Læs gratis den danske manual til Fantini Cosmi OCV1A (5 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 2 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 1.5 anmeldelser. Har du et spørgsmål om Fantini Cosmi OCV1A, eller vil du spørge andre brugere om produktet?

Side 1/5
OCV1A Control Unit Instructions for Use
1. DESCRIPTION
The OCV1A control unit is capable of commanding a motor (or a set of motors) by means of peripheral control units or
additional modules, depending on the wind conditions. The command will be implemented by making use of a switch to
be connected to the control unit.
2. PACKAGE CONTENTS
1 Electronic control unit on a sealed container (IP55)
2 Wind gauge inclusive of cable (length. 2 m)
3 Container wall-mounted support kit
4 Wind gauge supporting bracket
3. COMPATIBILITY
The OCV1A control unit is compatible with:
- a motor;
- an motor’s additional module;
- a peripheral control unit.
4. OPERATION
The OCV1A control unit operates by means of a switch which is connected to the control unit by means of terminals 3
(downward movement – the curtain will open), 4 (common push-button) and 5 (upward movement – the curtain
will close). The switch may be of the stable or push-button type.
In case a wind alarm occurs (wind gauge coming into action) when a stable switch has been left depressed in the
downward movement, the OCV1A control unit will in any case cause the curtain to go up, yet the curtain will go down
again 8 minutes after the alarm is triggered.
CAUTION!
When the alarm is ON, the switch will be fully disabled.
4.1 Operation priority
In the event that several commands are given simultaneously (e.g. curtain opening and wind alarm as well), the priority
will be as follows:
1 wind gauge; 2 switch.
4.2 Adjustments
The wind actuation threshold can be adjusted by means of a
potentiometer available on the board.
The “+” sign corresponds to 35 km/h; the ““ sign corresponds to 1 km/h.
4.3 Installation reset
Upon the first installation, after checking the wind alarm for perfect operation, if the wind gauge is made to turn, the
curtain shall go up when the alarm speed is reached. You may cancel the alarm wait time (8 minutes) by pressing the
Reset button.
4.4 Connection diagrams
To control an electro-mechanical motor, fully adhere to the instructions given in Diagram 1.
Note: Connect a wire between terminals 2 (power supply input) and 7.
The motor common cable shall be connected to terminal 1 (power supply).
R19,5
mm
R67
mm
51 mm
31 mm
95 mm
FANTINI COSMI S.p.A.: VIA DELLOSIO 6 20090 CALEPPIO DI
SETTALA MI
Tel. 02956821 fax 0295307006 E-mail: info@fantinicosmi.it
Technical assistance: supportotecnico@fantinicosmi.it
Connection diagram for one motor Diagram 1
Motor common BUS LINE
5. Commissioning instructions
The OCV1A control unit can be positioned in covered or uncovered civil premises in accordance with the rules and
regulations currently in force for the 230 V switching devices featuring a degree of protection equal to IP55.
How to install the container and the wind gauge
1 Place the OCV1A control unit, near the motor (if possible) or at any other suitable place. Two wall-mounted
supports are available to carry out this operation.
2 Remove the four screws, then make the connection to the board – make sure that every operation has been
carried out correctly prior to applying the voltage.
3 After powering the control unit, place the curtain at the half-travel position, then cause the wind gauge to turn and
verify that the curtain will go up (i.e. close) when the alarm has been triggered. In case the curtain moves in the
opposite direction, reverse the wires at terminals 6 and 8.
4 Secure the wind gauge to the special bracket available and verify that the gauge has been placed in such a perfect
position as to be hit by the wind.
5 Make the wind calibration, then close the cover and tighten down the screws again.
6 The cable inlet shall be positioned at the container bottom.
6. Technical features
Power supply 230 V – 50 Hz a.c.
Working temperature –10° ÷ +60°C
Relay max. capacity 250 Vac – 4 A (cosφ 0.4)
Wind calibration range 1 km/h ÷ 35 km/h
Container material ABS
“ colour Grey
“ dimensions 120 x 80 x 50