Thermostat Application Guide
Description
Gas or Oil Heat
Electric Furnace
Heat Pump (With Aux. or Emergency Heat)
Multi-Stage Systems
Heat Only Systems
Cool Only Systems
Millivolt
Yes
No
No
Yes
Yes
Yes
Power Type
Battery Power
Hardwire (Common Wire)
Hardwire (Common Wire) with
Battery Backup
Table of Contents
Installation Tips
Thermostat Quick Reference
Wiring
Wiring Diagrams
Technician Setup Menu
Programming
Features
Specications
Page
A trained, experienced
technician must install this
product.
Carefully read these
instructions. You could damage
this product or cause a
hazardous condition if you fail
to follow these instructions.
Una version en espanol de este
manual se puede descargar en
la pagina web de la compania.
U.S. Registered Trademark. Patents pending
Copyright 2019 All Rights Reserved.
5-8
13-17
1
1
1
1
2-4
Yes
Yes
Mount Thermostat
Align the 4 tabs on the subbase with
corresponding slots on the back of the
thermostat, then push gently until the
thermostat snaps in place.
Installation Tips
2
2
2
2
Note: To ensure a solid t between the
thermostat and the subbase:
1. Mount subbase to a at wall
2. Use screws provided
3. Drywall anchors should be ush with the wall
4. Wires should be pushed into the wall
Installation Tips
The thermostat should be installed approximately 4 to 5 feet above the
oor. Select an area with average temperature and good air circulation.
• Close to hot or cold air ducts
That are in direct sunlight
With an outside wall behind the thermostat
• In areas that do not require conditioning
Where there are dead spots or drafts (in corners or behind doors)
Where there might be concealed chimneys or pipes
Wall Locations
Pick an installation location that is easy for the user to access. The temperature
of the location should be representative of the building.
Installation Tip
Do not install thermostat in these locations:
3
3
3
3
4
4
4
4
Installation Tips
18-22
23
Vertical Mount
Horizontal Mount
For horizontal mount put one screw on
the left and one screw on the right.
All of our products are mercury free. However, if the product you are
replacing contains mercury, dispose of it properly. Your local waste
management authority can give you instructions on recycling and
proper disposal.
Mercury Notice
Failure to disconnect the power before beginning to install this product
can cause electrical shock or equipment damage.
Installation Tip: Electrical Hazard
For vertical mount put one screw on
the top and one screw on the bottom.
Subbase Installation
11-12
9-10
P.O. Box 3377
Springeld, MO 65808-3377
24
Rev. 1915
T805
Terminal Designations
This thermostat is shipped from the factory to operate a conventional heating
and cooling system. This thermostat may also be congured for a heat pump
system.
Wiring
Terminal
1 Heat 1 Cool
Conventional
System
RC
RH
C
B
O
G
W
Y
Transformer power
(cooling)
Transformer power
(heating)
Transformer
common
Fan relay
Heat Relay
Compressor
Relay
Wiring
Caution:
Electrical Hazard
All components of the control
system and the thermostat
installation must conform to
Class II circuits per the NEC Code.
Warning:
Do not overtighten terminal
block screws, as this can
damage the terminal block.
A damaged terminal block
can keep the thermostat
from tting on the subbase
correctly or cause system
operation issues.
Installation Tip
Max Torque = 6in-lbs.
Wiring
If you are replacing a thermostat,
make note of the terminal
connections on the thermostat that
is being replaced. In some cases
the wiring connections will not be
color coded. For example, the
green wire may not be connected
to the terminal.G
Loosen the terminal block screws.
Insert wires then retighten the
terminal block screws.
Place nonammable insulation into
the wall opening to prevent drafts.
1.
2.
3.
Wiring Tips
C Terminal
The C (common wire) terminal does
not have to be connected when the
thermostat is powered by batteries.
Wire Specications
Use shielded or non-shielded 18-22
gauge thermostat wire.
Failure to disconnect the power
before beginning to install this
product can cause electrical shock
or equipment damage.
Thermostat Quick Reference
Displays the current room temperature
Time and day of the week
Setpoint: Displays the user selectable setpoint temperature.
Hold: is displayed when the thermostat program is permanently overridden.
System Operation Indicators:
If these or the Fan indicator are ashing, it means that the system is in a
delay of some type (compressor delay, cooling fan delay, staging delay).
Low Battery Indicator: Replace batteries when this indicator is shown.
Program Menu Options: Show dierent options during programming.
Program Time Periods - Residential: Uses 4 time periods - WAKE, RETURN,
LEAVE & SLEEP.
Getting to know your thermostat
Thermostat Quick Reference
5
5
5
5
6
6
6
6
9
9
9
9
10
10
10
10
Battery Installation
Battery installation is recommended even if the thermostat is
hardwired (C terminal connected). When the thermostat is hardwired
and batteries are installed, the thermostat will activate a compressor
delay of 5 minutes when it detects a power outage from the hardwired
power supply.
Important:
High quality alkaline batteries are recommended.
Rechargeable batteries or low quality batteries
do not guarantee a 1-year life span.
Insert 2 AA Alkaline batteries
(included). High quality alkaline
batteries are recommended.
Simple operating instructions
are found on the back of the
battery door.
To release battery cover press nger bevel
on the left side and lift the cover to access
batteries.
Keypad Lockout: Lock the thermostat
N/A
Energy Ecient Globe: Indicates ecient setpoint temperature.
N/A
1 Heat 1 Cool
Heat Pump
System
Transformer power
(cooling)
Transformer power
(heating)
Transformer
common
Changeover valve
energized in cooling
Changeover valve
energized in heating
Fan relay
N/A
1st Stage of heat
and cool


Produkt Specifikationer

Mærke: Pro1
Kategori: Termostat
Model: T805

Har du brug for hjælp?

Hvis du har brug for hjælp til Pro1 T805 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termostat Pro1 Manualer

Pro1

Pro1 T721 Manual

20 August 2025
Pro1

Pro1 T731WO Manual

20 August 2025
Pro1

Pro1 R251S Manual

20 August 2025
Pro1

Pro1 T805 Manual

20 August 2025
Pro1

Pro1 T701i Manual

20 August 2025
Pro1

Pro1 T721i Manual

20 August 2025
Pro1

Pro1 E219 Manual

20 August 2025
Pro1

Pro1 T701 Manual

20 August 2025
Pro1

Pro1 T755S Manual

20 August 2025
Pro1

Pro1 T501M Manual

20 August 2025

Termostat Manualer

Nyeste Termostat Manualer