Læs gratis den danske manual til Silverline 589681 (5 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 20 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 10.5 anmeldelser. Har du et spørgsmål om Silverline 589681, eller vil du spørge andre brugere om produktet?

Side 1/5
www.silverlinetools.com
Digital Multimeter
AC & DC
589681
Range Resolution Accuracy
200V 100mV ± (1.2% of reading +
10 digits)
500V 1V
AC Voltage / Tension c.a. / Wechselspannung /
Tensión c.a. / Tensione CA / Wisselspanning
Overload protection: 500V DC or 500V rms for all ranges
Range Test Range Test Current Test Voltage
NPN & PNP 0-1000 1b - 10µA Vce = 3V
Transistor hFE test (0-1000)/ Test de valeur hFE de transistor (0-1000)/
Transistor-(hFE)-Test (0–1000)/ Prueba de transistores hFE (0-1000)/
Transistor hFE test (0000-1000)/ Transistor HFE test (0-1000)
Range Resolution Accuracy
200mV 100 Vµ± (0.5% of read-
ing + 3 digits)
2000mV 1mV
± (1.0% of read-
ing + 5 digits)
20V 10mV
200V 100mV
500V 1V ± (1.2% of read-
ing + 5 digits)
DC Voltage / Tension c.c. / Gleichspannung /
Tensión c.c. / Tensione CC / Gelijkspanning
Overload protection: 220V rms AC for 200mV
range and 500V DC or 500V rms for all ranges
Range Resolution Accuracy
200µA 100nA
± (1.8% of reading
+ 2 digits)
2000µA 1µA
20mA 10µA
200mA 100µA ± (2.0% of reading
+ 2 digits)
5A 10mA ± (2.0% of reading
+ 10 digits)
Range Resolution Accuracy
200 Ω 0.1m Ω ± (1.0% of reading
+ 10 digits)
2000 Ω 1 Ω
± (1.0% of reading
+ 2 digits)
20 Ω 10 Ω
200K Ω 100 Ω
2000K Ω 1K Ω
Resistance / Résistance / Widerstand /
Resistencia / Resistenza / Weerstand
Overload protection: 15 seconds maximum 220V rms
3
4
7
5
6
1 8
Range Description
Built-in buzzer sounds if resistance is less than 30 Ω± 20
Audible Continuity/ Continui audible/ Akustische
Durchgangsprüfung/ Continuidad audible/ Continuiudibile/
Hoorbare continuïteit
Overload protection: 15 seconds maximum 220V rms 2
Digital Multimeter
Multimètre numérique
Digitalmultimeter
Multímetro digital
Multimetro digitale
Digitale multimeter
Range Resolution Accuracy Overload
Protection +/- 0.5%
of reading
+/- 5
digits
Test
Range Test Current Test Voltage Built-in buzzer
sounds if
resistance is
less than 30 ±
20 Ω
Overload protection:
0.5A/500V and
5A/500V fuse
220V rms AC for 200mV
range and 500V DC or
500V rms for all ranges
Plage Résolution Précision protection
surcharge +/-0,5 %
de la valeur
+/- 5
chiffres
Plage
d’essai Intensité
d’essai Tension
d’essai Le signal
sonore retentira
si la résistance
est inférieure à
30 ± 20 Ω
Protection
surcharge : fusible
0,5 A / 500 V et 5
A / 500 V
220 V c.a. pour plage
de 200 mV et 500
Vc.c. ou 500 V rms
pour autres plages
Bereich Auflösung Genauigkeit Überlast-
schutz +/- 0,5%
v. M. +/- 5
Digits
Prüfbe-
reich Prüfstrom Prüfspan-
nung Eingebauter
Signalton
ernt, wenn
der Widerstand
unter 30 ± 20
Ω liegt
Überlastschutz:
0,5 A/500 V und
5 A/500-V-
Sicherung
220V Effektivwert
(RMS) Wechsel-
spannung (AC) für
200-mV-Bereich und
500 V Gleichspan-
nung (DC) oder 500 V
Effektivwert (RMS) für
alle Messbereiche
Escala Resolución Precisión Protección
contra
sobrecar-
gas
+/-0,5%
de lectura
+/- 5 dígi-
tos
Escala de
prueba Intensidad
de prueba Tensión de
prueba Se oye la señal
sonora cuando
la resistancia
es inferior a 30
± 20 Ω
Protección contra
sobrecargas :
fusible 0,5 A / 500
V y 5 A / 500 V
220 V c.a. para escala
de 200 mV y 500 V
c.c. ó 500 V rms para
otras escalas
Inter-
vallo Risoluzi-
one Precisione protezione
sovrac-
carico
+/- 0,5%
lettura
+/-5 cifre
Prova
gamma Prova
Corrente Prova
Tensione Segnale acus-
tico incorporato
se la resistenza
è minore di 30
± 20 Ω
Protezione
da sovracca-
rico: 0.5A/500V e
5A/500V fusibile
220 V ca per la
gamma di 200 mV e
500 V cc o 500 V rms
per tutte le gamme
Bereik Resolutie Nauw
keurigheid Overb-
elasting
beveilig-
ing
+/- 0,5%
van lezing
+/- 5
cijfers
Test
bereik Test gelijkst-
room Test
spanning Ingebouwd
alarm luid
wanneer de
weerstand
onder de 30/20
Ω reikt
Overbelastings-
beveiliging: 0,5
A/500 V en 5
A/500 V zekering
200Vms AC voor
200mV bereik en 500
V DC of 500V RMS
voor andere bereiken
DC Current / Intensic.c. / Gleichstrom /
Corriente c.c. / Corrente CC / Gelijkstroom
Overload protection: 0.5A/500V and 5A/500V fuse
www.silverlinetools.com
As part of our ongoing product development, specifications of Silverline
products may alter without notice
ACCURACY
Accuracy is specified for a period of one year after calibration and within
temperature range 1- 2C with 80% max relative humidity
Before Use
Unpacking
Ensure that all parts of your multimeter are present and in good condition.
If any part is missing, or damaged, have such parts replaced before
attempting to use this tool
Assembly
1. Remove the two screws from the back of the multimeter.
2. Take the back off and insert a 9V battery.
3. Connect the battery - align the battery with the connector so that the
terminals on the battery and the connector snap-fit together securely.
4. Insert the battery into the compartment, replace the panel carefully
and re-tighten the screws.
Operating
NOTE:
• Every time this multimeter is used, inspect the test leads, connectors
and probes for damage. If the leads are damaged have them replaced
by an authorised service centre
• If in doubt as to range required, select the highest range and then
reduce it as necessary until satisfactory resolution is obtained
• If the figures ‘1’ or ‘-1’ are displayed, this indicates the reading is out of
the set range
Voltage measurement
•Connect the red Positive Lead (1) to the VΩmA Jack (6)
•Connect the black Negative Lead (2) to the COM (Common) Jack (7)
• Rotate the Function Selector (4) to select the required voltage range in
the correct DC or AC range
•Connect the test leads to the circuit being measured
• Turn on the power to the circuit being measured. The value of the
voltage passing through the circuit should be displayed on the LCD
Display (3), along with the polarity (if reversed only)
DC Current measurement
•For measurements up to 200mA: Connect the red Positive Lead (1) to
the VΩmA Jack (6)
• For measurements above 200mA, up to max 5A: Connect the red
Positive Lead (1) to the 5A Jack (5). Please note the 5A circuit is unfused
•Connect the black Negative Lead (2) to the COM (Common) Jack (7)
•Rotate the Function Selector (4) to select the required amperage range
• Make the circuit being measured open, connect the test leads across the
opening to create a bridge over the gap
• Turn on the power to the circuit being measured, the value of the current
passing through the circuit should be displayed on the LCD Display (3)
Resistance measurement
NOTE: If the resistance to be measured is part of a circuit, turn off and
disconnect the power and discharge all capacitors before measurement.
•Connect the red Positive Lead (1) to the VΩmA Jack (6)
•Connect the black Negative Lead (2) to the COM (Common) Jack (7)
•Rotate the Function Selector (4) to select the required ohm range
•Connect the test leads to the circuit being measured
•The resistance value should now be displayed on the LCD Display (3)
NOTE: While measuring resistance about 1MΩ and above, the meter may
take a few seconds to stabilise. This is normal for high resistance readings.
Diode testing
•Connect the red Positive Lead (1) to the VΩmA Jack (6)
•Connect the black Negative Lead (2) to the COM (Common) Jack (7)
•Rotate the Function Selector (4) to the setting
•Connect the red test lead to the anode of the diode to be tested and the
black test lead to the cathode of the diode
•The approx. forward voltage drop of the diode should be displayed on
the LCD Display (3)
NOTE: If the connection is reversed, only figure ‘1’ will be displayed
Continuity testing
•Connect the red Positive Lead (1) to the VΩmA Jack (6)
•Connect the black Negative Lead (2) to the COM (Common) Jack (7)
•Rotate the Function Selector (4) to the setting
•Connect the test leads to the circuit being measured
• If continuity exists (i.e. resistance is less than approx. 50Ω), the built-in
buzzer will sound
Transistor testing
•Rotate the Function Selector (4) to the ‘hFE’ position
•Determine whether transistor is NPN or PNP
•Locate the emitter, base and collector leads
•Insert the leads into the appropriate holes in the ‘hFE’ Socket (8): The left
side of the socket is configured for PNP, the right side for NPN
•The approximate hFE value will be displayed on the LCD display at the
testing condition of base current 10μA and Vce 3V
Test signal use
•Rotate the Function Selector (4) to the setting
•A test signal (50Hz) appears between VΩmA and COM jack, the output
voltage is approx to 5V p-p with 50KΩ impedence
Storage and Maintenance
WARNING: Ensure that the test leads are disconnected prior to storing or
carrying out any maintenance on this tool
• Store the unit in a clean, dry environment within the temperature range
-10°C to +50°C
• If the test leads are damaged in any way, replace them with new leads
of the same type and specification
•If the unit malfunctions, have it serviced by a suitably qualified
technician
•If you need to replace the battery, use method described in ‘Assembly
EC Declaration of Conformity
The undersigned: Mr Darrell Morris
as authorised by: Silverline Tools
Declares that the
Name/ model: Digital Multimeter
Type/ serial no: 589681
Conforms to the following Directives:
• Low Voltage Directive 2006/95/EC
• EMC Directive 2004/108/EC
• EN61010-1:2001
• EN61010-031:2002+A1:2008
• EN61326-1:2006
• EN61326-2-2:2006
The technical documentation is kept by: Silverline Tools
Notified body: Shenzhen Easy Test Electronic Products Co Ltd
Place of declaration: Futian, Shenzhen, China
Date: 01/11/11
Signed by:
Director
Name and address of Manufacturer or Authorised representative:
Silverline Tools, Boundary Way, Lufton Trading Estate, Yeovil, Somerset,
BA22 8HZ United Kingdom
Dans le cadre duveloppement de nos produits, les caractéristiques
techniques des produits Silverline peuvent être modifiées sans préavis.
Pcision
La précision est indiqe pour une période d’un an à la suite de la calibration
et dans une plage de températures allant de 18 °C à 28 °C, sous 80 %
d’humidirelative.
Avant utilisation
Déballage
Veillez à retirer tout le matériau d’emballage et familiarisez-vous avec toutes
les caractéristiques du produit. Si une pce est endommagée ou manquante,
faites-la parer ou remplacer avant d’utiliser l’appareil.
Insertion de la pile
1. Dévissez les deux vis de l’arrière de l’appareil
2. Enlevez le couvercle avec soin
3. Raccordez la pile neuve sur les cosses prévues à cet effet
4. Insérez la pile dans son compartiment, remettez le couvercle en place
et revissez les vis
Mode d’emploi
NOTA:
A chaque mise en service, vérifiez lexistence déventuels dommages sur les
fils de contrôle, connecteurs et sondes. Si les fils sont endommas, faites-
les remplacer immédiatement par un centre deparation agé
En cas de doute quant à la plage requise, sélectionnez la plage la plus élevée
puis réduisez-la jusqu’à obtenir unesolution satisfaisante
Si les chiffres ‘1ou ‘’-1 saffichent, la mesure est en-dehors de la plage
Mesure de tension
•Branchez le fil positif rouge (1) à la borne VΩmA (6)
•Branchez le fil négatif noir (2) à la borne COM (Commune) (7)
•Sélectionnez la plage de tension appropriée dans la plage c.c. ou c.a. à
l’aide du sélecteur de fonction (4)
•Branchez les fils de contrôle sur le circuit à mesurer
•Mettez le circuit sous tension. La valeur de la tension du circuit, ainsi
que la polarité (si en polarité inversée), s’affichent sur l’écran à cristaux
liquides (3)
Mesure d’intensic.c.
Pour des mesures inférieures à 200 mA : branchez le fil positif rouge (1)
dans la borne mA (6)
Pour des mesures supérieures à 200 mA et jusqu’à 5 A maximum :
branchez lel rouge dans la borne 5 A (5). Veuillez noter que le circuit 5 A ne
contient pas de fusible
Branchez le fil négatif noir (2) à la borne COM (Commune) (7)
lectionnez la plage d’intensité à l’aide du sélecteur de fonction (4).
Ouvrez le circuit pour pouvoir brancher les fils de contrôle et placez le
multitre à l’endroit de l’ouverture
Mettez le circuit sous tension. La valeur de l’intensité du circuit, ainsi que la
polarité (si en polarité inversée), s’affichent sur l’écran à cristaux liquides (3)
Mesure d’une résistance
NOTA : Pour mesurer une résistance faisant partie d’un circuit,branchez et
coupez lalimentation et déchargez tous les condensateurs avant de proder
à la mesure.
•Branchez le fil positif rouge (1) à la borne VΩmA (6)
•Branchez le fil négatif noir (2) à la borne COM (Commune) (7)
•Sélectionnez la plage de résistances (Ω) requise à l’aide du sélecteur
de fonction (4)
•Branchez les fils de contrôle sur le circuit à mesurer
•La valeur de résistance s’affiche sur l’écran à cristaux liquides (3)
NOTA : A la mesure de résistances d’environ 1 MΩ et plus, il est possible
que l’appareil mette quelques secondes à se stabiliser. Cela est normal
pour les mesures de résistances élevées
Test d’une diode
Branchez le fil positif rouge (1) à la borne mA (6)
Branchez le fil négatif noir (2) à la borne COM (Commune) (7)
lectionnez la fonction à laide du sélecteur de fonction (4)
Raccordez le fil de contrôle rouge à l’anode de la diode à tester et le fil de
contrôle noir à la cathode de la diode
La chute de tension directe approximative de la diode s’affichera sur l’écran
à cristaux liquides (3)
NOTA : Si le branchement est inversé, l’écran affichera uniquement un 1”.
Test de continuité
•Branchez le fil positif rouge (1) à la borne VΩmA (6)
•Branchez le fil négatif noir (2) à la borne COM (Commune) (7)
•Tournez le lecteur de fonction (4) sur
•Branchez les fils de contrôle sur le circuit à mesurer
•La présence de continuité (signifiant une résistance inférieure à env. 50
Ω) est signalée par un signal sonore
Test de transistor
•Tournez le lecteur de fonction (4) sur la position « hFE »
•terminez si le transistor est du type NPN ou PNP
•Identifiez les fils de l’émetteur, de la base et du collecteur
•Insérez les fils dans les trous appropriés de la prise hFE (8) : le côté
gauche de la prise est configuré pour un transistor PNP et le côté droit
pour NPN
•La valeur hFE approximative s’affichera sur l’écran à cristaux liquides à
la condition d’essai d’une intensité de base de 10 µA et Vce de 3 V
Utilisation du signal d’essai
Tournez le sélecteur de fonction (4) sur la position
Un signal d’essai (50 Hz) est généré entre les bornes VΩmA et COM, dont
la tension de sortie est d’environ 5 V crête à crête, pour une imdance de
50
Rangement et entretien
AVERTISSEMENT: Assurez-vous que les fils de contrôle soient débranchés
avant de ranger l’appareil ou d’effectuer une opération d’entretien.
•Rangez l’appareil dans un endroit sec et propre dans une plage de
température de -10 à +50 ºC
•Si les fils de contrôle présentent une quelconque anomalie, remplacez-
les avec des fils du même type et de caractéristiques techniques
identiques
•En cas de dysfonctionnement, faites réparer l’appareil par un technicien
qualifié
•Pour remplacer la pile, suivez les consignes indiquées dans la section «
Insertion de la pile »
Déclaration de conformité CE
Le soussigné : Mr Darrell Morris
Autorisé par : Silverline Tools
Déclare que le produit :
Nom/modèle : Multimètre numérique
Nº de série/Type : 589681
Est conforme aux directives suivantes :
•Directive sur les basses tensions 2006/95/CE
• EMC Directive 2004/108/CE
• EN61010-1:2001
• EN61010-031:2002+A1:2008
• EN61326-1:2006
• EN61326-2-2:2006
La documentation technique est conservée par : Silverline Tools
Organisme notifié : Shenzhen Easy Test Electronic Products Co Ltd
Lieu de la déclaration : Futian, Shenzhen, Chine
Date : 01/11/11
Signature :
Directeur
Nom et adresse du fabricant ou de son représentant agréé :
Silverline Tools, Boundary Way, Lufton Trading Estate, Yeovil, Somerset,
BA22 8HZ Royaume-Uni
1) Fil positif
2) Fil négatif
3) Écran à cristaux liquides
4) Sélecteur de fonction
5) Borne 5 A CC
6) Borne VΩmA
7) Borne COM
8) Prise hFE
1) Positive Lead
2) Negative Lead
3) LCD Display
4) Function Selector
5) 5A DC Jack
6) VΩmA Jack
7) Common Jack
8) hFE Socket
SPECIFICATION
Battery type: 9V
DC voltage: 200mV - 1000V
AC voltage: 200 - 750V
DC current: 200μA - 5A
Resistance: 200 ohm - 2000k ohm
CARACTERISTIQUES
TECHNIQUES
Pile: 9 V
Tension c.c: 200mV - 1000 V
Tension c.a: 200 - 750 V
Intensité c.c:200μA - 5 A
Résistance: 200 ohm -
2000k ohm


Produkt Specifikationer

Mærke: Silverline
Kategori: Ikke kategoriseret
Model: 589681

Har du brug for hjælp?

Hvis du har brug for hjælp til Silverline 589681 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Silverline Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer