Læs gratis den danske manual til Lowell ACR-SEQ4-1509 (3 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 23 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 12 anmeldelser. Har du et spørgsmål om Lowell ACR-SEQ4-1509, eller vil du spørge andre brugere om produktet?

Side 1/3
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 1606
Model ACR-SEQ4-1509 Rev. 04-30-21 | pg. 1/3
INTERNAL USE ONLY: PN 24208
DESCRIPTION:
Model ACR-SEQ4-1509 power distribution panel with sequencer
features nine NEMA outlets—six switched (controlled by power
switch for sequential activation/deactivation) and three unswitched
(always on). All outlets are clearly marked to assist the integrator
with connections. Color coded LEDs show sequencing status.
This panel can also be activated and deactivated by a remote
switch or alarm system that's connected to the plug-in barrier strip
terminal blocks in the back of the panel.
The compact steel chassis with black powder epoxy nish is
designed to occupy minimal rack space with overall dimensions of
19"W x 9"D x 1.75"H (1U). Termination is via an attached nine foot
power cord with NEMA 5-15P plug.
FEATURES:
Outlets: Unit features a total of nine NEMA outlets, which are
either switched (controlled by switch) or unswitched (always on).
Front Outlet:
NEMA 5-15R (1 unswitched single)
Rear Outlets:
NEMA 5-15R (2 unswitched single, 2 switched single,
2 switched duplex)
Activation & Sequencing:
The front rocker style power switch has momentary contacts
(normally open SPST) plus rear barrier strip termination blocks
for momentary (normally open) remote switches.
The switch initializes a four-step delayed start up sequence,
activating the switched outlets. A green LED ashes while
the unit is powering up and holds steady when the cycle is
complete. The switch also initializes the four-step delayed
shut down sequence, deactivating the switched outlets in
reverse order. A red LED ashes while the unit is powering
down and holds steady when the cycle is complete. Delay
between steps can be adjusted with a screwdriver (0.5–10
seconds).
Connections for External Controls: Plug-in barrier strip terminal
blocks in the rear of the panel allow external controls to activate
and deactivate the switched outlets.
Left Terminal Block—input from Alarm System: Lock On,
Lock Off, and Switch Lock for alarm system or master control
panel.
Right Terminal Block—input from Remote Switch:
Connect switch with momentary closure.
120VAC, 60Hz, 15A, 1800WPower Rating:
EMI/RFI Filter: 19dB@500Hz, 42dB@30MHz
Circuit Breaker Protection: 15A breaker with reset switch
Attached 9-ft. cord with NEMA 5-15P plugPower Cord:
19"W x 9"D x 1.75"H (1U), 10 lbs.Chassis:
Certication: ETL Listed in US/Canada (UL60065)
Country of Origin: Made in the U.S.A. with global components
A&E SPECIFICATIONS:
The rackmount power distribution panel with sequencer shall be
Lowell Model ACR-SEQ4-1509. It shall feature a total of nine (9)
NEMA 5-15R outlets including six (6) switched in rear, two (2)
unswitched in rear, and one (1) unswitched in front. A rocker style
switch on the front panel shall activate the switched outlets in four
steps, and deactivate them in reverse order. The delay between
steps shall be screwdriver adjustable (0.5 to 10 seconds). Color
coded LEDs shall indicate sequencing status. The panel shall have
a power rating of 120VAC, 60Hz, 15A with EMI/RFI ltering. It
shall include a 15A system circuit breaker with reset button. The
19"W x 9"D x 1.75"H (1U) steel chassis shall have a black powder
epoxy nish. Termination shall be via an attached 9 ft. cord with
NEMA 5-15P plug.
AC Power Distribution Panel w/Sequencer: ACR-SEQ4-1509
Rear view
Front view
System
circuit
breaker
NEMA
5-15R single
(unswitched)
Power
status
Power
switch
Sequence
status
Delay
adjust
Made in USA
Power cord
(attached) NEMA
5-15R single
(unswitched)
NEMA
5-15R single
(switched)
Step 2
NEMA
5-15R duplex
(switched)
Step 4
INPUT
from
alarm
system
INPUT
from
remote
switch
NEMA
5-15R single
(unswitched)
NEMA
5-15R single
(switched)
Step 1
NEMA
5-15R duplex
(switched)
Step 3
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 1606
Model ACR-SEQ4-1509 Rev. 04-30-21 | pg. 2/3
INTERNAL USE ONLY: PN 24208
WIRING: Since switch functions are handled by low-voltage, low-current DC signals, almost any type of wire will work (CAT5, mic line,
intercom wire, speaker wire, or phone wire). Shielding is not required but can be used.
Maximum wire distance: 24 ga.=20,000 ft., 22 ga.=31,200 ft., 18 ga.=76,800 ft.
CONNECTIONS for EXTERNAL CONTROLS: Plug-in barrier strip terminal blocks in the rear of the panel allow external controls to
activate and deactivate switched outlets.
LEFT TERMINAL BLOCK – Input from Alarm System:
If required by local building code, facility usage, or the Fire Marshal; system switches can be overridden
and the system controlled by contact closures provided by the re alarm panel or another similarly installed
device. A maintained contact between the ‘Com’ terminal and any of the terminals shown will provide the
following functions. CAUTION: Do not allow alarm system to make more than one of the contacts described
below at the same time—it could cause controller board damage
Lock OFF: A maintained contact between the ‘Com’ terminal and the ‘Lock Off’ terminal will turn the
system off and keep it off regardless of other switch activations. If the system is already off, it will be
kept off.
Lock ON: A maintained contact between the ‘Com’ terminal and the ‘Lock On’ terminal will turn the
system on and keep it on regardless of other switch activations. If the system is already on, it will be
kept on.
Switch Lock: A maintained contact between the ‘Com’ terminal and the ‘Switch Lock’ terminal will lock
the system in its current state, either on or off, regardless of any other switch activations.
RIGHT TERMINAL BLOCK – Input from Remote Switch:
Connect remotely located momentary closure switch(es). Up to ve switches can be utilized.
Alarm System
Interface
Switch
Lock
Lock
ON
Lock
OFF
Com
Remote
Switch(es)
Switch
OFF
Ind.
ON
Ind.
V+
Wiring to momentary switch w/1 LED
requires 3 conductors
Wiring to momentary switch w/2 LEDs
requires 4 conductors


Produkt Specifikationer

Mærke: Lowell
Kategori: Ikke kategoriseret
Model: ACR-SEQ4-1509
Tænd-/slukkontakt: Ja
Vekselstrømsindgangsfrekvens: 60 Hz
Bredde: 482.6 mm
Dybde: 228.6 mm
Højde: 44.45 mm
Vægt: 4535 g
Produktfarve: Sort
LED-indikatorer: Ja
Kabellængde: 2.74 m
Maksimal ydeevne: 1800 W
Strømstik: NEMA 5–15P
Nominel indgangsspænding: 120 V
AC udgange, antal: 9 AC stikkontakt(er)
AC stikkontakt typer: NEMA 5–15R
Rackkapacitet: 1U
Strøm (maks.): 15 A

Har du brug for hjælp?

Hvis du har brug for hjælp til Lowell ACR-SEQ4-1509 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Lowell Manualer

Lowell

Lowell ACR-SEQ4-1509 Manual

11 December 2024
Lowell

Lowell ACS-2014-HW Manual

7 December 2024
Lowell

Lowell ACS-1510-RPC Manual

7 December 2024
Lowell

Lowell RPC-30 Manual

7 December 2024
Lowell

Lowell ACS-2012 Manual

7 December 2024
Lowell

Lowell ACS-2024-2C Manual

7 December 2024
Lowell

Lowell ACS-1524 Manual

7 December 2024
Lowell

Lowell ACS-1507 Manual

7 December 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer