Universal dimmer for rail mounting 50-500 W
Light Management
Universal dimmer for rail mounting 50-500 W
Art. No. : UD1255REG
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and
other hazards.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. In so doing, take all the circuit breakers into account, which support dangerous
voltages to the device and or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
The load is not electrically isolated from the mains even when the device is switched off.
Connect all devices and extensions to the same outer conductor. Devices can be
destroyed when connected to different outer conductors.
Fire hazard. For operation with inductive transformers, each transformer must be fused
on the primary side in accordance with the manufacturer's instructions. Only safety
transformers according to EN 61558-2-6 may be used.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1: Device components
(1) Dimmer
(2) LED on/off: Dimmer on/off
(3) Button n
(4) Button o
3 Function
Intended use
- Switching and dimming of incandescent lamps, HV halogen lamps and dimmable inductive
transformers or Tronic transformers with halogen lamps
1/6
82557123
J0082557123 06.04.2017
- Suitable for mixed load up to the specified output (see chapter 6.1. Technical data)
- Installation in distribution boxes on DIN rail according to EN 60715
iNo mixed-load of Tronic and inductive transformers.
Product characteristics
- Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest
- Electronic over-temperature protection
- Connection of more than one extension is possible
- Connection for central extensions
- Switch-on via bulb-preserving soft start
- Power extension through power boosters (see power booster instructions)
- Automatic setting of the dimming principle suitable for the load
Load type Electrical behaviour Dimming principle
Incandescent lamps ohmic Phase cut-off
HV halogen lamps ohmic Phase cut-off
Tronic transformers with
halogen lamps
capacitive Phase cut-off
Dimmable inductive
transformers with halogen
lamps
inductive Phase cut-on
iFlickering of the connected lamps due to undershoot of the specified minimum load or
through centralised pulses from the power stations. These are not device faults.
iBrief flickering upon load detection of ohmic loads. No operation is possible during load
detection.
4 Operation
Operation is performed using the two buttons on the dimmer, 2-wire extension insert (see
chapter 6.3. Accessories) or installation button.
Extensions can be local or central extensions. With a local extension, one dimmer is operated,
while with a central extension several dimmers can be operated simultaneously.
Operation on dimmer or local extension
The functions of the buttons on the dimmer and those of the local 2-wire extension insert are
identical.
Dimmer Extension insert, 2-wire
Button At top of buttonn
Button At bottom of buttono
Buttons and Over entire surface of buttonn o
Switch light
oPress button or button for less than 0.5 seconds.n o
The light is switched on or off using the stored switch-on brightness.
Adjust the brightness
Light is switched on.
oPress the button for longer than 0.5 seconds.n
The light gets brighter up to maximum brightness.
oPress the button for longer than 0.5 seconds.o
Light gets darker to minimum brightness.
2/6
82557123
J0082557123 06.04.2017
Light Management
Universal dimmer for rail mounting 50-500 W


Produkt Specifikationer

Mærke: JUNG
Kategori: Lysdæmper
Model: UD1255REG

Har du brug for hjælp?

Hvis du har brug for hjælp til JUNG UD1255REG stil et spørgsmål nedenfor, og andre brugere vil svare dig




Lysdæmper JUNG Manualer

JUNG

JUNG 1252UDE Manual

3 August 2024
JUNG

JUNG UD1755REG Manual

31 Juli 2024
JUNG

JUNG UD1255REG Manual

31 Juli 2024
JUNG

JUNG 247.07EB Manual

30 Juli 2024
JUNG

JUNG 1724DEB Manual

25 Juli 2024
JUNG

JUNG 1730DD Manual

13 Januar 2024
JUNG

JUNG CD5544.03V Manual

24 November 2023
JUNG

JUNG 1724DM Manual

28 Oktober 2023
JUNG

JUNG 1271LEDDE Manual

17 September 2023
JUNG

JUNG 1731DD Manual

8 September 2023

Lysdæmper Manualer

Nyeste Lysdæmper Manualer