Lowell ACS-2010-RPC-HW Manual

Lowell Ikke kategoriseret ACS-2010-RPC-HW

Læs gratis den danske manual til Lowell ACS-2010-RPC-HW (3 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 20 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 10.5 anmeldelser. Har du et spørgsmål om Lowell ACS-2010-RPC-HW, eller vil du spørge andre brugere om produktet?

Side 1/3
INTERNAL USE ONLY: PN 24218
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2023 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069, USA / tel. 800.325.9660 / tel. 636-257-3400 / www.lowellmfg.com
Spec 1109
Model ACS-2010-RPC-HW | Rev. 12.20.23 | pg. 1/3
POWER RATING: 120VAC 60Hz 20A
CHASSIS: 30” x 2 x 2 steel chassis with black powder epoxy finish
TERMINATION: Hardwired non-metallic flexible conduit (whip) with pigtail leads. The six ft.
conduit can be trimmed in the field if needed.
RECEPTACLES: Total of ten NEMA 5-20R receptacles (five duplex). One duplex is un-
switched (always on when the unit is supplied with power). Four duplexes are switched
(controlled by a remote switch or sequencer through the RPC terminal).
UNIVERSAL MOUNTING BRACKETS: The universal brackets allow for power strip instal-
lation in a variety of applications with receptacles facing front, center or rear. Brackets are
engineered with multiple mounting points and include two types of hardware to facilitate
easy installation in a rack with adjustable or fixed rails, to a wall, or under a desk/counter.
The brackets can be mounted so they are exposed for easy access or concealed beneath
the power strip for an aesthetically cleaner installation.
CERTIFICATION: ETL Listed in U.S./Canada
ORIGIN: Assembled in the U.S.A. with global components.
INSTALLATION
Use the universal mounting brackets to install the power strip near the equipment. Use
low-voltage cable to connect the RPC terminal to a remote switch or sequencer.
Hardwired power strip with ten 20A receptacles (ve duplex) and remote power control func-
tion (RPC) can be combined with a variety of remote switches or sequencers to provide a
low-voltage method of turning specic equipment on and off from a remote location. The
ability to safely control AC power distribution without directly accessing equipment adds
convenience, while minimizing the potential for unauthorized system modications.
ACS Series Model No.
ACS-2010-RPC-HW
AC Power Strip w/Remote Power Control
FEATURES
Certied
US Steel
S
t
r
o
n
g
e
r
.
G
r
e
e
n
e
r
.
B
e
t
t
e
r
.
Assembled
In USA
with Global
Components
A&E SPECIFICATIONS
The ETL Listed power strip with remote power control shall be Lowell model ACS-2010-
RPC-HW, which shall have a power rating of 120VAC 60Hz 20A. The chassis shall be steel
with black powder epoxy finish, measuring 30 x 2 x 2. It shall feature one unswitched
and four switched NEMA 5-20R duplex receptacles. The four switched duplexes shall be
controlled by an external power switch or sequencer (ordered separately) that is connected
to the power strip’s remote power control terminal. The power strip shall be made in the
U.S.A. with global components. It shall terminate with a six ft. non-metallic flexible conduit
with pigtail leads, and include universal mounting brackets with hardware to mount to a
rack, wall or desk.
Note: An external
power switch or se-
quencer is required
(order separately,
pg. 2).
Six-ft.
non-metallic
exible conduit ro-
tates in any direction.
RPC terminal
connects to a
remote switch
or sequencer.
Four
duplexes are
controlled by a
remote switch
or sequencer
connected to
the RPC
terminal.
One duplex
is unswitched
(always on).
Mounting brackets
INTERNAL USE ONLY: PN 24218
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2023 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069, USA / tel. 800.325.9660 / tel. 636-257-3400 / www.lowellmfg.com
Spec 1109
Model ACS-2010-RPC-HW | Rev. 12.20.23 | pg. 2/3
On: Green LED indicates AC power is applied to receptacles.
Power: Red LED indicates AC power is available.
Test: Test applies power to receptacles independent of remote switch or sequencer.
SW, Com: Connection between Switch and Common terminals activates internal relay and applies power to receptacles.
V+ Out: +24VDC output. Use only with RPS Series switches
Ex. Lowell RPS Series
REMOTE POWER CONTROL: Use low-voltage cable to connect the RPC terminal to an external switch or sequencer.
Remote
Switch
Sequencer
Connection to Remote Switch
(wall or rackmount):
Connection to Sequencer or Control System
with dry contact closure:
RPC Terminal:
Ex. Lowell SEQ Series
(w/classic connections)
Model No.
Description
RPSW-P
SPST switch w/maintained closure, one-gang white wall plate, rocker switch
RPSW-KP
SPST switch w/maintained closure, one-gang white wall plate, key switch
RPSB-R
SPST switch w/maintained closure, 1U rackmount panel, rocker switch
PRSB-KR
SPST switch w/maintained closure, 1U rackmount panel, key switch
SEQ-4
Four-step sequencer
SEQ-8
Eight-step sequencer
SEQR-4
Four-step rackmount sequencer w/rocker switch, 1U
SEQR-4K
Four-step rackmount sequencer w/key switch, 1U
SEQR-8
Eight-step rackmount sequencer w/rocker switch, 1U
SEQR-8K
Eight-step rackmount sequencer w/key switch, 1U
COMPATIBLE Switches & Sequencers: Order separately. See individual product spec sheets for more information.
3) REATTACH CONNECTOR:
Twist/push the connector to attach it to
the shortened conduit.
1) REMOVE EXCESS LENGTH:
Snip reinforcing rib at desired length.
Bend the conduit to expose the cut and
carefully cut around the conduit without
cutting the wires inside. Remove excess
length.
2) REMOVE CONNECTOR:
Carefully snip the last rib(s) to loosen the
connector from the excess length, then
twist/pull to remove it.
HOW TO TRIM THE CONDUIT: The 6 ft. non-metallic flexible conduit can be trimmed in the field.


Produkt Specifikationer

Mærke: Lowell
Kategori: Ikke kategoriseret
Model: ACS-2010-RPC-HW

Har du brug for hjælp?

Hvis du har brug for hjælp til Lowell ACS-2010-RPC-HW stil et spørgsmål nedenfor, og andre brugere vil svare dig