Læs gratis den danske manual til Intermatic ETW2CP (12 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 4 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 2.5 anmeldelser. Har du et spørgsmål om Intermatic ETW2CP, eller vil du spørge andre brugere om produktet?

Side 1/12
Intermatic Connect 365-Day
Programmable Smart Wi-Fi Timer
Installation and Setup Instructions
Description
Intermatic ETW2CP and ETW3CP Smart Timers offer a multi-
purpose solution for indoor and outdoor load control
applications. Available in a 2-circuit and 3-circuit conguration,
these controls provide exible 365-day, Astronomic, and
Holiday programming options.
can be controlled using the Intermatic Connect app, available
via Google Play and the App Store. Units can be eld
congured for either single-pole or double-pole applications
and be used for 120-277 VAC. The controls also include
terminal locations for line voltage overrides.
Federal Communications Commission (FCC) Notice for ETW Series Wi-Fi Timers
This device complies with part 15 of the FCC rules. Operation of this device is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) This device must accept any interference, including interference that may cause undesired operation. This equipment
has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful inter ference when the equipment is operated in a commercial environment. This equipment
generates, uses and radiates radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference
to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference that requires the user to correct
at his or her own expense.
MODELS: ETW2CP, ETW3CP
NOTICE
Do NOT touch circuit board components, contact can create a static discharge, which can damage these electronic components.
Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing.
More than one circuit breaker or disconnect switch may be required to de-energize the equipment before servicing.
For plastic enclosures, bonding between conduit connections is not automatic and must be provided as part of the installation.
Installation and/or wiring must be in accordance with National and Local Electrical Code requirements.
Use #14-#8 AWG wires, rated at least 105° C - COPPER conductors ONLY.
If the power disconnect point is out of sight, lock it in the OFF position and tag it to prevent unexpected application power.
Make sure there is no wire insulation under the terminal plate on the time switch connector. Firmly tighten terminal screws.
For outdoor locations or wet locations (rain-tight), conduit hubs that comply with requirements of the UL514B (standard for fitting conduit
and outlet boxes) are to be used.
Do NOT exceed maximum current carrying capacity.
KEEP DOOR CLOSED AT ALL TIMES when not servicing.
Risk of Fire or Electric Shock
WARNING
ETW3CP
Ratings
Electrical Specifications
Operating Voltage 120-277 VAC, 50/60 Hz
Remote Inputs 120-277 VAC, 50/60 Hz
Load Rating (Motor) 1 HP 120 VAC (NO)
2 HP 240 VAC (NO)
FLA 16 A FLA, 96 A LRA, Type 1C @ 120 VAC 50/60 Hz (NO)
15 A FLA, 96 A LRA, Type 1C @ 240 VAC 50/60 Hz (NO)
Power Consumption 7 W
Electronic Ballast 16 A per circuit (NO)
General Purpose
Current Rating
30 A (NO)
10 A (NC) @ 55° C, 5 A (NC) @ 70° C
Impulse Voltage 4000 VAC
Overvoltage Category III
Pollution Degree 3
Operating Temperature -40º C to 70º C
Control Construction Independently Mounted
Enclosure Type Type 3 Indoor/Outdoor Enclosure
Dimensions H x W x D 7 1/2” x 8 7/8” x 3”
Installation
Follow these instructions to install the timer switch.
1. Open the Smart Wi-Fi Timer enclosure door.
2. Choose and remove the selected ½” to ¾” combination knockout(s) from the enclosure.
There are two on the bottom, one on each side and one on the back of the enclosure.
NOTE: If a ¾” knockout is needed, remove the ½” knockout rst, then the ¾” knockout.
3. Place the enclosure in the desired location providing space for the enclosure door to swing open fully.
4. Mount the enclosure using hardware appropriate for the mounting surface (e.g., brick, concrete, drywall). We recommend using
two of the several 5 mm raised mounting locations in the back of the enclosure rather than the single-location hang slot.
(hardware not included) (Figure 1)
LOCKING HASP
1/2", 3/4" DIA KO
(5 PLACES)
4.80"
4.00"
2.56"
Figure 1
5. Use appropriately rated ttings for the installation.
6. Strip ½” off the supply and load wires. Use AWG #14 - #8 copper conductors rated at least 105º C. Torque 10.6 to 15.6 Lb-In.
7. Connect the wires to the proper terminals on the Wi-Fi timer and tighten the screws rmly (See wiring diagram gures A and B).
8. Close enclosure door.
9. Apply power to the time switch.
10. Install ¼” Padlock thru hasp to secure if desired. (lock not included)
11. Device conguration are done using the Intermatic Connect mobile app. (available via the App Store and Google Play)
Wiring Diagrams
Figure A: 3 Circuit - 3xSPDT or 1xDPDT + 1xSPDT, Circuit 1 and Circuit 2 can be paired for DPDT applications
Figure B: 2 Circuit - 2xSPDT or 1xDPDT, Circuit 1 and Circuit 2 can be paired for DPDT applications
Figure C: Example of wiring a photocontrol, occupancy/vacancy sensor, or a single pole switch requiring a neutral.
Note 1: If using 277 VAC for the remote input terminals, Inputs 1 and 3
or Input 2 alone may be used on model ETW3CP
Note 2: For DPDT operations Circuit 1 and Circuit 2 will be paired
Note 3: If using 277 VAC for the remote input terminals,
Input 1 or Input 2 alone may be used on model ETW2CP
Figure A
120-277 VAC (For 277 VAC see note #1)
NC-1
NO-1 COM1
NC-2
COM2NO-2
CIRCUIT 1
OUTPUT 1
(NO)
INPUT 1
INPUT 2
COM3
INPUT 3
NO-3
NC-3
OUTPUT 1
(NC)
OUTPUT 2
(NO)
OUTPUT 3
(NO)
OUTPUT 2
(NC)
OUTPUT 3
(NC)
L1
POWER TO TIMER
L2/N
120/208/240/277 VAC
(AUTO VOLTAGE,
NO JUMPER REQUIRED)
POWER
TIMER
AC IN
SW3SW2SW1
CIRCUIT 2 CIRCUIT 3
REMOTE INPUT 1 L1
REMOTE INPUTS
REMOTE INPUT 1 N/L2
REMOTE INPUT 2 L1
REMOTE INPUT 3 L1
REMOTE INPUT 2 N/L2
REMOTE INPUT 3 N/L2
Figure B
120-277 VAC (For 277 VAC see note #3)
NC-1
NO-1 COM1
NC-2
COM2NO-2
CIRCUIT 1
OUTPUT 1
(NO)
INPUT 1
INPUT 2
OUTPUT 1
(NC)
OUTPUT 2
(NO)
OUTPUT 2
(NC)
L1
POWER TO TIMER
L2/N
120/208/240/277 VAC
(AUTO VOLTAGE,
NO JUMPER REQUIRED)
POWER
TIMER
AC IN
SW2SW1
CIRCUIT 2
REMOTE INPUT 1 L1
REMOTE INPUTS
REMOTE INPUT 1 N/L2
REMOTE INPUT 2 L1
REMOTE INPUT 2 N/L2
Figure C
120-277V
REMOTE INPUT
PHOTO CONTROL
OR OCC SENSOR
WHITE
RED
BLACK
POWER TO
PHOTO CONTROL
OR OCC SENSOR
N/L2
L1


Produkt Specifikationer