Heatit Z-TRM6 DC Manual

Heatit Termostat Z-TRM6 DC

Læs gratis den danske manual til Heatit Z-TRM6 DC (12 sider) i kategorien Termostat. Denne vejledning er vurderet som hjælpsom af 15 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 8 anmeldelser. Har du et spørgsmål om Heatit Z-TRM6 DC, eller vil du spørge andre brugere om produktet?

Side 1/12
1. INTRODUCTION
Heatit Z-TRM6 DC is an electronic thermostat with a
potential free relay, designed for boiler control, heat pumps
and actuators. The thermostat can be controlled through
your Z-Wave® network or via the buttons on the front. The
thermostat has a user friendly interface.
Heatit Z-TRM6 DC has 3 modes; Heat - Cool and Eco.
The thermostat fits in standard European junction boxes and
may be used with most System 55 frames. It has a sturdy metal
frame for secure fastening on the junction box. The thermostat
has one built-in room temperature sensor. Two additional
external temperature sensors may also be connected.
Heatit Z-TRM6 DC allows you to set the power metering value
manually.
The thermostat can be set up with multiple associations and
can be used as a master thermostat. It can control up to 10
thermostats and 10 external relays E.g wall plugs.
The device has a built-in potential free relay of max 3A that is
designed for the usage of up to 3x 24VDC actuators.
2. STATEMENT REGARDING PRODUCTS FROM MULTIPLE
MANUFACTURERS
Please read this before installation
This device may be used with all devices certified with the
Z-Wave Plus® certificate and should be compatible with
such devices produced by any manufacturer. Every primary
controller is dierent depending on the manufacturer, their
target audience and intended use/application. Please review
the functionalities implemented by the primary controller you
intend to use with our Z-Wave Plus certified device to ensure
that it provides the necessary controls to take full advantage of
our product’s capabilities.
3. BEHAVIOR WITHIN THE Z-WAVE NETWORK
This device may be operated within any Z-Wave® network
with Z-Wave-certified devices from other manufacturers. All
non-battery-operated nodes within the network will act as
repeaters regardless of manufacturer to increase the reliability
of the network. On delivery, the device does not belong to any
Z-Wave network. The device needs to be added to an existing
network to communicate with the other devices within it.
Devices may also be removed from a network. The add/
remove processes are initiated by the primary controller of the
Z-Wave network.
PRODUCT
DOCUMENTS
HEATIT
Z-TRM6 DC
Installers manual
Firmware version Document version
FW 1.0 2024-B
Article no. Document date
54 305 61
54 305 63 22.02.2024
Org. doc. date 02.01.2024
White RAL 9003
54 305 61
TABLE OF CONTENTS
1. Introduction
2. Statement regarding
products from multiple
manufacturers
3. Behavior within the
Z-Wave network
4. Quick start
5. Disclaimer installation
6. Connections
7. Installation
8. Add/Remove
9. Factory reset
10. Startup
11. Principles of regulation
12. Local settings menu
13. Display menu structure
14. Temperature shown in
display
15. Standby and main screen
16. KWh value in menu
17. Size of load
18. Choice of sensor
19. Selecting sensor value
20. Calibration
21. Brightness
22. Display on/o
23. Display icons
24. Child lock
25. Open window detection
26. Error codes
27. Safety features
28. QR-Code placement (DSK)
29. Security
30. Node information frame
31. Associations
32. Association groups
33. Configuration parameters
34. Command classes
35. Supported command
classes
36. Controlled command
classes
37. Thermostat dimensions
38. Thermostat controls
39. Chart - Display menu
Product info
Black matt
54 305 63
4. QUICK START
1. Switch o the mains voltage (disable the fuse).
2. Open the junction box.
3. Connect the wires according to the description in
Chapter 6; ”Connections”. Optional: Connect external wired
sensors.
4. After verifying the connections, switch on the mains voltage.
5. Set the primary controller in add mode (security/non-
security).
6. Hold the Center button until “OFF” is shown in the display
(approx. 5 seconds).
7. Press the ”+” button once to reach “CON”, and hold the
center button until the display shows a rotating light pattern.
8. The thermostat will display “INCL” when the thermostat is
successfully added. NB! If adding/removing fails, Err (error)
will appear.
5. INSTALLATION DISCLAIMER
Installation must be done by a qualified electrician in
accordance with national building codes. Before installation,
disconnect the power to the device from the mains. During
installation of the device, power to the device must be
disconnected AT ALL TIMES!
6. CONNECTIONS
Max tightening torque for terminal screws: 2Nm.
If the cable used has multiple strands, using a end sleeve is
advised.
The product allows for wiring of cables with a cross section of
up to 1x2.5mm.
The screw terminals are located at the back of the device, and
are accessable at all times.
Floor sensor NTC type 6.8, 10, 12, 15, 22, 33, 47 or 100kΩ.
Default 10kΩ.
External sensor NTC type 6.8, 10, 12, 15, 22, 33, 47 or 100kΩ.
Default 10kΩ.
Out Output.
In Input.
N Power connection (Neutral) 230VAC.
L Power connection (Live) 230VAC.
7. INSTALLATION
To install the thermostat in the junction box, hold the sides of
the display and gently pull outwards to detach the front piece.
Connect all wires according to the correct diagram. Align the
thermostat with the junction box mounting screws, and mount
it into the junction box using 2 screws. Position the thermostat
front over the part mounted in the junction box, then carefully
press the front until it clicks into place.
24VDC
H a Z M DC
heatit.com
230VAC~50/60Hz
3A 24VDC
N
In
L
Out
Ext.
sensor
Floor
sensor
Art. no. 54 305 61
54 305 62
54 305 63
NTC
NTC
Potential-free input
e.g. for boiler control, heat pumps etc.
Heatit Z-TRM6 DC
heatit.com
230VAC~50/60Hz
3A 24VDC
N
In
L
Out
Ext.
sensor
Floor
sensor
Art. no. 54 305 61
54 305 62
54 305 63
NTC
NTC
Potential-free
input


Produkt Specifikationer

Mærke: Heatit
Kategori: Termostat
Model: Z-TRM6 DC

Har du brug for hjælp?

Hvis du har brug for hjælp til Heatit Z-TRM6 DC stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termostat Heatit Manualer

Heatit

Heatit S-Control2 Manual

19 August 2025
Heatit

Heatit Z-Temp3 Manual

3 Januar 2025
Heatit

Heatit PRO Manual

24 September 2024
Heatit

Heatit MULTIREG6 Manual

24 September 2024
Heatit

Heatit WiFi6 Manual

17 Juli 2024
Heatit

Heatit WiFi Manual

17 Juli 2024
Heatit

Heatit ZM Manual

16 Juli 2024
Heatit

Heatit Z-TRM6 Manual

16 Juli 2024

Termostat Manualer

Nyeste Termostat Manualer

UPM

UPM HTM311A Manual

12 Oktober 2025
Bticino

Bticino NT4451 Manual

8 Oktober 2025
Bticino

Bticino HS4451 Manual

7 Oktober 2025
Bticino

Bticino N4451 Manual

7 Oktober 2025
Bticino

Bticino L4451 Manual

7 Oktober 2025
Bticino

Bticino AM5721 Manual

6 Oktober 2025
Bticino

Bticino L4441FH Manual

6 Oktober 2025
Bticino

Bticino HC4451 Manual

6 Oktober 2025
Emerson

Emerson ST75 Manual

1 Oktober 2025