Salus MD22S Manual


Læs gratis den danske manual til Salus MD22S (2 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 21 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 11 anmeldelser. Har du et spørgsmål om Salus MD22S, eller vil du spørge andre brugere om produktet?

Side 1/2
Instruction Manual
22mm in-line Magnetic Filter
Model: MD22S
www.salus-controls.com
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS Controls plc reserve the right
to change specification, design and materials of products listed in this brochure without prior
notice.
Head Office:
SALUS Controls
Units 8-10, Northfield Business
Park, Forge Way, Parkgate
Rotherham, S60 1SD
Email: sales@salus-tech.com
www.salus-controls.com
Issued: July 2021
V007
The following instructions are designed to help the engineer to install
and maintain the Magnetic Filter safely and eciently and should be
followed and adhered to at all times. Make sure there is a water-lling
pipeline behind the lter. During maintenance, check whether the lid
seals are worn or damaged. The best practice is to replace the lid seal at
each repair.
The Magnetic Filter is specially designed for central heating systems. It can
remove almost all the harmful black suspended iron oxide particles accumulated
in the central heating system and protect the complete central heating system.
The lter can be installed in a variety of ways, for example: be installed at any
location on the main pipeline. However, it is recommended to be installed
after the last radiator and before the boiler on the primary return pipework for
maximum protection and eciency.
Note: It is important to have adequate access for maintenance and
servicing when determining a suitable installation location.
1 Air vent valve
2 Magnet bar
3 Drain valve
4 Inlet valve
5 Outlet valve
Open vented system
Figure 2
Combination/Sealed system
Figure 1
1. INTRODUCTION
3. STRUCTURE INTRODUCTION
2. MOUNTING RECOMMENDATIONS
Recommended installation location
RETURN
Boiler
RETURN
Boiler
Pump
Header Tank
Vent
Pipe
2
1
3
4
5


Produkt Specifikationer

Mærke: Salus
Kategori: Ikke kategoriseret
Model: MD22S

Har du brug for hjælp?

Hvis du har brug for hjælp til Salus MD22S stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Salus Manualer

Salus

Salus LX1 Manual

1 Oktober 2025
Salus

Salus T30NC Manual

25 August 2025
Salus

Salus KL08RF 24V Manual

13 August 2025
Salus

Salus SSR868 Manual

12 August 2025
Salus

Salus WQ615RX Manual

12 August 2025
Salus

Salus MD28S Manual

12 August 2025
Salus

Salus PL06 Manual

30 Juli 2025
Salus

Salus CB500CO Manual

29 Juli 2025
Salus

Salus UG800 Manual

29 Juli 2025
Salus

Salus TPS10 Manual

29 Juli 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer