CDN ProAccurate INTP662 Manual

CDN Termometer ProAccurate INTP662

Læs gratis den danske manual til CDN ProAccurate INTP662 (5 sider) i kategorien Termometer. Denne vejledning er vurderet som hjælpsom af 7 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 4 anmeldelser. Har du et spørgsmål om CDN ProAccurate INTP662, eller vil du spørge andre brugere om produktet?

Side 1/5
for non-contact and internal temperatures
•NSF
®
Certified
•1&3secondresponses
•1.5mmthintip
•3.75”(9.53cm)probe
•Infraredfornon-contactsurfacetemperatures
•Thermocoupleprobeforinternaltemperatures
•Maximum,minimumandlockmodesforcontinuous
scanning
•8-beamlasertargetillumination
•Distance:Spot=8:1
•Data-hold
•One-buttonoperation
•BacklitHACCPchecklights
•Batterystatusindication
•Food-safeABSplasticwithBioCote
®
•Stainlesssteelprobe
•Auto-off
•Batteryandinstructionsincluded
Get Professional Results
Every Time!
Monitoringtemperatureisessentialtokeepingfoodsafe.
TheversatileINTP662isapowerhousekitchentool.
Simplypointtheinfraredguntowardthetargetandpress
thetriggertogetaquickreadingofsurfacetemperatures
orflipdowntherapid-responsethermocoupleprobeto
measureinternaltemperatures.IntegratedHACCPcheck
backlightinginstantlyshowsiftemperaturesarewithin
HACCPguidelinesforsafefoodtemperatures.
Minimum, Maximum and Lock
TheINTP662alsooffersMinimum,Maximum,andLock
modes.Minimummodedisplaysthelowesttemperature
amongmultipletargets.Maximummodedisplaysthe
highesttemperatureamongmultipletargets.WhileLock
modecontinuouslydisplaysthetemperatureforupto
60minutes.Thisisparticularlyusefulforcontinuous
temperaturemonitoring.
Note:Removestickerfromdisplaybeforeuse.Cleanthe
thermometerprobebeforeeachuse.
Important: DO NOT LEAVE THERMOMETER IN HOT OVEN.
HAND WASH AND DRY. DO NOT IMMERSE HOUSING IN
LIQUID.
Note:Inthefollowinginstructions,namesofthecontrol
buttonsareshowninCAPS.Functioninformationthat
appearsonthedisplayisshownin .BOLD CAPS
Battery Installation
ReplacebatterywhenLCDbecomesdim.Poweroffthe
unitbeforeinstallingthebatteries.Amalfunctionmay
occurifthepowerisonwhenthebatteryisinstalled.Ifa
malfunctionoccurs,restartthedevice.
1. Removebatterycoverbyslidingitdownalongthe
handle.
2. Installtwo1.5VAAAbatteriesobservingpolarity
shownincompartment.
3. Replacethebatterycoveruntilitclicksshut.
Model: INTP662
ProAccurate
®
Infrared Gun/
Thermocouple Thermometer
Infrared:-76to+662°F/-60to+350°C
Thermocouple:-76to+662°F/-60to+350°C
Operating Instructions
Mode Selection:MINØ Ø ØMAX LOCK °C/°FØEMIS
A. Temperature Scale
ToselecttemperaturereadinginFahrenheitorCelsius:
1. Pressthetriggertoturnthethermometeron.
2. PresstheMODEbuttonfourtimes.The°F or °C
symbolflashesonthedisplay.
3. PresstheSCANbuttontochangethescale.
B. Infrared Thermometer
InfraredisthedefaultmodeoftheINTP662.
Note:TheINTP662isintendedforfoodserviceuse—donotuse
forsafetyrelatedapplications.
1. Infrared Scanning
a. Distance:Spot = 8:1
Forexample,ifthe
surfaceareabeing
measuredis10"in
diameter,thenthethermometermustbewithin
80"ofthetargetforanaccuratereading.
b. Aimtheinfraredlensatthetargetandpress
thetriggertodisplaythesurfacetemperature.
The8-beamlaserlightautomaticallyilluminates
thetarget,specifyingtheapproximate
measurementareaforbettertargeting.
c. The8-beamlaserlightformsacirclethat
definestheareaofmeasure.Makesurethe
circleissmallerthantheareabeingmeasured.
Ifthelaserlightcircleislargerthanthearea
beingmeasured,thereadingwillincludeambient
temperaturesandmakethereadinginaccurate.
d. Measurementcontinuesaslongasthetrigger
ispressed.Thenewestreadingupdatesthe
display.
e. Whenthetriggerisreleased,HOLD appears on
thedisplayandthelastreadingremainsvisible
for15secondsbeforetheunitautomatically
powersoff.
2. Minimum Mode
a. Pressthetriggertoturnthethermometeron.
b. PresstheMODEbuttononce. flashesonMIN
thedisplay.
c. PressthetriggertoconfirmtheMinimumMode
anddisplaythelowesttemperatureamong
multipletargets. remainsonthedisplay.MIN
d.Thethermometercontinuestodisplaythe
minimumreadingduringeachmeasurement
perioduntiltheMODEbuttonispressedagainor
theunitpowersoff.
3. Maximum Mode
a. Pressthetriggertoturnthethermometeron.
b. PresstheMODEbuttontwice. flashesonMAX
thedisplay.
c. PressthetriggertoconfirmtheMaximumMode
anddisplaythehighesttemperatureamong
multipletargets. remainsonthedisplay.MAX
d.Thethermometercontinuestodisplaythe
maximumreadingduringeachmeasurement
perioduntiltheMODEbuttonispressedagain
ortheunitpowersoff.
4. Lock Mode
Thisisparticularlyusefulforcontinuous
temperaturemonitoring.
a. Pressthetriggertoturnthethermometeron.
b. PresstheMODEbuttonthreetimes.LOCK
flashesonthedisplay.
c. PressthetriggertoconfirmtheLockMode.
The°F or °Csymbolflashesonthedisplay.
d. Thethermometercontinuouslydisplaysthe
temperatureforupto60minutesoruntilthe
triggerispressedagain.
5. Emissivity
Everythinggivesoffacertainamountofradiation.
Emissivityisthemeasureofthisthermalradiation.
Theinfraredthermometerissuppliedwithadefault
emissivityof0.95,whichstandardformostuses.
Theemissivityofthethermometercanbechanged
from0.10(10E)to1(100E).Only experienced
personnel should attempt to make changes.
Forinformationrelatingtotheemissivityofspecific
materials,pleasecontactCDN.
a. Pressthetriggertoturnthethermometeron.
b. PresstheMODEbuttonfivetimestoenter
EmissivityMode. flashesonthedisplay.95E
c. Pressthetriggertoadjusttheemissivityvalue
in0.01(1E)increments.
d. PresstheMODEbuttonagaintoexit
EmissivityMode.
Note:Non-contactinfraredthermometersarenot
recommendedforuseinmeasuringthetemperatureof
shinyorpolishedmetals.
6. Error Messages
TheINTP662incorporatesvisualdiagnostic
messagesasfollows:
a. HI LO or isdisplayedwhenthetemperature
beingmeasuredisoutsidetheinfraredrange
oftheinstrument.
1.)HI indicatesthatthetemperatureishigher
than+662°F/+350°C.
2.)LO indicatesthatthetemperatureis
lowerthan-76°F/–60°C.
b. Allowaminimum30minutesforthe
thermometertostabilizetotheworking/room
temperature.
Distance:Spot(FOV)=8:1
Emissivity=0.1~1,Step.01
WaveLength=8~14µm
CAUT ION: Never point the unit and/or las er toward s
anyone’s eyes. Do not look directly into the laser
beam s permanent eye damage may result. Keep
away from children.


Produkt Specifikationer

Mærke: CDN
Kategori: Termometer
Model: ProAccurate INTP662

Har du brug for hjælp?

Hvis du har brug for hjælp til CDN ProAccurate INTP662 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termometer CDN Manualer

CDN

CDN DTP392 Manual

15 Juni 2025
CDN

CDN DTL572 Manual

14 Juni 2025
CDN

CDN TCF400 Manual

14 Juni 2025
CDN

CDN IN1022 Manual

14 Juni 2025
CDN

CDN IN482 Manual

14 Juni 2025
CDN

CDN DTC450 Manual

14 Juni 2025
CDN

CDN TCG400 Manual

13 Juni 2025
CDN

CDN TCH130 Manual

13 Juni 2025

Termometer Manualer

Nyeste Termometer Manualer