Rane CP 62 Manual

Rane Blander CP 62

Læs gratis den danske manual til Rane CP 62 (8 sider) i kategorien Blander. Denne vejledning er vurderet som hjælpsom af 2 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 1.5 anmeldelser. Har du et spørgsmål om Rane CP 62, eller vil du spørge andre brugere om produktet?

Side 1/8
Manual-1
OPERATORS MANUAL CP 62
COMMERCIAL PROCESSOR
QUICK START
This unit packs a lot of features, so lets start by just getting some music running through it. Make all connections
with the power amplifiers off. The CP 62 must be earth grounded for safety and correct operation. Connect a wire to the
grounding screw (near the POWER input jack) to a known earth ground. The CP 62 can drive two zones with separate
program and levels. Zone 1 can be a stereo zone (determined by the MONO/STEREO MODE switch on the rear), well
hook that up next. The zone outputs are fully balanced, so we recommend the use of balanced cables (¼" Tip-Ring-
Sleeve) connectors if cable lengths are kept short (under 10 feet). Connect the CP 62 ZONE 1 LEFT and RIGHT
OUTPUTS to the amplifier inputs. Hook up a CD or tuner to PROGRAM INPUT 1 using a standard stereo RCA cable.
Plug the RS 2 power supply into the red power connector on the back of the CP 62 and its line cord into the AC linethe
PWR LED should come on. Turn both ZONE LEVEL controls fully counter clockwise. Turn the PROGRAM INPUT
LEVEL LINE 1 up to 12 oclock. Now its OK to turn on the amplifer. Slowly turn up ZONE 1 LEVEL. With the CD/
tuner playing, you should hear program coming from the speakers.
Now connect your other sources to the other PROGRAM INPUTS. Select each input with the ZONE 1 PROGRAM
SELECT switch. Adjust individual source levels with the PROGRAM INPUT LEVELS. Adjust zone volume with the
ZONE LEVEL control. Tailor the zone 1 equalizer to your liking. Connect a second amplifer to the ZONE 2 OUTPUT
and run separate programs and levels to another room.
Never connect anything except an Rane RS 2 power supply to the thing that looks like a red telephone jack on
the rear of the CP 62. This is an AC input and requires special attention if you do not have an operational power supply
exactly like the one originally packed with your unit.
Never connect anything except the optional Rane R1 zone assign or R2 source and level remote controls (or
their equivalent) to the things that look like black telephone handset jacks on the rear of the CP 62. These are not
telephone connections.
Manual-2
FRONT PANEL DESCRIPTION
1. MICROPHONE LEVEL control: Adjusts the level for the paging microphone. The initial level is set by the MIC TRIM on
the rear panel so that this control can have the greatest range without distortion or feedback.
2. MICROPHONE DUCKER SENSITIVITY control: Sets the sensitivity at which the microphone signal ducks the program
material for paging purposes. If the ambient background noise level is high this control should be set lower to prevent false
triggers. A microphone with a switch is recommended.
3. PHONE/LINE LEVEL control: Sets the level for the phone system paging or voice line input.
4. PHONE/LINE DUCKER SENSITIVITY control: Sets the sensitivity at which the phone/line signal ducks the program
material for paging purposes. If the ambient background noise level is high this control should be set lower to prevent false
triggers.
5. IN USE LEDS: Indicate the source of the page. Also useful in determining why a pager is locked out due to the priority
page lockout feature. (See PAGING PRIORITY INTERNAL JUMPER OPTION described on page Manual-4.)
6. Front panel ZONE ASSIGN switch: Selects which zone the rear panel selected paging input will be routed to and activate
7. PROGRAM INPUT LEVEL controls: Adjust the relative levels of each of the four program inputs.
8. OVERLOAD LEDS: Indicate overload for the post-EQ, pre-zone signals.
9. PROGRAM SELECT rotary switch: Selects line inputs 1, 2, 3 or the priority/line 4 Input for each zone.
10. ZONE LEVEL control: Independently controls the volume in zone 1 and zone 2.
11. REMOTE CONTROL switch: Disables the front panel PROGRAM SELECT and ZONE LEVEL controls for each zone.
This alsoenables the SOURCE & LEVEL REMOTE jacks on the rear panel for remote control of these functions using the
optional R2 remote control.
12. ZONE 1 stereo graphic equalizer: Adjusts the frequency contour for the stereo zone 1 outputs (±12 dB). When zone 1 is
used in a dual mono mode, both channels receive the same EQ.
13. ZONE 2 mono graphic equalizer: Adjusts the frequency contour for the mono zone 2 output (±12 dB).
14. POWER indicator: Illuminates a warm yellow glow when the CP 62 is connected to an appropriate power source.


Produkt Specifikationer

Mærke: Rane
Kategori: Blander
Model: CP 62

Har du brug for hjælp?

Hvis du har brug for hjælp til Rane CP 62 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Blander Rane Manualer

Rane

Rane CP 62 Manual

20 Juni 2025
Rane

Rane AX 30 Manual

20 Juni 2025
Rane

Rane DA 216 Manual

20 Juni 2025
Rane

Rane RA 27 Manual

20 Juni 2025
Rane

Rane GE 30 Manual

20 Juni 2025
Rane

Rane CP R1 Manual

20 Juni 2025
Rane

Rane DA 26 Manual

20 Juni 2025
Rane

Rane MPE 47 Manual

20 Juni 2025
Rane

Rane FSC 22 Manual

20 Juni 2025

Blander Manualer

Nyeste Blander Manualer

DNA

DNA HLC 10 MK2 Manual

17 Juni 2025
Roland

Roland VR-3 Manual

16 Juni 2025
DNA

DNA EF-MIX 4 Manual

16 Juni 2025
DNA

DNA MIX 4 EQ Manual

16 Juni 2025
DNA

DNA QFX6 Manual

15 Juni 2025
Globe

Globe SP30 Manual

13 Juni 2025
Globe

Globe SP20 Manual

13 Juni 2025
DNA

DNA CM8-DSP Manual

9 Juni 2025
DNA

DNA HLC 14 MK2 Manual

9 Juni 2025