INTRODUCTION
The TRV10RFM is a battery-powered, mini-size thermostatic radiator valve (TRV)
controller using ZigBee wireless communication. Simply replace the existing,
passive head on the standard radiator valve with the TRV10RFM (referred to from
now on as the unit). Use the unit with the VS10RF or VS20RF series of wireless
thermostats and a Universal Gateway.
VS10RF / VS20RF
Thermostat
(Required)
UG600
(Required)
SALUS Wiring Centre
KL08RF
Checking the compatibility of your heating system
Our RA adapter also ts this valve.
Once tted the RA adapter should look like this.
If you can not see any thread on
the valve and it looks like this
picture, you may be able to use the
RA adapter supplied.
TRV10 ts 30x1,5 mm thread.
Installing the Unit
Screw the units nut (nger
tight) to the radiator valve
and check that the LED is
solid red.
Press any button on the
unit to adapt it to the
radiator valve. Once all
adaptation noise and LED
activity has stopped, the
unit is ready to pair with
your wireless thermostat.
The unit is now ready
for pairing to the SALUS
thermostat. You may now
start the pairing process.
4 5 6
Remove the battery door
on the side of the unit.
Insert the batteries,
ensuring correct
orientation.
1 2 3
The LED on the unit ashes
green then ashes red before
changing to solid red. When
it is solid red, place the unit
over the radiator valve using
the mounting ring if needed:
Contents of the box
For the latest PFD Instruction Manual, go to
www.salus-controls.com
TRV10RFM
2 AA Batteries
Adapter
Manual
Box Contents
Product Compliance
This product is CE compliant and meets the following EC Directives: Electro-Magnetic Compatibility
directive 2014/30/EU; 2014/53/EU and 2011/65/EU.
Safety Information
Use in accordance with the regulations. The unit is to be used for the control of room temperature
inside the house.
Installation
This accessory must be tted by a competent person, and installation must comply with the
guidance, standards and regulations applicable to the country or state where the product is
installed. Failure to comply with the relevant standards could lead to prosecution.
RX10RF
(Optional)
System Overview
To achieve the best control from the unit and thermostat, we recommend they are
used with the SALUS system receiver congured to RX1. The system receiver will
turn the boiler on or o when requested by the thermostat. See your boiler receiver
manual for more information about the RX1 conguration.
+
Up to 6 units can be connected to a VS10RF/VS20RF
The unit is modulating, which means it opens or closes partially
or 100% depending on the relationship between the actual room
temperature and the required room temperature measured by
the VS10/20RF.
Checking the compatibility of your heating system
The SALUS TRV10RFM is compatible with the majority of thermostatic radiator valves.
Before tting, please check your valve is suitable for use with the SALUS TRV.
ValveRemove the TRV head
Note: If all the measurements are as stated on this page then the TRV will t directly
to your valve. Also if your valve is not suitable please consider changing your existing
valves, contact your installer.
Measure the thread diameter
(must measure 30mm)
1
2
mm102030
3
mm1020
Measure the pin length of the valve
when it is in the open position.
(must measure between 13-16mm)
Preparing to Pair the Unit
1
Press and hold the button on the Universal Gateway for
ve seconds. This puts the Universal Gateway in pairing
mode. See your Universal Gateway manual for more
information.
2
Ensure the wireless thermostat is powered up and
ready for pairing. See your thermostat manual for more
information.
3
If you are using the optional RX10RF wireless boiler receiver congured for
remote boiler switching, ensure this has been powered up and the red LED
has gone from ashing to steady. See your boiler receiver manual for more
information.
Pairing the Unit
Press and hold the pairing button for 10 seconds.
You can pair up to 6 units with one thermostat.
Pair the units room by room.
You have paired the unit to the thermostat when the unit LED goes off.
Once paired, the unit operates in automatic mode and receives room temperatures
from the thermostat.
LED Indication
Pairing Button
Manual open/
status indication Manual close/
status indication
Using the Unit
Leaving the Network
Once paired to a thermostat, press and hold the
pairing button on the unit for 10 seconds.
The red LED come on together for one second.
Note: After you have deleted the unit from the
wireless network, you must reinstall the TRV see
Installing the unit.
Press for 3 seconds
to manually open
Press for 3 seconds
to manually close
LED ashes green once and then goes out.
To check status refer to table above.
LED ashes red once and then goes out.
To check status refer to refer to table above.
Short press to return to Auto mode.
Red LED will ash once to conrm that
the unit is in AUTO.
Using the Unit
Auto Lock Function
Auto lock function is disabled until you have gone through the pairing process. After
pairing, the TRV will auto lock after 5 minute if no buttons have been pressed.
Unlocking the Buttons
To unlock the buttons, press the pairing and close buttons together for 3 seconds.
Opening the Valve Manually
Press the open button for 3 seconds. The LED ashes green once and the valve opens.
Closing the Valve Manually
Press the close button for 3 seconds. The LED ashes red once and the valve closes.
Entering Fail Safe Mode
In fail safe mode, the unit opens the valve 25% for water ow to maintain room
temperature.
To enter fail safe mode, press and hold the open and close buttons together for 3 seconds.
To exit fail safe mode, press the:
Pairing button to put the unit in automatic mode
Open button for 3 seconds to open the valve
Close button for 3 seconds to close the valve
Restoring Factory Default Settings
Press the pairing, open, and close buttons together for 10 seconds.
Protecting against Frost
When you have manually closed the valve, the unit automatically enables frost
protection. Frost protection starts only when the temperature in the room drops below
the frost temperature setpoint. The unit does all this automatically when connected to a
thermostat and you don’t have to do anything.
Using the Unit
Detecting Open Windows
The unit checks the rate of temperature drop in the room in which it is located. If the drop
is rapid, it assumes a window in the room has been opened. This only works if the unit is
paired to the thermostat and is in automatic mode and the battery in the unit is not low.
The unit does all this automatically when connected to a thermostat and you don’t have
to do anything. It works between 0 and 40⁰C.
Protecting against Lime Scale
Do not leave a valve open for a long time because this could cause a build up of lime scale.
The unit has a lime-scale protection feature to prevent against this. The valve motor
automatically starts once a week if no valve movement has been detected within a 14-
day period. Lime-scale protection will continue to operate in automatic, manual open,
and manual close modes and you don’t have to do anything.
Auto Adaptation
Once the batteries are inserted into the unit, the red light will appear. If no keys are pressed
it will auto adapt to the valve.
Button Usage
To do this… Press the…
Leave the network Pairing button for 10 seconds (when unit already in network)
Pair with thermostat Pairing button for 10 seconds
Put unit in automatic mode Short press Pairing button
Fully open the valve Open button for 3 seconds
Fully close the valve Close button for 3 seconds
Restore factory default settings Open, pairing, and close buttons together for 3 seconds
Lock and unlock the buttons Pairing and close buttons together for 3 seconds
Wireless Radiator Controller
Model: TRV10RFM
INSTRUCTION M ANUAL
www.salus-controls.com
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road,
Dodworth, Barnsley S75 3SP, UK.
SALES:
T: +44 (0) 1226 323961
E: sales@salus-tech.com
TECHNICAL: T: +44 (0) 1226 323961
E: tech@salus-tech.com
Maintaining a policy of continuous product development, SALUS Controls plc reserves the right to change
specication, design and materials of products listed in this brochure without prior notice.
SALUS Controls is a member of the Computime Group
Issue Date: Dec 2014
00086/2
For PDF Instruction Manual go to
www.salus-controls.com
Technical Detail
SALUS Controls warrants that this product will be free from any defect
in materials or workmanship, and shall perform in accordance with its
specification, for a period of five years from the date of installation.
SALUS Controls sole liability for breach of this warranty will be (at its option)
to repair or replace the defective product.
Warranty
Model TRV10RFM
Type Hydraulic Radiator Valve
DC Motor
M30 x 1.5
LED Indicator Bi-Colour, Red/Green
Valve Adaptation Automatic
Power Source 2x AA Batteries
Battery Life 14 Months (low battery indication)
Control Method Modulating
Communication 2.4GHz ZigBee wireless
Operating Temperature 0 to 45ºC
Storage Temperature -20 to 60ºC
Operating Humidity 5 to 95”RH
Protection IP30
Size (mm) H 88.6, W 51
Manual open/status indication
Manual close/status indication
Pairing
Customer Name: ..................................................................................
Customer Address: ..............................................................................
....................................................... Post Code: ....................................
Tel No: .................................................................................................
Email: ..................................................................................................
Engineers Company: ............................................................................
Tel No: .................................................................................................
Email: ..................................................................................................
Instalation Date: ..................................................................................
Engineers Name: .................................................................................
Engineers Signature: ...........................................................................
To remove the unit from auto mode, follow the steps below. If the buttons
are locked, unlock them by pressing the pairing and close buttons together
for 3 seconds.
Manual Override
LED Indications
100% open
0% open
1 to
100% open
0% open
100% open
0% open
100% open
25% open
Power switched
on or after reset
Unit adapting
to valve
Unit has not
joined network
or has not paired
to thermostat
Unit paired to
thermostat and
in auto mode
Leaving network
Identifying the
network
When... The LEDs... Valve
Software Version
indication
Auto mode
Manual open
Manual close
A sequence of red and green LEDs ashing
displayed indicates the software version
Red ashes then goes steady. Green ashes (or red
asheson failure to adapt). Green steady.
Green and red ash (or red ashes on failure to adapt)
Green and red ash alternately after short press on
open or close button
Green ashes twice after short press on open or
close button
Red ashes twice after short press on open or
close button
No LED
Red and green on together for one second
Green ashes for up to 10 minutes
25% open
100% open
0% open
Wireless
link to
thermostat
lost
Normal
operation
Battery low
Error installing
Auto mode
Manual open
Manual close
Auto mode
Auto mode
Manual open
Manual close
Window open
mode active
Green and red ash alternately after short press on
open or close button
Green ashes twice after short press on open or
close button
Red ashes twice after short press on open or
close button
Green ashes once after short press on open or
close button
Red ashes once after short press on open or
close button
Green ashes twice after short press on open or
close button
Red ashes twice after short press on open or
close button
Green and red ash twice every 10 seconds
Red ashes three times every 10 seconds
(less if the battery is low)
Green and red ash alternately
Input Three push buttons:


Produkt Specifikationer

Mærke: Salus
Kategori: Smart hjem
Model: TRV10RFM

Har du brug for hjælp?

Hvis du har brug for hjælp til Salus TRV10RFM stil et spørgsmål nedenfor, og andre brugere vil svare dig