Salus DT500RF Manual

Salus Termostat DT500RF

Læs gratis den danske manual til Salus DT500RF (2 sider) i kategorien Termostat. Denne vejledning er vurderet som hjælpsom af 28 personer og har en gennemsnitlig bedømmelse på 4.2 stjerner ud af 14.5 anmeldelser. Har du et spørgsmål om Salus DT500RF, eller vil du spørge andre brugere om produktet?

Side 1/2
DT500, DT500RF
Quick Guide
www.salus-controls.com
DT500/DT500RF is a programmable room thermostat used to control room temperature. Device launching heating system by
shorting terminal blocks, simultaneously informing the action and showing this information on the LCD display. Extended
features allows us to use various operating modes - automatic (time schedules), manual, frost protection or holiday. Before use
please read this manual carefully. Use only AA 1.5 V alkaline batteries in the thermostat.. Place the batteries into the battery
slot located under the cover (see the chapter on the back). Do not use rechargeable batteries.Battery replacement
This product complies with the essential requirements and other relevant provisions of Directives EMC 2014/30/EU,
LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. The full text of the EU Declaration of Conformity is available at the
following internet address: www.saluslegal.com
Introduction
Product compliance
Safety Information
Use in accordance to national and EU regulations . Use the device as intended , keeping it in dry condition.Product for indoor
use only. Installation must be carried out by a qualied person in accordance to national and EU requlations.
Technical specication
DT500 Thermostat DT500RF Thermostat
Thermostat supply 2 x AA alkaline batteries 2 x AA alkaline batteries
Thermostat rating max 5 (3) A -
Outputs Voltage free NC / NO / COM terminals -
Temperature range 5 °C – 35 °C 5 °C – 35 °C
Temperature accuracy 0.1 °C or 0.5 °C 0.1 °C or 0.5 °C
Control algorithm ITLC
SPAN ± 0.25 °C or ± 0.5 °C
ITLC
SPAN ± 0.25 °C or ± 0.5 °C
Radio frequency - 868 MHz
Dimension [mm] 120 x 90 x 29 120 x 90 x 29
DTRX5 Receiver
Receiver supply 230 V AC
Receiver rating max 16 (5) A
Outputs Voltage free NC / NO / COM terminals
Radio frequency 868 MHz
Dimension [mm] 98 x 98 x 25.2
1
2
3
4
5
6
7
8
Button functions
DT500 / DT500RF Thermostat DTRX5 Receiver
109
1. Boost function
2. Manual Mode
3. Frost protection
4. Schedule settings / Back button
5. Increase button
6. Decrease button
7. Conrm button
8. Holiday Mode
LCD Icon Description 1
6
3
8
2
7
4
9
5
10
12
11
14
13
Day of the week
Low battery status
Program indicator
Heating Mode On
Program number
Wireless connection with the
receiver (only for DT500RF)
Temperature measured / set
Frost Protection Mode On
Boost function
Holiday Mode On
Temperature unit
Manual Mode On
Clock
AM / PM
1
2
3
14 111213
4 5
10
9
8
7
6
DT500 Thermostat Terminals description
DTRX5 Receiver Terminals description
Terminal Description
COM Common Terminal
NO Switched Live ON
NC Switched Live OF
Terminal Description
NO Switch Terminal
COM Common Switch Terminal
L, N Power Supply (230 V AC)
Use terminals on
the backplate.
AC 230V
NO
COM
DTRX5
DT500RF
3V
2 X AA
BOILER CONNECTION*
AC 230V
DTRX5
NO
COM
3V
2
X
AA
MAX
16(5)A
DT500RF
AC 230V
DT500
3V
NC
NO
COM
2
X
AA
BOILER CONNECTION*
AC 230V
3V
NC
NO
COM
2
X
AA MAX
5(3)A
DT500
DT500RF Thermostat Wiring Diagram
DT500 Thermostat Wiring Diagram
Programming - automatic mode
Setting the time
1
9
2
10
3
1
4
2
5
3
7
6
4
8
7
5
9
8
6
10
Press , and OK buttons
simultaneously for 3 seconds.
Press OK to conrm.
Press or to select the hour format.
Thermostat will return to the main screen.
Press OK to conrm.
Press the button
to start programming.
In this mode, user can set the schedules for thermostat (temperature setpoints for specific periods of time). T
choose programming mode: 5-2” (business days + weekend) or “24h” (each day separately) using param
Installer mode. Programmed schedules should use all time periods.
Press or to set the hour.
Use the or button to select
day/days from which you want to start
programming.
Press OK to conrm.
Press OK to conrm.
Press OK to conrm.
Press or to set the minutes.
Use the or button to set
the hour to start the program #1.
Use the or button to set
the temperature for program #1.
Press OK to conrm.
Press OK to conrm.
Press OK to conrm.
Press or to set day of the week.
Use the or button to set
the minutes to start the program #1.
Follow steps 4-9,
to define programs 2-6.
Press OK button to end programming.
OR
3 sec
3 sec
3 sec
Issue Date: May 2022
V04
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change
specication, design and materials of products listed in this brochure without prior notice.
SALUS Controls
Units 8-10, Northeld Business Park
Forge Way, Parkgate,
Rotherham, S60 1SD
Email: sales@salus-tech.com
9. When in manual mode, ON will turn the boiler on
When in manual mode, OFF will turn the boiler o
10. Receiver operates in automatic mode according to
the thermostat/Receiver output is controlled by the
On/O slide switch.


Produkt Specifikationer

Mærke: Salus
Kategori: Termostat
Model: DT500RF

Har du brug for hjælp?

Hvis du har brug for hjælp til Salus DT500RF stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termostat Salus Manualer

Salus

Salus SQ610B Manual

28 August 2025
Salus

Salus SQ605RF Manual

30 Juli 2025
Salus

Salus 091PRO Manual

29 Juli 2025
Salus

Salus RT310SPE Manual

24 Juli 2025
Salus

Salus RT20 Manual

23 Juli 2025
Salus

Salus EL600F Manual

23 Juli 2025
Salus

Salus VS35B Manual

23 Juli 2025
Salus

Salus 091PRORF Manual

23 Juli 2025
Salus

Salus HTRP24 Manual

23 Juli 2025
Salus

Salus CB500X Manual

23 Juli 2025

Termostat Manualer

Nyeste Termostat Manualer

Vimar

Vimar 30811.B Manual

9 November 2025
Vimar

Vimar 02974.N Manual

9 November 2025
Bosch

Bosch BCC110 Manual

8 November 2025
Vimar

Vimar 30811.G Manual

8 November 2025
Warmup

Warmup 7iE Matter Manual

7 November 2025
Vimar

Vimar 30811.C Manual

31 Oktober 2025
Delta Dore

Delta Dore Tybox 137 Manual

17 Oktober 2025