Læs gratis den danske manual til Hager EE840 (4 sider) i kategorien Bevægelsesdetektor. Denne vejledning er vurderet som hjælpsom af 23 personer og har en gennemsnitlig bedømmelse på 3.9 stjerner ud af 12 anmeldelser. Har du et spørgsmål om Hager EE840, eller vil du spørge andre brugere om produktet?

Side 1/4
+ 90°/- 30°
Description
Detection zone
Installation
Setting
15 min
5 s
5 min
auto -+
lux
test
Accessories for corner  xing
Plate for wall  xing
Detection head
Connection by PIN system
(4 plug-in pins)
Vertical adjustment
The optimal height of installation is 2.5 m.
The detection  eld must remain free.
2,5 m
α = 360°
Ø 12 m
3 m
6 m
Fixed time
(length of time
of lighting)
Luminosity Sensitivity
(modi cation
of the range)
Setting potentiometers
Ligthing loads
Incandescent, halogen 23
Halogen ELV (12 or 24 V)
via ferromagnetic or elect
transformer
Compactfluo
Parallel compensated fluo
Electronic ballast
Caution!
This device is to be installed only by a professional
electrician tter according to local applicable
installation standards.
Do not plug in or unplug this product when it is live.
DETECTOR 360°
EE840 White
EE841 Charcoal
ACCESSORY FOR
CORNER FIXING
EE855 White
EE856 Charcoal
6E7574.C1
6E7574.C
EE84.
izMotion detector comfort 360°
Testing and validating
the detection zone
Put the potentiometer on Test mode. The Test 2
mode is available for 3 min.
Every movement detected switches on the light for
1s. After 3 min without detection of movement, the
product returns to normal operation.
Limiting the detection zone
You can limit the detection zone by tilting the
head.
“Normal” operation (on/off)
The lighting is activated whenever the level of
luminosity dened by the potentiometer is 2
judged to be insufcient and a movement is
detected.
After detection, the light stays on for the length
of time predened by the potentiometer .1
The xed timing is reset after each detection.
Please note: when the potentiometer is on “auto
test”, the settings are predened.
Control by timer
An impulse is generated every 10 s whenever the
level of luminosity is judged to be insufcient and
a movement is detected when the potentiometer
1 is on .V
This pulse mode is not suitable for connections to
power devices (except at low power loads).
Operating precautions
In order to obtain optimal detection conditions, it is recommended that the following advice:
- the detection is sensitive to solar radiation and bad weather. Detection performance is optimal up to
35 °C and above 40 °C.
- It is preferable to maintain à distance of 1 m. between a light source and the detector.
When mounting on a box, make sure that you do not distort the wall plate through excessive tightening
of the screws.
Montage
Surface-mounting or ceiling-mounted :
- x the wall plate using the screws provided
- connect the wall plate terminal block (see cabling plans in annex)
- fully insert the detector on the wall plate
- tighten the screws to ensure the product is sealed.
For corner xing, the wall plate is to be xed between the accessory and the detector.
Cable entry (breakable partitions) are possible:
- by the back (box mounting) or by the bottom.
Action Settings Potentiometer
Use Auto settings
(factory) to switch the
light automatically for
a given time.
Auto Settings
Put the Lux potentiometer on
“auto test”.
The settings are predened:
Lux = (operating at night only)o
time = 3 min,
sensitivity = max.
Automatically switch
on the light for a
defined time.
Installer settings
Control a timer, a bell
etc. Impuls V
Auto settings are usable with
time = 1s. (cannot be changed)
Test and validate the
detection zone. Test mode
Move the potentiometer 2 to
“auto test”.
Adjust the sensitivity. Allows setting the range
to avoid disturbance.
Product presentation
and operating principles
This detector allows automatic control of a
light source for a dened length of time when a
movement is detected in the surveillance zone.
Settings and Test
The detectors have 2 modes of operation:
Fixed time and Control by timer.
Power supply
The detector switches the light on for 40 s.
After 40 s, it activates the Normal mode.
10A AC1 230 V~
30 1500 W
tronic 1500 VA
10 x 20 W
orescent tubes 400 WÓ/ C=45 µf
580 W
60 mm
N
L
LN S'
S'
Ateha raceways
ref. ATA 12200
or ATA 63000
Wiring and connections (provide installation with xed wiring)
6E7574.C2


Produkt Specifikationer

Mærke: Hager
Kategori: Bevægelsesdetektor
Model: EE840

Har du brug for hjælp?

Hvis du har brug for hjælp til Hager EE840 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Bevægelsesdetektor Hager Manualer

Hager

Hager TXD503 Manual

30 December 2025
Hager

Hager EER503 Manual

9 December 2024
Hager

Hager EED513 Manual

9 December 2024
Hager

Hager EER513 Manual

9 December 2024
Hager

Hager EED515 Manual

9 December 2024
Hager

Hager EED518 Manual

9 December 2024
Hager

Hager EER515 Manual

9 December 2024
Hager

Hager TXD501 Manual

9 December 2024
Hager

Hager TXC518 Manual

9 December 2024
Hager

Hager TXC515 Manual

9 December 2024

Bevægelsesdetektor Manualer

Nyeste Bevægelsesdetektor Manualer