Rane GE 30 Manual

Rane Blander GE 30

Læs gratis den danske manual til Rane GE 30 (4 sider) i kategorien Blander. Denne vejledning er vurderet som hjælpsom af 2 personer og har en gennemsnitlig bedømmelse på 3.9 stjerner ud af 1.5 anmeldelser. Har du et spørgsmål om Rane GE 30, eller vil du spørge andre brugere om produktet?

Side 1/4
Manual-1
GE 30
GRAPHIC EQUALIZER
OPERATORS MANUAL
GE 30 CONNECTION
When connecting the GE 30 to other components in your
system for the first time, . is will leave the power supply for last
give you a chance to make mistakes and correct them before any
damage is done.
nected for either balanced or unbalanced operation. is product
offers the choice between going in and out of it using either the
3-pin connectors or the handsome black #6 terminal strips with
the finely plated screws. We will describe here the use of the 3-
pin connectors. e terminal strips are connected in parallel and
are used in the same way. Only the names have been changed.
Pin 2 is hot “+”, pin 3 is return “–, and pin 1 is chassis ground.
Balanced inputs require the use of pins 2 and 3. Pin 1 is unnec-
essary unless you are using it for shield ground. For unbalanced
operation, pins 1 and 3 must be shorted together to prevent 6 dB
of gain reduction. Drive pin 2 as hot and the combination of 1
and 3 as ground.
OUTPUTS are balanced as well and follow the same con-
vention as the inputs. ere are some tricky things to be careful
of at the output. If active balanced operation is your preference,
hot “+” and return “–” should be all that is required. It does
not take three wires to conduct a signal from one unit to the
next. Connect the shield to case or chassis ground. Transformer
balanced outputs are connected in the same manner. Active un-
balanced output requires “+” and ground only. Use pins 2 and 1
respectively. In this mode, do not short pins 1 and 3. If, however,
you are using the transformer coupled mode and are running
unbalanced, short pins 1 and 3 or you will get little or no do
output. In case you haven’t noticed, if you plan on throwing the
selector switch very often it’s a good idea to connect everything
in a balanced configuration.
QUICK START
If you are one of those people who think owner’s manuals are included with a product to help absorb shock and vibration during
shipment, you are a lot like we are. is section is for you. You want to fire up your equalizer without wading through a bunch of
stuff in manuals. Great. Read on. We’ll keep it short.
Set the input control to about . is is approximately unity gain in the LEVEL 6 BOOST/CUT CUT-ONLY mode. (In the
mode the level control should be set to for unity gain.) Your sound system should be set up such that gain or loss is not required in 2
the equalizer(s). Set the switch on the rear for the desired operating mode, EQ MODE CUT-ONLY or BOOST/CUT. e LEDs on
the front illuminate, telling you which mode you are in. Set the switch on the rear for the desired output coupling OUTPUT MODE
mode ( or ). Adjust the and ACTIVE TRANSFORMER COUPLED LOW CUT HIGH CUT FILTER controls on the front for
the desired low and high cut frequencies. Full counterclockwise on the control and full clockwise on the LOW CUT HIGH CUT
control essentially defeats these functions.
If you read only this section, we assume you know how to set up an equalizer. So set the sliders where you want them and youre
outta here.
Never connect anything except an RS 1 or other approved Rane AC power supply to the thing that looks like a telephone
jack on the rear of the GE 30. is is an AC input and requires some special attention if you do not have an operational power
supply EXACTLY like the one that was originally packed with your unit. See the full explanation of the power supply requirements
elsewhere in this manual.
WEAR PARTS:is product contains no wear parts.
Manual-2
FRONT PANEL DESCRIPTION
1 POWER switch. Pressing the top half of this switch causes the mechanism contained within to connect power from the remote
power supply to the circuitry of the unit causing it to operate (ON). Pressing the bottom half snaps the switch to the opposite
operating mode (OFF).
2 SIGnal present indicator illuminates green when an input signal greater than -20 dBm is applied to the unit, regardless of the
position of any controls on the unit, including the BYPASS switch.
3 OverLoad indicator glows or flashes red when the signal passing through the unit is within 4dB of the maximum allowable level
at some point in the circuitry.
4 LEVEL sets the Level of the signal coming into the GE 30. Turn this control down if the OVERLOAD LED lights up steadily
(meaning too strong an Input signal). Since actual unity gain depends on varying slider settings (which is why we have not
marked a unity gain position on the front panel), use the BYPASS switch to determine the exact unity gain position of this
LEVEL control by comparing EQ and BYPASS loudness. Full counterclockwise rotation of this control provides full input attenu-
ation (signal off), full clockwise rotation yields a minimum of +6 dB of gain in the BOOST/CUT mode, or a minimum of +20 dB
of gain in the CUT-ONLY mode.
5 Overall BYPASS switch and indicator. Pressing this button to its and locked position provides a complete “hard-wire” bypass in
of all active circuitry in the GE 30, including grounds. e GE 30 automatically switches to the Bypass mode in the event of a
power failure. is insures that should something fail in the power supply of the unit, signal passes to the rest of the system. e
indicator illuminates red when the GE 30 is placed in the Bypass mode via the switch.
6 Equalization controls. ese 60 mm slide controls set the relative level of boost or cut at each 1/3-octave frequency location. e
effect of each control is indicated by one of two calibration scales, the selection of which is denoted by an illuminated yellow LED
located at the top of the CUT-ONLY scale and at the center of the BOOST/CUT scale.
7 LOW CUT filter control rotates in a clockwise direction to increase the frequency of the low filter cutoff. e calibrations on the
front panel indicate the -3 dB point of the filter. Rotating this control to its full counterclockwise position effectively bypasses the
lter.
8 HIGH CUT filter control rotates clockwise to increases the frequency of the high cut filter cutoff. Like the low-cut filter, the
calibrations reflect the -3 dB point of the filter. Full clockwise rotation effectively bypasses the filter.
9 CUT-ONLY indicator illuminates yellow when the EQ MODE select switch on the rear panel is depressed, placing the GE 30 in
its CUT-ONLY mode.
0 BOOST/CUT indicator illuminates yellow, advising the operator that the rear mounted EQ MODE function select switch is in
its OUT position, placing the GE 30 in the + 12 BOOST/ -15 CUT mode.


Produkt Specifikationer

Mærke: Rane
Kategori: Blander
Model: GE 30

Har du brug for hjælp?

Hvis du har brug for hjælp til Rane GE 30 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Blander Rane Manualer

Rane

Rane AX 30 Manual

20 Juni 2025
Rane

Rane DA 216 Manual

20 Juni 2025
Rane

Rane RA 27 Manual

20 Juni 2025
Rane

Rane GE 30 Manual

20 Juni 2025
Rane

Rane CP R1 Manual

20 Juni 2025
Rane

Rane DA 26 Manual

20 Juni 2025
Rane

Rane MPE 47 Manual

20 Juni 2025
Rane

Rane FSC 22 Manual

20 Juni 2025
Rane

Rane ME 15 Manual

20 Juni 2025

Blander Manualer

Nyeste Blander Manualer

DNA

DNA HLC 10 MK2 Manual

17 Juni 2025
Roland

Roland VR-3 Manual

16 Juni 2025
DNA

DNA EF-MIX 4 Manual

16 Juni 2025
DNA

DNA MIX 4 EQ Manual

16 Juni 2025
DNA

DNA QFX6 Manual

15 Juni 2025
Globe

Globe SP30 Manual

13 Juni 2025
Globe

Globe SP20 Manual

13 Juni 2025
DNA

DNA CM8-DSP Manual

9 Juni 2025
DNA

DNA HLC 14 MK2 Manual

9 Juni 2025