CDN IN1022 Manual

CDN Termometer IN1022

Læs gratis den danske manual til CDN IN1022 (5 sider) i kategorien Termometer. Denne vejledning er vurderet som hjælpsom af 2 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 1.5 anmeldelser. Har du et spørgsmål om CDN IN1022, eller vil du spørge andre brugere om produktet?

Side 1/5
Perfect For
•Non-contactsurfacetemperatures
Easy To Use
•1-secondresponse
•8-beamlasertargetillumination
•Backlit
•Data-hold
•One-buttonoperation
Features
•Memory
•Maximum,minimum,difference,averagewithlockfor
continuousscanning
•Highandlowalerts
•Distance:spot=12:1
•Batterystatusindication
•ABSplastic
•Auto-off
•Batteriesandinstructionsincluded
Get Professional Results
Every Time!
Monitoringtemperatureisessentialtokeepingfood
safe.TheversatileIN1022isperfectforanyapplication.
Simplypointtheinfraredsensorlenstowardthetarget
andpressthetriggertogetaquickreadingofsurface
temperatures.
Maximum, Minimum, Difference
and Average Modes
TheIN1022alsooffersMaximum,Minimum,Difference
andAveragemodes.Maximummodedisplaysthehighest
temperatureamongmultipletargets.Minimummode
displaysthelowesttemperatureamongmultipletargets.
Differencemodedisplaysthedifferencebetweenthe
maximumandminimumtemperaturemeasurements
ofmultipletargets.WhileAveragemodedisplaysthe
averagetemperaturemeasurementsofmultipletargets.
Lock Mode
Lockmodecontinuouslymeasuresthetemperature
forupto60minutes.Thisisparticularlyusefulfor
continuoustemperaturemonitoring.
High and Low Alerts
TheIN1022providesaprogrammablehighandlowalert
formeasurementsthatareoutofthedesiredrange.
Note:Removestickerfromdisplaybeforeuse.
Note:Inthefollowinginstructions,namesofthecontrol
buttonsareshowninCAPS.Functioninformationthatappears
onthedisplayisshowninBOLD CAPS.
Battery Installation
ReplacebatterywhenLCDbecomesdimoralarm
leveldeclines.Powerofftheunitbeforeinstallingthe
batteries.Amalfunctionmayoccurifthepowerison
whenthebatteryisinstalled.Ifamalfunctionoccurs,
restartthedevice.
1. Removebatterycoverbyslidingitinthedirectionof
thearrow.
2. Installtwo1.5VAAAbatteriesobservingpolarity
shownincompartment.
3. Replacethebatterycoveruntilitclicksshut.
Model: IN1022
Infrared Gun
-76to+1022°F/-60to+550°C
Operating Instructions
Mode Selection: E
Ø
Eâ á
Ø
MAX
Ø
MIN
Ø
DIF
Ø
AVG
Ø
HAL
Ø
LAL
A. Temperature Scale
ToselecttemperaturereadinginFahrenheit
orCelsius:
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. Pressthe°C/°Fbuttontochangethescale.
B. Backlit Display
Toturnthebacklitdisplayonandoff:
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. Pressandholdthetriggerandthenalsopress
theLOCKbuttontoturnthebacklitdisplayonand
off.TheBACKLIGHT icon( )appearsinthetop
portionofthedisplaywhenon.
C. Laser Light
Toturnthelaserlightonandoff:
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. Pressandholdthetriggerandthenalsopressthe
C°/F°buttontoturnthelaserlightonandoff.The
LASER icon( )appearsinthetopportionofthe
displaywhenon.
E. Lock Mode
Thisisparticularlyusefulforcontinuoustemperature
monitoringforupto60minutesandcanbeusedwith
Minimum,Maximum,DifferenceandAveragemodes.
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. PresstheLOCKbutton. appearsinthetopLOCK
portionofthedisplaywhenon.
3. Thethermometercontinuouslydisplaysthe
temperatureforupto60minutesorrestartsthe
timeifthetriggerispressedagain.
F. Infrared Thermometer
Note:TheIN1022isintendedforfoodserviceuse—donotusefor
safetyrelatedapplications.
1. Infrared Scanning
1. Distance:Spot = 12:1
Forexample,ifthesurface
areabeingmeasuredis
10"indiameter,thenthethermometermustbe
within120"ofthetargetforanaccuratereading.
2. Aimtheinfraredlensatthetargetandpress
thetriggertodisplaythesurfacetemperature.
Ifon,thelaserlightautomaticallyilluminates
thetarget.
3. The8-beamlaserlightformsacirclethatdenes
theareaofmeasure.Makesurethecircleis
smallerthantheareabeingmeasured.Ifthe
laserlightcircleislargerthantheareabeing
measured,thereadingwillincludeambient
temperaturesandmakethereadinginaccurate.
4. Measurementcontinuesaslongasthetriggeris
pressed.Thenewestreadingupdatesthedisplay.
5. Whenthetriggerisreleased, appearsonHOLD
thedisplayandthelastreadingremainsvisible
for60secondsbeforetheunitautomatically
powersoff.
2. Emissivity
Everythinggivesoffacertainamountofradiation.
Emissivityisthemeasureofthisthermalradiation.
Theinfraredthermometerissuppliedwithadefault
emissivityof0.95,whichstandardformostuses.
Theemissivityofthethermometercanbechanged
from0.1(10E)to1(100E).Only experienced
personnel should attempt to make changes.
Forinformationrelatingtotheemissivityofspecic
materials,pleasecontactCDN.
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. PresstheMODEbuttonuntil appearsintheE
lowerleftcornerofthedisplay.Thecurrent
emissivitysettingappearsinthelowerright
cornerofthedisplay
3. PresstheMODEbuttonagaintoadjustthe
emissivityvaluein0.01(1E)incrementsinthe
EmissivityEditMode.âEáappearsinthelower
leftcornerofthedisplay.
4. Pressthe°C/°Fbuttontodecreasethe
emissivityvalue.PresstheLOCKbuttonto
increasetheemissivityvalue.Pressandholdfor
fastadvance.
5. PresstheMODEbuttonagaintoexitEmissivity
EditModeandenterMAXMode.
Note:Non-contactinfraredthermometersarenot
recommendedforuseinmeasuringthetemperatureof
shinyorpolishedmetals.
3. Maximum Mode
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. PresstheMODEbuttonrepeatedlyuntilMAX
appearsinthelowerleftportionofthedisplay.
3. Aimtheinfraredlensatthetargetandpressthe
triggertodisplaythesurfacetemperature.
4. Measurementcontinuesaslongasthetrigger
ispressedorfor60minutesinLockMode.
TheMAXreadingdisplaysthehighest
temperatureamongmultipletargets.
4. Minimum Mode
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. PresstheMODEbuttonrepeatedlyuntilMIN
Distance:Spot(FOV)=12:1
Emissivity=0.1~1,Step.01
WaveLength=8µm-14µm
CAUTION: Never point the unit and/or laser towards
anyone’s eyes. Do not look directly into the laser
beams permanent eye damage may result. Keep
away from children.


Produkt Specifikationer

Mærke: CDN
Kategori: Termometer
Model: IN1022

Har du brug for hjælp?

Hvis du har brug for hjælp til CDN IN1022 stil et spørgsmål nedenfor, og andre brugere vil svare dig