Rane GE 130 Manual

Rane Blander GE 130

Læs gratis den danske manual til Rane GE 130 (4 sider) i kategorien Blander. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.2 stjerner ud af 2 anmeldelser. Har du et spørgsmål om Rane GE 130, eller vil du spørge andre brugere om produktet?

Side 1/4
Manual-1
OPERATORS MANUAL GE 130
GRAPHIC EQUALIZER
GE 130 CONNECTION
When first connecting the GE 130 to other components,
leave the power supply for last. This gives you a chance to
make mistakes and correct them without damaging your
fragile speakers, ears and nerves.
INPUTS
are actively balanced. Each works equally well. Choose
strictly from a required hardware point-of-view, there will be
no performance trade-offs. The wiring convention adheres to
American, British and International standards of pin 2 (+) hot,
pin 3 (–) return, and pin 1 shield. Unbalanced operation
involves using only pin 2 or “+” as signal, and pin 1 as shield
or ground. It is not necessary to short any inputs to ground—
it doesn’t hurt, it’s just not necessary. Use pin 1, or the shell,
for shield ground.
QUICK START
So tell me honestly, do you actually read the manuals or do you just want to connect the thing and go? If you are one
of the “gotta go now” crowd please read this short section. Even if you read slowly so as to savor every syllable, it only
takes a couple of minutes and may save more of your valuable time later. The rest of this manual is dedicated to those who
really want to know all the nitty-gritty details.
Wait a minute before plugging in the power supply. Hopefully the equipment to and from the GE 130 is balanced, with
pin 2 “hot.” From the line level output preceding the GE 130, connect a XLR male connector to the INPUT jack on the rear
of the GE 130. Connect a female XLR connector to the OUTPUT jack on the rear of the GE 130, to the next line level
device in the signal chain.
Now plug in the power supply. The yellow POWER LED should illuminate, and if you have an audio source working
and the rest of the signal chain completed, you will hear audio. With sliders centered and the LEVEL control at 7
(corresponds to about 2 o’clock), depress the BYPASS switch. If any difference in level exists, adjust the LEVEL control
so the same volume exists whether BYPASS is in or out. You now have an expensive jumper wire. Fully utilizing the
capabilities of the GE 130 requires moving some of the sliders, but you already knew that. To make best use of the GE 130,
use some sort of an analyzer to adjust the sliders properly.
Never connect anything except an RS 1 or other approved Rane AC power supply to the thing that looks like a
telephone jack on the rear of the unit. This is an AC supply and requires some special attention if you do not have an
operational power supply exactly like the one that was originally packed with your unit.
OUTPUTS
The Outputs mimic the Inputs. Balanced output requires
using pin 2 or “+”, and pin 3 for the signal ground. It does not
require pin 1 or shield. The signal exists differentially
between the two balanced leads; ground is not involved. For
hum-free systems ground is used only for shielding.
SIGNAL LEVELS
Signal levels from -10 dBV to +4 dBu are considered
normal and within range (at least 20 dB of headroom exists
above these levels). Do not directly connect microphones
into the GE 130. These require a mic preamp.
WEAR PARTS: This product contains no wear parts.
Manual-2
FRONT PANEL DESCRIPTION
POWER indicator illuminates whenever the appropriate power supply is connected to the unit with the correct line
voltage source.
BYPASS switch and indicator: When the bypass switch is in the in position the red BYPASS LED illuminates and the unit
is in the BYPASS mode. In this mode the audio signal is routed directly from the INPUT to the OUTPUT jacks without
passing through any active circuitry (often referred to as hard-wire bypass). Use this switch to compare equalized and
unequalized material. In the event of power failure, the GE 130 automatically goes into BYPASS.
OVERLOAD indicator illuminates if any section of the GE 130 is within 3 dB of clipping. Occasional blinking of this
LED is acceptable, but if it remains on more than intermittently, turn down either the equalizer’s LEVEL control or reduce
the output level of the preceding component to avoid distortion.
LEVEL control sets the Level of the signal coming into the GE 130. Turn this control down if the OVERLOAD LED
lights up steadily (meaning too strong an Input signal). Since actual unity gain depends on varying slider settings (which is
why we have not marked a unity gain position on the front panel), use the BYPASS switch to determine the exact unity gain
position of this LEVEL control by comparing EQ and BYPASS loudness.
Filter Level slide controls: Each of these sliders control the output level of each of the 30 bandpass filters.


Produkt Specifikationer

Mærke: Rane
Kategori: Blander
Model: GE 130

Har du brug for hjælp?

Hvis du har brug for hjælp til Rane GE 130 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Blander Rane Manualer

Rane

Rane MPE 14 Manual

20 Juni 2025
Rane

Rane CP 31 Manual

20 Juni 2025
Rane

Rane MP 2016 Manual

20 Juni 2025
Rane

Rane FVL 22 Manual

19 Juni 2025
Rane

Rane RE 14 Manual

19 Juni 2025
Rane

Rane GQ 15 Manual

19 Juni 2025
Rane

Rane ME 15B Manual

19 Juni 2025
Rane

Rane MC 22 Manual

19 Juni 2025
Rane

Rane DMS 22 Manual

19 Juni 2025
Rane

Rane MH 4 Manual

19 Juni 2025

Blander Manualer

Nyeste Blander Manualer

DNA

DNA HLC 10 MK2 Manual

17 Juni 2025
Roland

Roland VR-3 Manual

16 Juni 2025
DNA

DNA EF-MIX 4 Manual

16 Juni 2025
DNA

DNA MIX 4 EQ Manual

16 Juni 2025
DNA

DNA QFX6 Manual

15 Juni 2025
Globe

Globe SP30 Manual

13 Juni 2025
Globe

Globe SP20 Manual

13 Juni 2025
DNA

DNA CM8-DSP Manual

9 Juni 2025
DNA

DNA HLC 14 MK2 Manual

9 Juni 2025