Læs gratis den danske manual til Medisana RM 100 (14 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 73 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 37 anmeldelser. Har du et spørgsmål om Medisana RM 100, eller vil du spørge andre brugere om produktet?
Side 1/14

Authorized manufacturer:
Medical Device Branch of Zhangzhou Easepal Industrial Co., Ltd.
4th Floor of Building #7, No.228, Jiaosong Road,
Taiwanese Investment Zone, Zhangzhou, Fujian
2834
Atemschutzmaske | DE
Particle Filtering Half Masks
| EN
Masque respiratoire
| FR
Ademhalingsbeschermingsmasker
| NL
Maschera respiratoria | IT
Mascarilla respiratoria
| ES
Máscara de proteção
| PT
Μάσκα προστασίας αναπνοής | GR
Åndedrettsvern | NO
Mundbind | DK
Andningsskyddsmask
| SE
Hengityssuojain | FI
Ochranná maska
| CZ
Maska chroniąca drogi oddechowe
| PL
Maska za zaščito dihal | SI
Ochranná dýchacia maska
| SK
Légzésvédő maszk |
HU
Zaštitna maska za disanje |
HR
Mască de protecție respiratorie |
RO
Защитна маска за лице |
BG
Kaitsemask | EE
Respirators | LV
Respiratorius
| LT
Защитная маска
|
RU
1x
RM 100
IM_04-2021_Ver.2.1
Standards: EN 149:2001 +A1:2009; R 2016/425
CCQS Certication Service ltd., Block 1 Blanchardstown Corporate Park, Ballycoolin Road, Blanchardstown, Dublin 15, D15 AKK1, Dublin, Ireland, phone: 0035315886920, email: info@ccqs.ie
You can request the complete EU Declaration of Conformity from medisana GmbH, Carl-Schurz-Str. 2, 41460 Neuss, Germany, or you can also download it from the medisana homepage (www.medisana.com).
medisana GmbH
Carl-Schurz-Str. 2,
41460 NEUSS
DEUTSCHLAND

Protection level: FFP2 NR with degree of protection 95 %
Shelf life: intended for single short-term use;
when stored in closed bag: 3 years.
Size (folded): 106,7mm x 155mm
Art. No.: 33333 (VPE 10), 33335 (VPE 5), 33337 (VPE 25)
Storage: dry, <80% humidity, -30°C to +50°C
Benutzerhinweise
Eine Nichtbeachtung der Gebrauchsanweisungen und Warnhinweise
zu dieser Maske kann zu einer Verminderung ihrer Wirksamkeit und
ggf. zu Krankheiten oder Behinderungen führen. Eine Ausfertigung der
Konformitätserklärung liegt jeder handelsüblichen Verpackungsgröße
bei. Wie bei jedem Atemschutzgerät muss der Träger vor der Nutzung
entsprechend geschult werden. Benutzer sollten vor dem Anlegen stets
prüfen, ob die Maske in einem guten Gebrauchszustand sowie frei von
Verunreinigungen, Schäden an den Kopfbändern usw. ist.
Einschränkung
Unter folgenden Umständen dürfen Sie die Atemschutzmaske
nicht benutzen bzw. einen verunreinigten Bereich nicht betreten
bzw. darin bleiben:
1. Die Umgebungsluft enthält weniger als 19,5 % Sauerstoff.
2. Sie riechen oder schmecken den Schadstoff.
3. Zum Schutz gegen Gase oder Dämpfe.
4. Die Schadstoffe oder deren Konzentrationen sind unbekannt
bzw. unmittelbar lebens- oder gesundheitsgefährlich.
5. Beim Sandstrahlen, Farbsprühen und bei
Asbestbehandlungen.
6. Unter explosiver Atmosphäre.
Warnhinweise
Der Kopfbänder-Clip kann Einuss auf die Dichtigkeit der Maske
haben. Ein zu festes Anziehen der Bänder durch den Clip kann zu
einem ungenauen Sitz der Maske führen. Bitte prüfen Sie die
Dichtigkeit der Maske bei angebrachtem Kopfbänder-Clip wie in der
„ANWEISUNGEN ZUM ANLEGEN“ beschrieben nochmals.
1. Diese mit dem Zeichen „NR“ versehene Maske ist zur
einmaligen Verwendung bestimmt.
2. Die vom Hersteller vorgegebene Konguration darf nie
ersetzt bzw. modiziert werden, und es dürfen keine
Komponenten hinzugefügt oder weggelassen werden.
3. Diese Maske hilft beim Schutz vor bestimmten Partikel-
verunreinigungen, verhindert jedoch nicht vollständig das
Risiko auf Ansteckung oder Infektion.
4. Sofern Gesichtshaar unter die Gesichtsversiegelung gerät,
werden die Dichtheitsanforderungen ggf. nicht erfüllt.
5. Wechseln Sie umgehend die Maske, wenn Ihnen das Atmen
schwerfällt oder die Maske beschädigt bzw. deformiert wird.
6. Wechseln Sie die Maske, wenn die Dichtheit über dem
Gesicht nicht erreicht werden kann.
Lagerung
1. Lagern Sie die Maske bei Nichtverwendung in einem dichten
Behälter außerhalb der verunreinigten Bereiche.
2. Bewahren Sie die Maske während des Transports in der
Originalverpackung auf.
User Instructions
Failure to follow the instructions and warning on the use of this
mask during all times of exposure can reduce the effectiveness
of the mask and could result in illness or disability. A copy of
the Declaration of Compliance will be supplied / provided with
every smallest commercially available package. As with any
respiratory device, the wearer must be adequately trained prior
to use. Before use, the wearer should always check the mask is
in good condition - no dirt, no damage to ear loops etc.
Limitation
Do not use the respirator or enter or stay in a contaminated
area under the following circumstances:
1. Atmosphere contains less than 19.5 % oxygen.
2. If you smell or taste contaminant.
3. For protection against gases or vapors.
4. Contaminants or their concentrations are unknown
or immediately dangerous to life or health.
5. For sandblasting, paint-spray operations
and asbestos treatment.
6. In explosive atmospheres.
Warnings
Mask holder clip may have inuence on the leakage of the
mask. Overly tightening of the ear loops through the clip
may lead to inaccurate tting of the mask. Please check
leakage with attached mask holder clip as described in
FITTING INSTRUCTION again.
1. This mask marked “NR” is for single use only.
2. Never substitute, modify, add, or omit parts in
the conguration as specied by the manufacture.
3. This mask helps protect against certain particulate
contaminants but does not completely eliminate exposure
to the risk of contracting disease or infection.
4. It is unlikely that the requirements for leakage will be
achieved if facial hair passes under the face seal.
5. Change the mask immediately if breathing becomes
difcult or the mask becomes damaged or distorted.
6. Change the mask if a proper face seal cannot be achieved.
Storage
1. Store the mask in a sealed container away
from contaminated areas when not use.
2. Store the mask in the original packing during transport.
ANWEISUNGEN
ZUM ANLEGEN
1. Halten Sie die Halbmaske
über die Nase und den
Mund.
2. Ziehen Sie die Kopfbänder
hinter die Ohren und
befestigen Sie die Bänder
hinter dem Kopf mit dem
Kopfbänder-Clip.
3. Passen Sie den Nasenclip
so an, dass er sicher um die
Nase liegt, und schmiegen
Sie die Enden gegen die
Wangen, um eine gute
Dichtheit zu erzeugen.
4. Halten Sie zur Prüfung der
Dichtheit beide Hände über
die Maske, und atmen Sie
kräftig aus. Sofern Luft aus
dem Nasenraum austritt,
drücken Sie den Nasenclip
fester an, bei Luftaustritt an
den Seiten passen Sie die
Kopfbänder an.
5. Wiederholen Sie die
Anpassungen, bis die
Maske dicht ist.
6. Sollte die Maske nicht dicht
sein, betreten Sie nicht den
verunreinigten Bereich, da
ansonsten Ansteckungsge-
fahr besteht.
FITTING INSTRUCTION
1. Hold the particle half mask
in position over the nose
and mouth.
2. Pull the ear loops behind
the ears and attach the two
straps with the clip behind
the head.
3. Ensure the nose clip is
securely moulded around
the nose, resting the ends
against the cheek to obtain
a good seal.
4. To check for proper t, cup
both hands over the mask
and exhale vigorously. If
air leaks around the nose,
tighten the nose clip, if air
leaks around the edge,
reposition the ear loops for
better t.
5. Repeat adjustments until
the mask is sealed properly.
6. If a proper seal cannot be
achieved do not enter the
contaminated area or it may
cause illness.
Schutzstufe: FFP2 NR mit Schutzgrad 95 %
Haltbarkeit: zur einmaligen kurzzeitigen Verwendung vorgesehen;
bei Lagerung im geschlossenen Beutel: 3 Jahre.
Größe (gefaltet): 106,7mm x 155mm
Art. Nr.: 33333 (VPE 10), 33335 (VPE 5), 33337 (VPE 25)
Lagerung: Trocken, <80 % Luftfeuchtigkeit, -30°C bis +50°C
DE EN
Produkt Specifikationer
Mærke: | Medisana |
Kategori: | Ikke kategoriseret |
Model: | RM 100 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Medisana RM 100 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Ikke kategoriseret Medisana Manualer
22 Juni 2025
20 Juni 2025
20 Juni 2025
19 Juni 2025
7 Februar 2025
7 Februar 2025
7 Februar 2025
30 Januar 2025
5 Januar 2025
5 Januar 2025
Ikke kategoriseret Manualer
- Challenge Xtreme
- Lehle
- Esperanza
- ReTrak
- Pylontech
- North Light
- EMSA
- E-ast
- Advanced Network Devices
- Midland
- Wegman
- Stageworx
- Therm-a-Rest
- AVer
- Alpina
Nyeste Ikke kategoriseret Manualer
12 August 2025
12 August 2025
12 August 2025
12 August 2025
12 August 2025
12 August 2025
12 August 2025
12 August 2025
12 August 2025
12 August 2025