User Manual
specifications
Display: LCD screen with background, max reading of
“1999”
Operating temperature: 0°C - 40°C
(32°F - 104°F)
Operating humidity: <80% RH
Storage temperature: -10°C - 60°C
(14°F - 122°F)
Storage humidity: <70% RH
Sampling updates: 3/mp
Measurement range selection: automatic or manual
Measurement category: Cat III 500V
Power Source: 2x AAA 1.5V battery
Size: 144 x 70 x 32mm
Weight: ~200g (with battery)
Overload Protection and Overvoltage Protection
Auto Turn On/O function
Data Hold Function
s iafety nforMation
To avoid possible electric shock or personal injury, fol-
low these guidelines:
the device from any damage.
cessories (fuses, probes), ensure the good work-
ing condition, to avoid any damage. Do not use
the device with damaged test leads.
electricity and frequency which can generate in-
terference, due to avoid misuse, false measure-
ment, damage or immeasurable values on the
screen.
and for appropriate measurements. If you misuse
the Meter, it cannot work properly in the future.
vapor, or dust.
Meter’s operation in the selected position and en-
sure the connection of the test leads.
measure, set up the switch to the highest meas-
uring value and go backwards until it achieves the
appropriate range.
measuring more than the rated input voltage.
60V dc, or 30V ac. These voltages pose a shock
hazard.
the nger guards.
tions, disconnect test leads from the circuit under
test.
equipment under test, disconnect circuit power
and discharge all high-voltage capacitors before
testing diodes, continuity or resistance.
circuit before connecting the Meter to the circuit.
cator appears on the screen.
the battery door.
and store the Meter in a cool, dry place, and do
not store in highly humid environment.
with the specied ratings: F 200mA/250V, F
10A/250V.
open or does not t closed and xed properly.
1. LCD display
2. SEL – Select button, function selector switch
3. RAN – Range button, manual selection and range
function switch
4. Function switch
5. „A” jack – Input for 10A current measurements
6. NCV LED – Voltage detector function display LED
7. Backlight turn on/o button
8. HOLD – Date Hold button
9. „COM” – common input terminal
10. uA/mA/V /Ω/°C/°F terminal,
(hereafter „V” terminal)
fUnction
HOLD button
Data hold function.To hold the present reading, press
the data hold button for a while. Press the button again
to resume normal operation.
RANGE button
To select auto-range or manual range modes.