Læs gratis den danske manual til Schneider MTN647395 (2 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 46 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 23.5 anmeldelser. Har du et spørgsmål om Schneider MTN647395, eller vil du spørge andre brugere om produktet?

Side 1/2
V6473-562-04 11/21
Switch actuator REG-K/x230/16 with manual mode and current detection© Merten2009V6473-562-0411/21
SpaceLogic KNX
Switch actuator REG-K/x230/16 with
manual mode and current detection
Operating instructions
SpaceLogic KNX
Switch actuator REG-K/2x230/16 with
manual mode and current detection
Art. no. MTN647395
SpaceLogic KNX
Switch actuator REG-K/8x230/16 with
manual mode and current detection
Art. no. MTN647895
SpaceLogic KNX
Switch actuator REG-K/12x230/16
with manual mode and current
detection
Art. no. MTN648495
For your safety
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR
ARC FLASH
Safe electrical installation must be carried out only by
skilled professionals. Skilled professionals must prove
profound knowledge in the following areas:
Connecting to installation networks
Connecting several electrical devices
Laying electric cables
Connecting and establishing KNX networks
Safety standards, local wiring rules and regulations
Failure to follow these instructions will result in
death or serious injury.
RISK OF FATAL INJURY FROM ELECTRIC SHOCK
The output may carry electrical current even when the
load is switched off.
When working on the device: Always disconnect the
device from the supply by means of the fuse in the in-
coming circuit.
Even if the manual switch is in the „OFF“ position, a
KNX telegram can switch the connections to being
live at any time. Before working on the device, always
diconnect the fuse in the incoming circuit from the
supply.
Failure to follow these instructions will result in
death or serious injury.
en
L 2L 1
5 6 7 81 2 3 4
LL 1 2 LL 3 4 LL 5 6 LL 7 8
567891011121234
LL 5 6 LL 7 8 LL 9 10 LL 11 12LL 1 2 LL 3 4
L 2L 1
5 6 7 81 2 3 4
LL 1 2 LL 3 4 LL 5 6 LL 7 8
567891011121234
LL 5 6 LL 7 8 LL 9 10 LL 11 12LL 1 2 LL 3 4
The switch actuator REG-K/x230/16 with manual mode
and current detection (referred to below as the actuator)
can switch
two loads (MTN647395) or
eight loads (MTN647895) or
twelve loads (MTN648495)
via separate, floating make contacts.
You can also manually switch the connected loads with
manual switches on the actuator without bus voltage.
The actuator has a bus coupler. It is installed on a DIN rail
TH 35 according to EN 60715, with the bus connection
made via a bus connecting terminal. It is supplied with
power from the bus voltage. A data rail is not required.
The actuator also has integrated current detection wich
measures the load current of each channel.
ABus connection terminal, max. 4 core pairs
BProgramming LED (red)
CProgramming button
DCable cover
EOperating LED „RUN“ (green)
FManual switch
GScrew terminals
The device may be damaged!
Always operate the product in compliance with the
specified technical data.
Do not use the current detection function for applica-
tions relevant to safety.
Connect only pure ohmic loads to a channel with di-
rect current (DC).
Only install devices with at least basic insulation next
to the device.
Failure to follow these instruction can result in
equipment damage.
Getting to know the actuator
Connections, displays and operating
elements
L L 2L L 1
KNX
1 2
D
C
AB
E
F
G
½CAUTION
Strong magnetic fields can influence the current
measurement. Install devices with a strong mag-
netic field (e.g. wound transformers such as bell
transformers) at least 2 cm away from the actua-
tor.
1Set the actuator onto the DIN rail.
2Connect KNX.
¼WARNING
Risk of death from electric shock. The device
can become damaged.
Safety clearance must be guaranteed in accord-
ance with IEC 60664--1. There must be at least 4
mm between the individual cores of the 230 V
supply cable and the KNX line A.
Mounting the actuator
RISK OF FATAL INJURY FROM ELECTRIC SHOCK
Voltage may be present at the outputs when the mains
voltage is connected to the system.
If subjected to strong vibrations during transportation,
the switch contacts might change to the enabled state.
After connecting the bus voltage, set the relays of the
channels to the position desired simply by switching
„On/Off“ or by changing the manual switch to „OFF“.
Failure to follow these instructions will result in
death or serious injury.
The device may be damaged!
Protect the switch contacts with a series-connected
16 A circuit breaker.
Failure to follow these instruction can result in
equipment damage.
1
2
1 2
3 4
5 mm
230 V
4 mm
A
V6473-562-04 11/21
3Connect the bus voltage.
4Wait at least 30 seconds.
5Switch the relays of the channels on and off manu-
ally once with the manual switches.
6Connect the load.
7Connect the mains voltage.
Now you can check the functionality of the actuator and
the connected loads without having to load the applica-
tion from the ETS (See the section "Operating the actua-
tor").
1Press the programming button.
The programming-LED lights up.
2Load the physical address and application into the
device from the ETS.
The programming LED goes out.
The operation LED lights up: The application was loaded
successfully, the device is ready for operation.
Normally, you control connected devices using push-
buttons or by remote control. However, you can manually
switch each of the actuator‘s channels on and off directly
at the manual switches.
The green LED „RUN“ is not lit.
The bus voltage has failed.
Check the bus voltage, only manual operation is
possible.
The application was not loaded properly.
Load it again.
Putting the actuator into operation
Operating the actuator
What should I do if there is a problem?
KNX
16 A 16 A 16 A
L1 NL3L2
1
x
..........
Technical data
Power supply from
bus:
DC 24 V / approx. 16 mA
For alternating current (AC) per channel
Nominal voltage: AC 100–240 V ±10%
Operation voltage: min. AC 90 V – max. AC 265 V
Mains frequency: 50–60 Hz ±10%
Nominal current: 16 A, cosφ=0.6
Connected load
Incandescent
lamps:
1600 W at AC 100 V
3600 W at AC 230 V
3840 W at AC 240 V
Halogen lamps: 1086 W at AC 100 V
2500 W at AC 230 V
2608 W at AC 240 V
Fluorescent lamps: 1086 VA at AC 100 V
2500 VA at AC 230 V
2608 VA at AC 240 V
parallel compensated
Capacitive load: 16 A, 200 µF at AC 100 V
16 A, 200 µF at AC 230 V
16 A, 200 µF at AC 240 V
Motor load: 434 W at AC 100 V
1000 W at AC 230 V
1043 W at AC 240 V
Switching frequency: max. 10 per minute at nominal
load
Fuse: one 16 A circuit breaker connect-
ed upstream per channel
Current detection (load current)
Detection range
(sine effective val-
ue): 0.1–16 A
Sensing accuracy: ±8% from the existing current val-
ue (sine) and ±100 mA
Frequency: 50/60 Hz
Display: 100 mA
Sensing speed (τ): 200 ms
For direct current (DC) per channel
Nominal voltage: DC 12–24 V ±10%, 0.1–16 A
Nominal current: 16 A
CAUTION: Connect only pure ohmic loads to a channel
with direct current (DC).
Switching frequency: max. 10 per minute at nominal
load
Fuse: one circuit breaker capable of op-
erating with direct current con-
nected upstream per channel
Current detection (load current)
Detection range: 0.1–16 A
Sensing accuracy: ±8% from the existing current val-
ue and ±100 mA
Display: 100 mA
Sensing speed (τ): 200 ms
Ambient temperature:
Operation: -5 °C to +45 °C
Max. humidity: 93 %, no moisture condensation
Environment: can be used at up to
2000 m above sea level (MSL)
Operating elements: 1 programming button
2 manual switches
Display elements: 1 red LED: programming check
1 green LED: ready for operation
„RUN“
Connections
Bus: via two 1 mm pins for bus con-
necting terminal
Load: 1 x 2-gang screw terminal for
max. 2.5 mm2 with one conduc-
tor or max. 1.5 mm2 with two con-
ductors per channel
Schneider Electric Industries SAS
35 rue Joseph Monier
Rueil Malmaison 92500
France
If you have technical questions, please contact the Cus-
tomer Care Centre in your country.
se.com/contact
EC directives: Low voltage directive 2006/95/
EC
EMC-directive 2004/108/EC
Device width
MTN647395: 2.5 modules = approx. 45 mm
MTN647895: 8 modules = approx. 140 mm
MTN648495: 12 modules = approx. 210 mm
Schneider Electric -Contact
Schneider Electric Limited
Telford, TF3 3 BL, UK
UK Representative
Stafford Park 5


Produkt Specifikationer

Mærke: Schneider
Kategori: Ikke kategoriseret
Model: MTN647395

Har du brug for hjælp?

Hvis du har brug for hjælp til Schneider MTN647395 stil et spørgsmål nedenfor, og andre brugere vil svare dig