Salus RXBC5V Manual

Salus Modtager RXBC5V

Læs gratis den danske manual til Salus RXBC5V (2 sider) i kategorien Modtager. Denne vejledning er vurderet som hjælpsom af 88 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 44.5 anmeldelser. Har du et spørgsmål om Salus RXBC5V, eller vil du spørge andre brugere om produktet?

Side 1/2
www.salus-controls.com
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to
change specification, design and materials of products listed in this brochure without prior notice.
Issue Date: August 2017
V01
For PDF Installation guide please go to
www.salus-manuals.com
Head Oce:
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road, Dodworth,
Barnsley S75 3SP, UK.
T: +44 (0) 1226 323961
E: sales@salus-tech.com
RXBC5V - RF Boiler Control
Press the “SYNC“ button for 3 seconds
until LED starts ashing
The RXBC5V is ready to be paired
with your compatible SALUS device.
6. Push t boiler control into housing.
7. Power up the boiler and check the
correct operation. Note: Once paired please close the boiler control panel
Installation Pairing the RXBC5V
5. Connect the electrical plug.
3 Sec
Introduction
The RXBC5V boiler module 868MHz is a receiver with 5V DC
to control ON/OFF of Boiler or other heat system via the RF
signal transmitted from the thermostat.
Product Compliance
This product complies with the essential requirements
and other relevant provisions of Directives (RED)
2014/53/EU and 2011/65/EU. The full text of the EU
Declaration of Conformity is available at the following
internet address: www.salus-controls.com.
Safety Information
Use in accordance with the regulations. Indoor use
only. Keep your device completely dry. Disconnect your
device before cleaning it with a dry cloth.
868MHz-868.8MHz; <13dBm
Terminal connections
The RXBC5V is compatible with the following
SALUS products
RT310TX
RT510TX iT500BM
RT310iTX
ERT20TX
Compatibility
Terminal Identier Description
1 DC + DC power supply (+)
2 DC - DC power supply (-)
3 COM Common input
4 NO Normal Open
5 NC Normal Closed
Installation
Switch Position
1
1 2 3
2
3
The boiler receiver is o.
AUTO. RX will automatically
receive the RF signal from
your compatible SALUS
device and controls relay
output.
Manual mode - Manual Override (Note this mode
will run your boiler continuously)
1. Ensure boiler is isolated and switched o.
2. Pull down control panel cover.
3. Remove existing mechanical timer and unscrew
from plate.
4. Reverse the procedure to install the RXBC5V.
Note: When removing blanking plate also
remove visible thermostat link plug do not
remove any internal link.
i