Læs gratis den danske manual til Lowell RPC-20-SCD-RJ (2 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 16 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 8.5 anmeldelser. Har du et spørgsmål om Lowell RPC-20-SCD-RJ, eller vil du spørge andre brugere om produktet?

Side 1/2
INTERNAL USE ONLY: PN 24325
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2023 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069, USA / tel. 800.325.9660 / tel. 636-257-3400 / www.lowellmfg.com
Spec 1755
Model RPC-20-SCD-RJ | Rev. 1-11-2023 | pg. 1/2
Certied
US Steel
Made In USA
with Global
Components
Ideal for Lowell switches featuring main-
tained closure (order separately):
RPSB-P-RJ Black wall plate w/rocker switch & RJ45
RPSW-P-RJ White wall plate w/rocker switch & RJ45
RPSW-KP-RJ White wall plate w/key switch & RJ45
RPSB-R-RJ Rack panel w/rocker switch & RJ45
RPSB-KR-RJ Rack panel w/key switch & RJ45
REMOTE POWER CONTROLS can be combined with a variety of switches or sequencers (with dry contact
closure or voltage trigger) for an intrinsically safe, low voltage method of controlling AC power to equipment
at remote locations. Controlling power distribution without directly accessing equipment minimizes the po-
tential for unauthorized access, while simplifying activation and deactivation of equipment.
Note: RPCs require an external trigger for activation (order separately).
Model No.
RPC-20-SCD-RJ
Remote Power Control
actives remote equipment external trigger required
FEATURES
CHASSIS: Steel chassis (8.00"L x 3.25"W x
2.75"H) with black finish and mounting holes.
POWER:
Power Rating: 125VAC 60Hz 20A
Outlets: NEMA 5-20R duplex
Attached Cord: 6 ft. cord with NEMA 5-20P plug
SURGE PROTECTION:
Maximum Surge Current: 20,000A
VPR: 400V
Response Time: 1 nanosecond
EMI/RFI Noise Reduction: 20dB@100kHz
Protection Mode: Line to Neutral
Ground Contamination: None
ACTIVATION: Must be connected to an external
control for activation and deactivation (choose one):
Dry Contact Closure: Connect to SPST switch,
power sequencer, or independent control sys-
tem with dry contact closure.
: Contact Coil Rating
- Voltage: 24VDC
- Current: 37.5mA
Voltage Trigger (5-24V AC or DC 5mA):
DSP connection.
ORIGIN: Made in the U.S.A. with global components
THIRD PARTY APPROVAL: ETL Listed to
UL60065 (U.S. and Canada)
INSTALLATION: The RPC is typically installed near
the equipment to be controlled. Low voltage cable
is run from its RJ45 connector (or terminal strip) to
a control switch (or other control method).
Systems can be configured with multiple RPCs
controlled by a single "Maintained Closure"
switch or voltage trigger source.
Systems can also be configured with a single
RPC controlled by multiple "Momentary Clo-
sure" switches and Lowell's MSM2 module
(which converts momentary closure to main-
tained).
COMPATIBLE DEVICES: (order separately)
SPST Switch (RPS Series): Low voltage wall-
mount or rack-mount switch:
Switch with maintained closure con-
nects directly to RPC.
Switch with momentary closure requires
Lowell conversion module MSM2
placed between the switch and RPC.
Power Sequencer (SEQ Series): A low volt-
age sequencer can be used with the RPC
for time-delayed activation and deactivation
of connected equipment. Lowell standalone
sequencers will require a switch for activation,
while Lowell rack-mount sequencers include a
switch. See product spec sheets for information.
A&E SPECIFICATIONS
The device for remotely controlling AC power shall be Lowell model RPC-20-SCD-RJ, which shall feature
a 8.00"L x 3.25"W x 2.75"H steel chassis with black powder epoxy finish, 125VAC 60Hz 20A power rat-
ing, one NEMA 5-20R duplex outlet, 6 ft. cord with NEMA 5-20P plug, and basic surge protection up to
20,000A. The unit shall require an external trigger for activation (not included).
INTERNAL USE ONLY: PN 24325
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2023 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069, USA / tel. 800.325.9660 / tel. 636-257-3400 / www.lowellmfg.com
Spec 1755
Model RPC-20-SCD-RJ | Rev. 1-11-2023 | pg. 2/2
Norm
Test
G
GR
Connect to Lowell
Sequence r or Remote
S chwit ONLY
Sw
Com
V+
Pi ns 1, 2 Sw
Pi ns 3, 4 Com
Pins 5, 6 V+
On
Sw Pi ns 1, 2
Com Pins 43,
V+ Pi ns 5, 6
V Input Trig Pins 87,
*RJ45 Cable –
Use straight-through type cable only
(pin-1 to pin-1, pin-2 to pin-2, etc.)
RJ45 Cable*
or 3 Conductors
GREEN LED (surge protection)
ON = protection active
OFF = protection compromised
RED LED (AC power indicator)
ON = power applied to unit
OFF = no power to unit
TEST SWITCH
TEST = AC power applied to outlets (bypassing external controls)
NORM = external control connections enabled
GREEN LED (outlet power indicator)
ON = power applied to outlets
OFF = no power to outlets
6-ft. cord
NEMA 5-20P plug
requires
NEMA 5-20R outlet
RPC DIAGRAM:
RPC TYPICAL CONTROL METHODS (low voltage, limited current Class 2 wiring):
Switch Schematic
Switch Switch SPST
LED
2.2K 1/2W Resistor Common
+24V Out
No Conn.
+24VDC Out (250mA max.)
Switch
Common
Trigger In (5V-24V AC or DC)
EXAMPLE 1: SPST switch with MAINTAINED closure.
See Lowell RPS Series models listed on pg. 1.
Lowell
SPST Switch
with MAINTAINED
closure
5V-24V, AC or DC, 5mA
ON = voltage applied
OFF = voltage removed
( + )
( – )
+24VDC Out (250mA max.)
Switch
Common
Trigger In (5V-24V AC or DC)
No Conn.
No Conn.
EXAMPLE 3: Voltage Input.
Voltage input from external control system (by others).
Voltage
Input
Follow polarity indicators, if any, on sequencer/controller
(rating: 24V, 37.5mA)
ON = connection applied (closed)
OFF = connection removed (open)
No Conn.
No Conn.
( + )
Com ( )
+24VDC Out (250mA max.)
Switch
Common
Trigger In (5V-24V AC or DC)
EXAMPLE 2: Sequencer or Control System.
Lowell SEQ Series sequencer or control system by others.
Sequencer
or Control
System
ADD Resistor, 4.7 K 1/2W min.
(not included).
EXAMPLE 4: Fire Alarm Panel Interface.
Application Example: RPC controls power to music/paging system.
A signal from Fire Alarm Panel forces music/paging system OFF
so an alarm can be heard.
Alarm
System
Normally Closed (N.C.) line
from Fire Alarm System.
Closed loop from Fire Alarm
Panel holds RPC ON. When loop
is opened by Fire Alarm Panel,
the RPC turns OFF.
Normally Open (N.O.) line
from Fire Alarm System.
Voltage from +24V Out,
through a resistor,* to
Trigger In holds power to
outlet ON. Shorting Trigger In
to Com via Fire Alarm Panel contact
closure forces power to outlet OFF.
+24VDC Out (250mA max.)
Switch
Common
Trigger In (5V-24V AC or DC)
No Conn.
No Conn.
Alarm
System +24VDC Out (250mA max.)
Switch
Common
Trigger In (5V-24V AC or DC)
No Conn.
SERIES OVERVIEW
Model No. Chassis Outlets Input Power Rating Surge Suppression ConnectionsExternal Activation Required
RPC-15 Standalone NEMA 5-15R (2) 6' attached cord 125VAC 60Hz 15A --- Dry contact closure Terminal Strip
RPC-15-S Standalone NEMA 5-15R (2) 6' attached cord 125VAC 60Hz 15A Dry contact closure Terminal StripYes
RPC-15-SCD-RJ Standalone NEMA 5-15R (2) 6' attached cord 125VAC 60Hz 15A Dry contact closure or VT* TS or RJ45Yes
RPC-15-U Standalone IEC C13 (2) 6' detachable cord (2) 100-240VAC 50/60Hz 15A --- Dry contact closure or VT* Terminal Strip
RPC-20-CD Standalone NEMA 5-20R (2) 6' attached cord 125VAC 60Hz 20A --- Dry contact closure or VT* Terminal Strip
RPC-20-SCD Standalone NEMA 5-20R (2) 6' attached cord 125VAC 60Hz 20A Dry contact closure or VT* Terminal StripYes
RPC-20-SCD-RJ Standalone NEMA 5-20R (2) 6' attached cord 125VAC 60Hz 20A Dry contact closure or VT* TS or RJ45Yes
RPC-3N1 Standalone NEMA 5-15R (8) 6' attached cord 125VAC 60Hz 15A --- Dry contact closure Terminal Strip
RPC-4CD Rack-mount NEMA 5-15R (8) 6' attached cord 125VAC 60Hz 15A --- Dry contact closure Terminal Strip
RPC-20-HW Standalone NEMA 20A (2) 6'  exible whip 125VAC 60Hz 20A --- Dry contact closure or VT* Terminal Strip
RPC-20-SHW Standalone NEMA 20A (2) 6'  exible whip 125VAC 60Hz 20A Dry contact closure or VT* Terminal StripYes
RPC-30-SHW Standalone Twistlock 30A (1) 6'  exible whip 125VAC 60Hz 30A Dry contact closure or VT* Terminal StripYes
* VT indicates the RPC can also accept a voltage trigger provided by an independent control system.
T H I S
SPEC


Produkt Specifikationer

Mærke: Lowell
Kategori: Ikke kategoriseret
Model: RPC-20-SCD-RJ
Bredde: 203.2 mm
Dybde: 69.85 mm
Højde: 82.55 mm
Produktfarve: Sort
Ethernet LAN-porte (RJ-45): 1
Indgangsspænding: 125 V
Oprindelsesland: USA
Indgangsfrekvens: 60 Hz
AC udgange, antal: 2 AC stikkontakt(er)
Strøm (maks.): 20 A
Udgangsstrøm (maks.): - W