Vimar 01867 Manual


Læs gratis den danske manual til Vimar 01867 (4 sider) i kategorien Lysdæmper. Denne vejledning er vurderet som hjælpsom af 11 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 6 anmeldelser. Har du et spørgsmål om Vimar 01867, eller vil du spørge andre brugere om produktet?

Side 1/4
Viale Vicenza, 14 - I 36063 Marostica VI
Tel. +39 0424 488 600 - Fax (Italia) +39 0424 488 188 - Fax (Export) +39 0424 488 709
www.vimar.eu
Istruzioni
Instruction sheet
49400259A0 01 1006
VIMAR - Marostica - Italy
01867
Regolatore 230 V~ per trasformatori elettronici dimmerabili 40-500 VA
a 50 Hz, 40-400 VA a 60 Hz, con morsetto di neutro, funzione MASTER
per 01868, fusibile di protezione, tecnologia MOSFET, installazione su
guida DIN (60715 TH35), occupa 4 moduli da 17,5 mm
Il dispositivo riceve i comandi direttamente dal bus ed è in grado di comandare direttamente il
carico. Pcomandare inoltre fino a 4 regolatori slave 01868.
CARATTERISTICHE
• Tensionenominaledialimentazione:BUS29V
• Assorbimento:10mA
•Potenzadissipata:4W
• Morsetti:
- L fase, carico,Ssincronismo,Nneutro,busTP
• 4modulida17,5mm
 Memorizzazioneallospegnimentodelcarico,dellaregolazioneimpostata(salvointerruzionedirete)
• Accensione graduale(soft start): garantisceun passaggio gradualedallo stato dispento a
quello di massima luminosità; in questo modo contribuisce all’aumento della vita della lam-
pada riducendo lo stress subito dal filamento durante l’accensione a freddo ed evita l’effetto
abbagliante per le persone.
• Spegnimentograduale(softend):garantisceunpassaggiogradualedallostatodimassima
luminosità a quello di spento.
• Possibilitàdiimpostarelaricercadelmassimo.
• FusibileadaltopoterediinterruzionetipoF2,5AH(07050.HF.2.5)incorporato.
 Protezionecontroicortocircuiticonsegnalazionediinterventomediantespialampeggiante.
• Protezionetermicaconsegnalazionediinterventomediantespialampeggiante.
Va utilizzato in luoghi asciutti e non polverosi ad una temperatura compresa tra -5 °C e + 45 °C (da interno).
CARICHI DIMMERABILI
• Trasformatorielettronicidimmerabiliperlampadealogeneinbassissimatensione:
-40-500VA230V~,50Hz(max5art.01860.105oppuremax8art.01860.60);
-40-400VA230V~,60Hz(max4art.01860.105oppuremax7art.01860.60).
ATTENZIONE:Idatidipotenzasoprariportatisonogarantitiadunatemperatura
ambiente di 25°C; ad ogni incremento di 10°C dI tale temperatura, il valore di potenza
deve essere ridotto del 10%.
Dichiarazioni supplementari a cura del costruttore
•Nonadattialcomandodimotori(es.agitatorid’aria,aspiratori).
CONFIGURAZIONE
PER LE OPERAZIONI DI INSTALLAZIONE E CONFIGURAZIONE, VEDERE IL
MANUALE ISTRUZIONI DEL SISTEMA BY-ME ALLEGATO ALLA CENTRALE.
• Blocchifunzionali:1;ilbloccopuòappartenerealmassimoa4gruppi.
• Selezionedelbloccofunzionale(configurazione):durantelacreazionedeigruppi,quandola
centralerichiededipremereilpulsantedeidispositivi:
- premere il pulsante, si accende il led rosso;
- a led rosso acceso, la centrale configura il blocco funzionale; al termine dell’operazione il led
rosso si spegne.
PARAMETRI
• Velocitàdiregolazione:bassa,mediaoalta;
• Ledsemprespentooaccesosoloaregolatoreattivo;
•SegnalazioneLEDregolatore:
-arancioneacceso:normalefunzionamento;
-arancionelampeggiante:dispositivo in cortocircuito, in sovratemperatura o in sovraccarico;
-spento:assenzatensionedialimentazione,collegamento errato oppure carico interrotto (control-
lare il fusibile ed eventualmente sostituirlo con un altro dello stesso tipo).
•SegnalazioneLEDdiconfigurazione:
-accesorosso:fasediconfigurazione;
-accesoverde:asecondadellaconfigurazioneesoltantoconcentrali20510-16950-14510;
-spento:soltantoinpresenzadicentrali20550+01960,01950,01951,01952,01956e01958.
Parametrididefault:attuatoreregolatoreconvelocitàdiregolazionemedia,leddiconfigura-
zione sempre spento.
SCENARI
L’attuatore può appartenere fino a 4 scenari diversi e, per ogni scenario, memorizzare lo stato
da richiamare all’attivazione dello scenario stesso.
REGOLE DI INSTALLAZIONE
• L’installazionedeveessereeffettuataconl’osservanzadelledisposizioniregolantil’installazio-
ne del materiale elettrico in vigore nel paese dove i prodotti sono installati.
• LunghezzamassimadeicavidicollegamentotraregolatoreMASTEReregolatoreSLAVE:100m.
• Lapotenzanominalenondevemaiesseresuperata.
• Sovraccarichi,archielettriciecortocircuitidanneggianoirreparabilmenteilregolatore.Prima
dell’installazione eseguire un’attenta verifica del circuito eliminando le eventuali cause sopra esposte.
• Ilregolatorenonèprovvistodiinterruzionemeccanica nelcircuitoprincipale enonfornisce
quindi separazione galvanica. Il circuito sul lato carico deve essere considerato sempre in tensione.
CONFORMITA’ NORMATIVA
DirettivaBT
DirettivaEMC
NormaEN50428.
230 V~ dimmer for dimmerable electronic transformers 40-500 VA
50Hz, 40-400 VA 60 Hz, with neutral terminal, MASTER function for
01868, protection fuse, MOSFET technology, installation on DIN rail
(60715 TH35), occupies 4 modules of 17.5 mm.
ThedevicereceivescommandsdirectlyfromtheBUSandisabletocontroltheloaddirectly.
It can moreover control up to 4 slave dimmers 01868.
CHARACTERISTICS
• Ratedsupplyvoltage:BUS29V
• Absorption:10mA
•Powerdissipation:4W
• Terminals:
- L phase, load,Ssynchronism,Nneutral,TPbus
• 4modulesof17.5mm
• Lightinglevelissavedwhenturnedoff(unlessthereisablackout)
• Softstart:ensuresgraduallightingfromzerotomaximumbrightness.Thisway thelifeofa
lamp is increased by reducing stress on the filament and prevents light flash.
• Softend:ensuresagradualpassagefromlighttodark.
• Cansetsearchformaximum.
• FusewithhighbreakingcapacitytypeF2,5AH(07050.HF.2.5)incorporated.
• Protectionagainstshort-circuittogetherwithflashingblowoutdetector.
• Overheatingprotectionwithflashingblowoutdetector.
 Itshouldbeusedindry,dust-freeplacesatatemperaturebetween-5°Cand+45°C(indooruse).
CONTROLLED LOADS
• Dimmerableelectronictransformersforextralowvoltagehalogenlamps:
-40-500VA230V~,50Hz(max5art.01860.105ormax8art.01860.60);
-40-400VA230V~,60Hz(max4art.01860.105ormax7art.01860.60).
WARNING:Theabovepowerdataareguaranteedatanambienttemperatureof25°C;for
each increase of 10°C in the ambient temperature, the power value must be reduced by 10%.
Constructor further information
•Notsuitabletocontrolmotors(e.g.ventialtorsandexhaustfans).
CONFIGURATION
FOR THE OPERATIONS OF INSTALLATION AND CONFIGURATION, SEE THE
BY-ME SYSTEM INSTRUCTIONS MANUAL ATTACHED TO THE CONTROL UNIT.
• Functionalblocks:1;theblockcanbelongtoatmost4groups.
• Selecting the functional block (configuration): during group creation, when the control unit
requirespressingthedevicebutton:
- pressthebutton,theredLEDwilllightup;
- with the redLED on, the controlunit will configurethe functional block; at the endof this
operationtheredLEDwillgoout.
PARAMETERS
• Adjustmentspeed:low,mediumorhigh;
• LEDalwaysofforononlywithdimmeron;
•DimmerLEDindicator:
-onorange:normaloperation;
-blinkingorange:deviceshorted,onover-temperatureoroverload;
-off:nosupplyvoltage,incorrectconnectionorbrokenload(checkthefuseandifnecessary
replace it with another one of the same type).
•ConfigurationLEDindicator:
-onred:configurationphase;
-ongreen:dependingontheconfigurationandonlywithcontrolpanels20510-16950-14510;
-off:onlywithcontrolpanels20550+01960,01950,01951,01952,01956and01958.
• Default parameters: dimmer actuator with medium adjustment speed, configuration LED
always off.
SCENES
The actuator can belong to up to 4 different scenes and, for each of them, save the status to
retrieve when activating again.
INSTALLATION RULES
• Installation should be carried out in compliance with the current regulations regarding the
installation of electrical systems in the country where the products are installed.
•MaximumlengthofcablesconnectingMASTERdimmerandSLAVEdimmer:100metres.
• Theratedpowerlevelshouldneverbeexceeded.
• Overloading, power surges and short-circuits may irreparably damage dimmers. Before
installationcheckthecircuitcarefullyandeliminateanyoftheabovecauses.
• The dimmer does not have a mechanical circuit breaker in the main circuit and so is not
galvanically separated. The circuit load should be considered always under voltage.
CONFORMITY.
LV directive
EMC directive
StandardEN50428.


Produkt Specifikationer

Mærke: Vimar
Kategori: Lysdæmper
Model: 01867

Har du brug for hjælp?

Hvis du har brug for hjælp til Vimar 01867 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Lysdæmper Vimar Manualer

Vimar

Vimar 09134.CM Manual

27 August 2025
Vimar

Vimar 20134.B Manual

26 August 2025
Vimar

Vimar 01550.1 Manual

26 August 2025
Vimar

Vimar 09134 Manual

26 August 2025
Vimar

Vimar 20137.N Manual

24 Juli 2025
Vimar

Vimar 19147.M Manual

24 Juli 2025
Vimar

Vimar 19139.M Manual

24 Juli 2025
Vimar

Vimar 20142.N Manual

24 Juli 2025
Vimar

Vimar 14595.0 Manual

26 Juni 2025

Lysdæmper Manualer

Nyeste Lysdæmper Manualer

Theben

Theben DMG 2 T KNX Manual

9 November 2025
Grässlin

Grässlin trim 300 Manual

27 September 2025
Grässlin

Grässlin trim 200 Manual

26 September 2025
AMX

AMX CCD-15APS-1 Manual

15 September 2025
AMX

AMX RDM-3DC Manual

14 September 2025
AMX

AMX RDM-2DC Manual

14 September 2025
EtiamPro

EtiamPro LQC4D-V1 Manual

30 August 2025
Mueller

Mueller 873010 Manual

18 August 2025