
this range.
* Transpose function does not aect the recognized note numbers.
Control Change
* The value specied by a Control Change message will not be reset even by a Program
Change, etc.
Data Entry (Controller number 6, 38)
Status 2nd byte 3rd byte
BnH 06H mmH
BnH 26H llH
n = MIDI channel number : 0H-FH (ch.1-ch.16)
mm, ll = the value of the parameter specied by RPN
Volume (Controller number 7)
Status 2nd byte 3rd byte
BnH 07H vvH
n = MIDI channel number : 0H-FH (ch.1-ch.16)
vv = Volume: 00H-7FH (0-127), Initial Value = 7FH (127)
* Received volume messages aect received note event levels, and cannot aect
internal keyboard notes.
Expression (Controller number 11)
Status 2nd byte 3rd byte
BnH 0BH vvH
n = MIDI channel number : 0H-FH (ch.1-ch.16)
vv = Expression : 00H-7FH (0-127), Initial Value = 7FH (127)
* These message can aect only MIDI notes.
Hold 1 (Controller number 64)
Status 2nd byte 3rd byte
BnH 40H vvH
n = MIDI channel number : 0H-FH (ch.1-ch.16)
vv = Control value : 00H-7FH (0-127) 0-63 = OFF, 64-127 = ON
* These message can aect only MIDI notes.
Sostenuto (Controller number 66)
Status 2nd byte 3rd byte
BnH 42H vvH
* These message can aect only MIDI notes.
n=MIDI channel number: 0H-FH (ch.1-ch.16)
vv=Control value: 00H-7FH (0-127) 0-63 = OFF 64-127 = ON
* These message can aect only MIDI notes.
Soft (Controller number 67)
Status 2nd byte 3rd byte
BnH 43H vvH
n=MIDI channel number: 0H-FH (ch.1-ch.16)
vv=Control value: 00H-7FH (0-127) 0-63 = OFF 64-127 = ON
* These message can aect only MIDI notes.
Eect 1 (Reverb Send Level) (Controller number 91)
Status 2nd byte 3rd byte
BnH 5BH vvH
n=MIDI channel number: 0H-FH (ch.1-ch.16)
vv=Control value: 00H-7FH (0-127) 0-63 = OFF 64-127 = ON
Eect 3 (Chorus Send Level) (Controller number 93)
Status 2nd byte 3rd byte
BnH 5DH vvH
n=MIDI channel number: 0H - FH (ch.1 - ch.16)
vv=Control value: 00H - 7FH (0 - 127) 0-63=OFF 64-127=ON
RPN MSB/LSB (Controller number 100, 101)
Status 2nd byte 3rd byte
BnH 65H mmH
BnH 64H llH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
mm = upper byte of parameter number specied by RPN
ll = lower byte of parameter number specied by RPN
* The value specied by RPN will not be reset even by messages such as Program Change
or Reset All Controller.
**RPN**
The RPN (Registered Parameter Number) messages are expanded control changes, and each
function of an RPN is described by the MIDI Standard.
To use these messages, you must rst use RPN MSB and RPN LSB messages to specify the
parameter to be controlled, and then use Data Entry messages to specify the value of the
specied parameter. Once an RPN parameter has been specied, all Data Entry messages
received on that channel will modify the value of that parameter. To prevent accidents, it is
recommended that you set RPN Null (RPN Number = 7FH/7FH) when you have nished
setting the value of the desired parameter.
On the HP-237, RPN can be used to modify the following parameters.
RPN Data entry
MSB LSB MSB LSB Explanation
00H 01H mmH llH Master Fine Tuning
mm, ll: 00 00H - 40 00H - 7F 7FH
(-100 - 0 - +99.99 cents),
Initial Value = 40 00H (±0 cent)
7FH 7FH --- --- RPN null
Set condition where RPN and NRPN are
unspecied. The data entry messages after set
RPN null will be ignored. (No Data entry
messages are required after RPN null).
Settings already made will not change.
mm, ll: ignored
Copyright © 2000 ROLAND CORPORATION
All rights reserved. No part of this publication may be reproduced in any form without the written permission of ROLAND CORPORATION.
2
Program Change
Status 2nd byte
CnH ppH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
pp = Program number: 00H..2CH (prog.1..prog.45)
Received program change message are assigned as follows.
prog. tone
1 Piano 1
2 Piano 2
3 ---
4 Harpsichord
5 Vibraphone
6 Electric Piano 1
7 Electric Piano 2
8 Pipe Organ
9 Strings
10 Piano1 + Piano2
11 Piano1 + Harpsichord
12 Piano1 + Vibraphone
13 Piano1 + Electric Piano1
14 Piano1 + Electric Piano2
15 Piano1 + Pipe Organ
16 Piano1 + Strings
17 Piano2 + Harpsichord
18 Piano2 + Vibraphone
19 Piano2 + Electric Piano1
20 Piano2 + Electric Piano2
21 Piano2 + Pipe Organ
22 Piano2 + Strings
23 Harpsichord + Vibraphone
24 Harpsichord + Electric Piano1
25 Harpsichord + Electric Piano2
26 Harpsichord + Pipe Organ
27 Harpsichord + Strings
28 Vibraphone + Electric Piano1
29 Vibraphone + Electric Piano2
30 Vibraphone + Pipe Organ
31 Vibraphone + Strings
32 Electric Piano1 + Electric Piano2
33 Electric Piano1 + Pipe Organ
34 Electric Piano1 + Strings
35 Electric Piano2 + Pipe Organ
36 Electric Piano2 + Strings
37 Pipe Organ + Strings
38 Piano1 + Acoustic Bass
39 Piano2 + Acoustic Bass
40 Harpsichord + Strings
41 Vibraphone + Acoustic Bass
42 Electric Piano1 + Acoustic Bass
43 Electric Piano2 + Acoustic Bass
44 Harpsichord + Pipe Organ
45 Piano1 + Strings
* 10-37 are in Dual Play mode.
* 38-45 are in Split Play mode.
* Any Program Number other than those listed above that are received by the HP-237 are
ignored.
* After a Program Change message is received, the sound will change beginning with the
next Note-on. Voices already sounding when the Program Change message was received
will not be aected.
Channel Mode Messages
Reset All Controllers (Controller number 121)
Status 2nd byte 3rd byte
BnH 79H 00H
n = MIDI channel number : 0H-FH (ch.1-ch.16)
* When this message is received, the following controllers will be set to their reset
values.
Controller Reset value
Expression 127 (max)
Hold 1 0 (o)
Sostenuto 0(o)
Soft 0(o)
Local Control
Status 2nd byte 3rd byte
BnH 7BH 00H
BnH 7AH vvH
n=MIDI channel number: 0H - FH (ch.1 - ch.16)
vv=Value: 00H, 7FH (0, 127) 0=OFF 127=ON
All Notes O (Controller number 123)
Status 2nd byte 3rd byte
BnH 7BH 00H
n = MIDI channel number : 0H-FH (ch.1-ch.16)
* When All Notes O is received, all notes on the corresponding channel will be turned
o. However if Hold 1 or Sostenuto is ON, the sound will be continued until these are
turned o.
OMNI OFF (Controller number 124)
Status 2nd byte 3rd byte
BnH 7CH 00H
n = MIDI channel number : 0H-FH (ch.1-ch.16)
* The instrument will behave in the same way as it does when an "All Notes O" message
is received. The mode will be OMNI OFF, POLY(Mode 3).
OMNI ON (Controller number 125)
Status 2nd byte 3rd byte
BnH 7DH 00H
n = MIDI channel number : 0H-FH (ch.1-ch.16)
* The instrument will behave in the same way as it does when an "All Notes O" message
is received. The mode will be OMNI ON, POLY(Mode 1).
MONO (Controller number 126)
Status 2nd byte 3rd byte
BnH 7EH mmH
n = MIDI channel number : 0H-FH (ch.1-ch.16)
mm = mono number: 00H-10H (0-16)
* The same processing will be carried out as when All Notes O is received.
POLY (Controller number 127)
Status 2nd byte 3rd byte
BnH 7FH 00H
n = MIDI channel number : 0H-FH (ch.1-ch.16)
* The same processing will be carried out as when All Notes O is received.


Produkt Specifikationer

Mærke: Roland
Kategori: Ikke kategoriseret
Model: HP-237R

Har du brug for hjælp?

Hvis du har brug for hjælp til Roland HP-237R stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Roland Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

LG

LG ST-G4SN55 Manual

17 August 2025
Alpine

Alpine TMX-R680A Manual

17 August 2025
LG

LG 28LN662VBLB Manual

17 August 2025
Vulcan

Vulcan VPT13 Manual

17 August 2025
Supermicro

Supermicro X14SBHM Manual

17 August 2025
Alpine

Alpine IVA-C800R Manual

17 August 2025
ZyXEL

ZyXEL XGS1935-28 Manual

17 August 2025