WyreStorm EX-70-H2X Manual

WyreStorm Modtager EX-70-H2X

Læs gratis den danske manual til WyreStorm EX-70-H2X (4 sider) i kategorien Modtager. Denne vejledning er vurderet som hjælpsom af 17 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 9 anmeldelser. Har du et spørgsmål om WyreStorm EX-70-H2X, eller vil du spørge andre brugere om produktet?

Side 1/4
4K UHD 4:4:4/60 HDBaseT extender with HDMI Loop Out
and 2-way PoH (70m/230ft)
EX-70-H2X Quickstart Guide
Copyright © 2018 WyreStorm Technologies | wyrestorm.com
EX-70-H2X v2 Quickstart Guide | 181023
UK: +44 (0) 1793 230 343 | ROW: 844.280.WYRE (9973)
support@wyrestorm.com
1 of 4
WyreStorm recommends reading through this document in its entirety to become familiar with the product’s features prior to starting the
installation process.
Basic Wiring Diagram
HDMI Source
HDMI
HDBaseT Cat5e/6/6a
IR Emitter
IR Emitter
IR Receiver
HDMI Display
12 DC
Power Supply
12 DC
Power Supply
KEY
HDMI
HDBaseT/Ethernet
IR/RS-232
Power
EX-70-H2X Transmitter (TX) EX-70-H2X Receiver (RX)
HDMI Ethernet
Ethernet
IR to Control System Router
CAB-IR-LINK (Sold Separately)
HDMI
Note: Extender set may be powered
by either the TX or RX. Only one
power supply is required.
Note: Extender set may be powered
by either the TX or RX. Only one
power supply is required.
HDMI Display
OR
IMPORTANT! Installation Requirements
This product was released in 2 different versions which contain
different chassis designs and feature sets. This Quickstart Guide
contains information for version 2 of this product only. See Identifying
Product Versions for details.
Visit the product page to download the latest rmware, document
version, additional documentation, and conguration tools.
Read through the section for important wiring Wiring and Connections
guidelines before creating or choosing premade cables.
While this product supports CEC, WyreStorm cannot guarantee
compatibility with all forms of CEC communication.
In the Box
1x EX-70-H2X Transmitter
1x EX-70-H2X Receiver
1x 12V DC 3A Power Supply (US | UK | EU)
2x 3-pin Screw Down Phoenix Connectors
1x IR Emitters
1x IR Receivers
4x Mounting Brackets (2x for TX | 2x for RX)
1x Quickstart Guide (this document)
Identifying Product Versions
This product has been released with different versions which contain different chassis designs and/or feature sets. This Quickstart Guide contains information
for version 2 of this product only, information for version 1 can be found in the previous Quickstart Guide. Versions can be identied by a v# after the model
number on the product chassis model sticker. Note that version 1 of this product may not contain a v1 after the product while all versions above version 1 will
contain a version number.
Copyright © 2018 WyreStorm Technologies | wyrestorm.com
EX-70-H2X v2 Quickstart Guide | 181023
UK: +44 (0) 1793 230 343 | ROW: 844.280.WYRE (9973)
support@wyrestorm.com
2 of 4
Wiring and Connections
WyreStorm recommends that all wiring for the installation is run and terminated prior to making connections to the switcher. Read through this section in it’s
entirety before running or terminating the wires to ensure proper operation and to avoid damaging equipment.
IMPORTANT! Wiring Guidelines
The use of patch panels, wall plates, cable extenders, kinks in cables, and
electrical or environmental interference will have an adverse effect on
signal transmission which may limit performance. Steps should be taken
to minimize or remove these factors completely during installation for best
results.
WyreStorm recommends using pre-terminated HDMI cables due to the
complexity of these connector types. Using pre-terminated cables will
ensure that these connections are accurate and will not interfere with the
performance of the product.
IR TX/RX Guidelines
Using WyreStorm infrared emitters and receivers is the best way to ensure
that most IR coding formats are transmitted and received Other 3rd party
emitters and receivers can be used; however, these devices must operate in
the same manner as the WyreStorm devices.
Due to differences in IR across 3rd party control systems their IR ports
should never be connected directly to a WyreStorm system as an
incompatibility may exist. WyreStorm offers a cable that compensates for
voltage differences as well adjusts for differences in the pins used within the
port. Refer to the product page for more information.CAB-IR-LINK
IR TX Port Pinout
Connection for IR TX (transmit) uses a 3.5mm (1/8in) mono plug.
Tip: Anode
Sleeve: Cathode (IR Signal)
IR RX Port Pinout
Connection for IR RX (receive) uses a 3.5mm (1/8in) stereo jack that outputs
+5V DC to power the included IR receiver.
Tip:
Ring: IR Signal
+5V DC
Sleeve: Ground (GND)
RS-232 Wiring
The EX-70-H2X uses a 3-pin RS-232 with no hardware ow control. Most
control systems and computers are DTE where pin 2 is RX, this can vary from
device to device. Refer to the documentation for the connected device for pin
functionally to ensure that the correct connections can be made.
Refer to for details on setting RS-232 modes.RS-232 Mode Settings
3rd Party Device
Pin 1 TX (Transmit) > To > RX (Receive)--- ---
Pin 2 RX (Receive) > To > TX (Transmit)--- ---
Pin 3 G (Gro d) > To > G (Gro d)un --- --- un
WyreStorm Co ectornn


Produkt Specifikationer

Mærke: WyreStorm
Kategori: Modtager
Model: EX-70-H2X

Har du brug for hjælp?

Hvis du har brug for hjælp til WyreStorm EX-70-H2X stil et spørgsmål nedenfor, og andre brugere vil svare dig